Fluid Refractometer LB-15FRR

Fluid Refractometer LB-15FRR

Fluid Refractometer LB-15FRR is equipped with automatic temperature compensation(ATC) that adjusts itself to correct temperature discrepancies during usage. Antifreeze, battery, and cleaning fluids are detected. It features a vivid and sharp reticle chart for easy and comfortable reading. Use ambient light and no batteries are needed.

Buy Now Download Catalog

Specifications

Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Weight 165 g

Features

  • Manual calibration (mini-screw driver provided)
  • Aluminum construction(Heavy-duty and lightweight)
  • Easy to focus and calibrate
  • Cushioned with soft & comfortable non-slip rubber
  • Extremely easy-to-use and calibrate

Applications

Fluid Refractometer LB-15FRR is used to test the concentration of ethylene glycol or propylene glycol in antifreeze liquids

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Add a review

Fluid Refractometer

Fluid Refractometer : Fluid Refractometer LB-11FRR
Measurement Range Ethylene Glycol: -60°C to 0°C (0 to 66.6 %)
Propylene Glycol: -50°C to 0°C (0 to 62.4 %)
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Fluid Refractometer : Fluid Refractometer LB-13FRR
Measurement Range Ethylene Glycol: - 60 °F to 32 °F/-50°C to 0 °C
Propylene: - 60°F to 32 °F /-50°C to 0 °C
Battery Fluids: 1.10-1.40 sg
Minimum Division Ethylene Glycol: 10°F/ 5°C
Propylene: 10°F/ 5°C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 10 °F/ ± 5 °C
Propylene Glycol: ± 10 °F/ ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Fluid Refractometer : Fluid Refractometer LB-14FRR
Measurement Range Ethylene Glycol: -50°C to 0 °C
Propylene: -50°C to 0 °C
C: -40°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene: 1°C
C: 5 °C
Battery Fluids: 0.01sg
Accuracy Ethylene Glycol: ± 1 °C
Propylene Glycol: ± 1 °C
C: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm
Fluid Refractometer : Fluids Refractometers LB-10FRR
Measurement Range Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Ethylene Glycol: 1°C
Propylene Glycol: 1°C
Battery Fluids: 0.01 sg
Accuracy Ethylene Glycol: ± 1°C
Propylene Glycol: ± 1°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Fluid Refractometer : Fluid Refractometer LB-17FRR
Measurement Range Urea: 30% to 35%
Ethylene Glycol: -50°C to 0°C
Propylene Glycol: -50°C to 0°C
Cleaning Fluids: -40°C to 10°C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Urea: 0.5°C
Ethylene Glycol: 5°C
Propylene Glycol: 5°C
Cleaning Fluids: 5°C
Battery Fluids: 0.01 sg
Accuracy Urea: ± 0.5°C
Ethylene Glycol: ± 5°C
Propylene Glycol: ± 5°C
Cleaning Fluids: ± 5°C
Battery Fluids: ± 0.01 sg
Dimension (Length) 200 mm
Fluid Refractometer : Fluid Refractometer LB-16FRR
Measurement Range Density: 0 to 100%
Ethylene Glycol: -60°C to 0 °C
Battery Fluids: 1.100 to 1.400 sg
Minimum Division Density: 0.05
Ethylene Glycol: 5 °C
Battery Fluids: 0.01sg
Accuracy Density: ± 5 %
Ethylene Glycol: ± 5 °C
Battery Fluids: ± 0.01 sg
Length 200 mm

Our salinity refractometer is a specialized optical instrument used to measure the concentration of salt in water or other aqueous solutions. It operates by analyzing the refractive index of the sample, which changes with the salt content. These compact and portable devices are equipped with a sample well, precision optics, and a clear scale, allowing for quick and accurate measurements of salinity. Salinity refractometers are crucial tools in various applications, including marine biology, aquarium maintenance, environmental monitoring, and the food industry, ensuring the appropriate salt levels in water for specific purposes and helping maintain the health and safety of aquatic environments and the quality of saline solutions in industrial processes.

