Freezing Point Tester LB-11FPT is designed to measure coolant freezing points within a temperature range of -70 to 30°C. It includes a 12-liter cold bath with an integrated stirring motor operating at 80 rpm, ensuring uniform temperature distribution. Our freezing point tester complies with ASTM D1177 and SH/T0090-91 standards. It features a 7-inch color touch screen for easy operation and offers a user-friendly interface.
Buy Now Download Catalog Product ManualSpecifications
Temperature Range | - 70 to 30°C |
Temperature Accuracy | 0. 1°C |
Cold Bath Capacity | 12 L |
Motor Stirring Speed | 80 rpm |
Heating Power | 600 W |
Cooling Power | 800 W |
Stirring Motor Power | AC220V/ 10 W |
Power Supply | AC 220V ±10% 50 Hz |
Dimensions | 950 × 750 × 800mm |
Weight | 95 kg |
Features
Applications
Freezing Point Tester is used for measuring engine coolant freezing points in automotive service centers, antifreeze manufacturing, petrochemical industries, research labs, and cold weather testing.
Standard Accessories
Test bottle rubber stopperWhat our customers say
Fatima Jahaf
4 months ago
Eng. Asma Hammad
1 year ago
Mayank Bansal
3 months ago
Mirza Afzal Ali
1 year ago
Thang .
11 months ago
Venkat M
10 months ago
Lokesh Verma
10 months ago
Dylan Redwood
1 year ago
Taras Delenko
1 month ago
Syed Farhan Khursheed
1 year ago
MIRZA AFZAL ALI
2 years ago
Daniel Nkole
10 months ago
Ankit Agrawal
6 months ago
Mahesh Rashinkar
2 months ago
Kadar Basha
1 year ago
Add a review
Cold trough temperature range | 20 °C to -70 °C |
Temperature accuracy | ± 0.5 °C |
Cooling system | Refrigeration compressor |
Sample stirring | 0 beats/min ~ 120 beats/min |
Working Cold Bath | A double-layer vacuum glass bath |
Temperature Range | - 30 ℃ to 80 ℃ |
Temperature Accuracy | ± 0.1 ℃ (customizable ± 0.01 ℃) |
Refrigeration Method | New-type compressor refrigeration |
Our TAN (Total Acid Number) and TBN (Total Base Number) tester is a specialized instrument widely used in the petroleum and lubricant industry for assessing the acidic or basic characteristics of oils. TAN measures the acidity of oils, indicating the presence of acidic components that can lead to corrosion and degradation, while TBN measures the alkalinity, revealing the oil's ability to neutralize acidic substances. This tester typically involves titration, where a sample is treated with a reagent until a neutralization endpoint is reached. By determining TAN and TBN values, lubricant and oil manufacturers can assess the degradation and contamination levels, enabling informed decisions regarding oil change intervals and maintenance schedules.
mV measurement range | -2000.0 mV to 2000.0 mV |
mV measurement resolution | 0.1 mV |
mV measurement accuracy | 0.1 ± 0.03% mV |
pH measurement range | -20.00 to 20.00 pH |
Our auto ignition point tester is a specialized laboratory instrument designed to determine the autoignition temperature of flammable liquids and gases. The tester typically involves heating the sample in a controlled environment and monitoring for self-ignition. Commonly used in industries dealing with fuels, chemicals, and combustible materials, the Auto Ignition Point Tester provides essential information for ensuring safety and preventing unintended ignition in various processes and applications. Accurate knowledge of the autoignition point is crucial for designing and operating systems where flammable substances are present, such as in the production, storage, and transportation of fuels and industrial chemicals.
Temperature Range | 100°C to 800°C |
Temperature Accuracy | ± 1°C |
Injection Volume | 0.07 ml per injection |
Injection Interval | ≥ 15 minutes |
Our oil dielectric tester is a specialized instrument used in the electrical industry to evaluate the dielectric strength of insulating oils. This crucial parameter indicates the oil's ability to withstand electrical stress and prevent breakdown, ensuring the reliability of transformers and other high-voltage equipment. The tester typically operates by immersing electrodes in the oil sample and applying a voltage until electrical breakdown occurs. Regular testing with the Oil Dielectric Tester is essential for preventive maintenance, helping identify potential issues before they lead to equipment failure. This instrument is a valuable tool for power utilities, substations, and industrial facilities, contributing to the overall safety and performance of electrical systems by ensuring the insulating oils maintain the required dielectric properties over time.
Capacity | 1.5 kVA |
Voltage raise rate | 2.0 kV/s and 3.0 kV/s (optional) |
Output voltage | 0 kV ~ 80 kV |
Compliance | ASTM D1816 |
Labotronics Vapour Pressure Tester are designed to measure vapour pressure of liquids. They have a unique method to prevent sample cross-contamination. They are highly versatile, efficient, accurate, and portable. They have a maintenance-free chamber for high-intensity tests. Our Vapour Pressure Tester are primarily used for petrochemical analysis, environmental testing, quality control, pharmaceuticals, aerospace, and research.
Pressure Detection Range | 0 To 1000kPa |
Pressure Resolution (Sensitivity Threshold) | 0.01 kPa |
Temperature Range | 0 To 120°C |
Temperature Accuracy | ±0.1°C |
Our Dropping Point Tester is a specialized laboratory instrument designed to determine the dropping point of lubricating greases. This crucial parameter signifies the temperature at which the grease undergoes a transition from a semi-solid to a liquid state. Operating on the principle of heating a sample and observing the point at which a standard cone penetrates the softened grease, the tester ensures precise measurement of dropping points. Widely used in industries like automotive and machinery, this tester provides essential information about the temperature range within which a grease can effectively lubricate moving parts.
Temperature Control Range | 400℃ |
Temperature Control Point | 121℃,232℃,288℃,343℃ |
Temperature control accuracy | ± 3℃ |
Grease Cup Material | Chrome plated copper |
Temperature control range | |
Temperature control accuracy | |
Temperature control point | |
Glass bath capacity |
Temperature control range | |
Temperature control accuracy | |
Temperature control point | |
Glass bath capacity | 800 mL |
Categories