Measurement range 0 % ~ 28 % Salinity
Minimum division 0.2 % Salinity
Accuracy ± 0.2 %
Dimension 30 x 40 x 205 mm
Measurement range 0 % ~40 ‰ salinity (ppt) 1.000 ~ 1.030 SG
Minimum division 1 ‰ ppt
Accuracy ± 0.001 SG
Dimension 30 x 40 x 205 mm
Measurement range 0 % ~ 28 %Salinity 0 ~32 % Brix
Minimum division 0.002
Accuracy ± 0.2 %
Dimension 30 x 40 x 205 mm
Measurement range 0 % ~ 100 ‰ Salinity 1.000 ~ 1.070 SG
Minimum division 1 % Salinity 0.001 SG
Accuracy ± 1 % ± 0.001 SG
Dimension 30 x 40 x 205 mm

Our Adblue (or Diesel Exhaust Fluid) refractometer is a specialized optical device used primarily in the automotive and transportation industry to measure the concentration of urea in Adblue, a diesel engine exhaust fluid. It operates by analyzing the refractive index of the fluid, which is directly proportional to the urea concentration. These refractometers are essential tools for ensuring the correct mixture of Adblue, which is critical for reducing emissions and meeting emissions standards in diesel vehicles. They provide precise measurements, allowing users to maintain the optimal urea concentration to effectively reduce harmful nitrogen oxide (NOx) emissions, making them indispensable for fleet maintenance, automotive repair, and compliance with environmental regulations.

Measurement Range 0 % ~ 40 %
Minimum division 0.002
Accuracy ± 0.2 %

Our portable refractometers are compact and versatile optical instruments used for measuring the refractive index of liquids, offering quick and precise insights into the composition and concentration of various samples. Designed for on-the-go or field applications, these handheld devices feature a sample well, precise optics, and a user-friendly interface, making them ideal for use in diverse industries such as food and beverage, agriculture, automotive, and pharmaceuticals. They enable quality control, process monitoring, and quick assessments of sample properties, such as sugar content, concentration, and purity, with ease and efficiency.

Brix range
Salinity range
Serum 0 g/dL ~ 12 g/dL
Urine 1.000 ~ 1.050
Brix range
Salinity range
Serum
Urine
Brix range
Salinity range
Serum
Urine
Brix range
Salinity range
Serum
Urine

Labotronics beer brewing refractometer is a specialized optical instrument designed for the brewing industry, allowing brewers to measure the sugar content, often expressed as Brix, in wort during the brewing process. It operates by measuring the refractive index of the wort due to its sugar concentration, which provides insights into the potential alcohol content and fermentation progress. By offering real-time Brix readings, brewers can monitor the sugar conversion and make precise adjustments to ensure the desired alcohol level and flavor in the final beer. These refractometers are indispensable tools for homebrewers and professional brewers, helping them optimize the brewing process, enhance quality control, and produce beer with consistent and desired characteristics.

Measurement range Brix:0 % - 32 % Wort SG:1.000-1.120
Minimum division Brix: 0.1 % Wort SG: 0.001sg
Accuracy Brix: 0.1 % Wort SG: 0.001sg
Dimension 30 × 40 × 170 mm

We provide benchtop refractometer, a versatile laboratory instrument used for measuring the refractive index of liquids, offering precise insights into their composition, concentration, and purity. It typically features a compact design suitable for laboratory countertops and workbenches, equipped with a sample well, light source, and a user-friendly interface. Our benchtop refractometers are essential tools for researchers and professionals, facilitating rapid and non-destructive analysis of liquid samples to ensure product quality and compliance with industry standards.

Measuring range 1.3000 Nd ~ 1.7000 Nd
Stability of temperature control RT
Temperature control
Temperature control range RT
Measuring range 1.30000 Nd ~ 1.70000 Nd
Stability of temperature control ± 0.01 ℃
Temperature control Built-in semiconductor
Temperature control range 5 ℃ ~ 90 ℃
Measuring range 1.3000 Nd ~ 1.7000 Nd
Stability of temperature control ± 0.03 ℃
Temperature control Built-in semiconductor
Temperature control range 5 ℃ ~ 65 ℃
Measuring range 1.30000 Nd ~ 1.70000 Nd
Stability of temperature control ± 0.02 ℃
Temperature control Built-in semiconductor
Temperature control range 5 ℃ ~ 65 ℃
WhatsApp
×