Our Laboratory analyzers are designed to examine, quantify, or assess the composition, properties, or characteristics of materials or substances. These instruments are used across various fields, including chemistry, biology, physics, and environmental science, to conduct analyses and gather data. Analyzers can encompass a broad range of devices, from gas chromatographs and mass spectrometers for chemical analysis to DNA sequencers and blood analyzers in the medical field. They serve vital roles in research, quality control, diagnostics, and manufacturing processes, providing precise measurements and insights to support scientific investigations and decision-making. Whether determining the purity of chemicals, identifying components in a sample, or assessing the concentration of specific substances, our analyzers are essential tools that enable a deeper understanding of materials and facilitate advancements in numerous industries and research disciplines.
Alloy analyzers Automatic biochemistry analyzer Automatic Immunoassay Hormone Analyzer Cetane Analyzer Chlorine Content Analyzer Differential thermal analyzers Electrolyte Analyzer Fat Analyzer Fixed Gas Analyzer Fixed Infrared analyzer Fully automatic chemistry analyzer Halogen Moisture Analyzer Hematology analyzer Infrared Oil Content Analyzer Metal Analyzer Multi Test Analyzer Multi-Gas Analyzers Multifunctional Process Analyzer Nitrogen Oxygen Analyzer Octane Analyzer Ore analyzers Precious metal analyzers Raw Fiber Analyzer RoHS analyzers Salt Content Analyzer Semi automatic chemistry analyzer Single Gas Analyzer Soil metal analyzers TOC AnalyzerTest Speed | Over 200 Tests/hour |
Interface | Connected to LIS by COM/USB |
Screen | LED Touch Screen |
Printer | Internal Thermal Printer |
Throughput | Without ISE: 600 T/hr With ISE: 780 T/hr |
Sample capacity | 104 position, Single sample tray |
Reagent capacity | 100 positions, R1:50, R2: 50, Non-stop 2 to 8°C refrigeration |
Sample volume | 1 to 100 µl, 0.1 µl/step |
Engine speed | 900 rpm ± 9 rpm |
Piston stroke | 114.3 mm |
Cylinder bore diameter | 82.55 mm |
Compression ratio range (adjustable) | 8:1 ~ 36:1 |
Oxygen bomb pressure | ≥ 20 MPa |
Ignition voltage | 12 V ~ 24 V |
Repeatability | 6 × 10-4 % |
Ambient temperature | 5 °C ~ 40 °C |
Temperature range | RT to 1150 ℃ |
Heating rate | 0.1 to 80℃/min |
Temperature resolution | 0.001 ℃ |
Temperature fluctuations | ± 0.001 ℃ |
Sample | Whole blood, serum, plasma, diluted urine |
Sample volume | 100 µL ~ 150 µL |
Throughput | up to 60 samples/h |
Measuring range | K+ - 0.50 mmol/L ~ 15.00 mmol/L Na+ - 30.0 mmol/L ~ 200.0 mmol/L Cl- - 30.0 mmol/L ~ 200.0 mmol/L Ca2+ - 0.10 mmol/L ~ 5.00 mmol/L pH - 4.0 ~ 9.50 (Unit) CO2 - 6.0 mmol/L ~ 50.0 mmol/L |
Capacity | 6 pcs/batch |
Measuring range | 0.1 % ~ 100 % |
Sample weight | 0.5 g ~ 15 g |
Temperature range | RT 5 °C ~ 300 °C |
Throughput | 60 tests / hr | ||||||||||||||||||||||||||||
Assay items | 22 parameters, 3 parts differential of WBC | ||||||||||||||||||||||||||||
Sample volume | 13 µL (Whole blood) 20 µL (Prediluted blood) |
||||||||||||||||||||||||||||
Parameter |
|
Range | 110 g |
Readability | 0.001 g |
Pan size | Φ 90 mm |
Communication mode | Press and continue |
Temperature range | RT ~ 120 °C |
Temperature control accuracy | RT ~ 50 °C ± 0.2 °C 50 °C ~ 100 °C ± 0.3 °C 100 °C ~ 120 °C ± 0.5 °C |
Oscillation frequency | 275 ± 3 period/min |
Oscillation amplitude | 35 mm |
Function | Chemistry + Coagulation |
Sample volume | 50 µL to 500 µL |
Wavelength | Chemistry: 340 nm,405 nm , 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Coagulation: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions , controlled at 37 °C ± 0.5 °C |
O2 concentration value | 21.0% ⁓ 99.9% |
N2 concentration value | 79.0 % ⁓ 99.9 % |
Gas flow | 150 ml/min ⁓ 300 ml/min |
Accuracy | ± 2 % FS |
Measurement range | 40 RON ~ 120 RON |
Speed range | 900 ± 9r / min ( Motor method ) 600 ± 6r / min ( Research method ) |
Pressure | ≥ 0.15 MPa |
Compression ratio range | 4:1 ~ 18:1 |
Basic measurement range | 0.001 to 100 mg/L |
Detection limit | < 0.12mg/L (extraction agent, Direct measurement) < 0.0012mg/L (Oil concentration in water samples) |
Measurable concentration | ≤ 640000mg/L (Dilution measurement): ≤ 100% oil |
Testing accuracy | ± 0.5 (<10 mg/L) ± 2% (10 to 80 mg/L) |
Measuring range | 0.001 to 1.2 mg/L |
Accuracy | ± 3% |
Resolution | 0.001 mg/L |
Repeatability | ≤ 3% |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Pb, Hg, Cd, Cr, Br and As |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Capacity | 6 samples |
Reproducibility error | Raw fiber level < 10%: Absolute value error ≤ 0.4% Raw fiber level > 10%: Absolute value error ≤ 4% |
Measuring time | About 100 min (including acid 40 min, alkali 40 min, filter and wash 20 min) |
Water supply | Water pressure > 1.5 Mpa |
Halide concentration range | 0.002 % ~ 0.02 % |
Insulating resistance | ≥ 2 MΩ |
Extractor | Potentiometric standard as per ASTM D6470 |
Heating power of extractor | 300 W |
Measuring volumes | 450 µL to 800 µL |
Incubator | 20 incubating positions |
Wavelength | 340 nm /405 nm /492 nm /510 nm /546 nm /578 nm /620 nm, 2 more filters available on request |
Wavelength accuracy | ± 2 nm |
Measuring range | 1 mg/L ~ 10000 mg/L |
Testing parameters | TC TIC TOC NPOC |
Digestion mode | Wet chemical oxidation by UV |
Detector | NDIR |
Throughput | Without ISE: 800 T/hr With ISE: 980 T/hr |
Sample capacity | 104×2 position, Dual sample tray |
Reagent capacity | 100 positions, R1:50, R2: 50, Non-stop 2 to 8°C refrigeration |
Sample volume | 1 to 100 µl, 0.1 µl/step |
Capacity | 6 pcs/batch |
Measuring range | 0.5 % ~ 60 % |
Temperature range | RT 0 °C ~ 100 °C |
Heating time | Within 10 min |
Range | 110 g |
Readability | 0.002 g |
Pan size | Φ 90 mm |
Communication mode | Press and continue |
Function | Chemistry + specific protein |
Sample volume | 100 µL to 500 µL |
Wavelength | Chemistry: 340 nm,405 nm , 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Specific protein: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions , controlled at 37 °C ± 0.5 °C |
O2 concentration value | 21.00% ⁓ 99.99% |
N2 concentration value | 79.00 % ⁓ 99.99 % |
Gas flow | 150 ml/min ⁓ 300 ml/min |
Accuracy | ± 2 % FS |
Measuring range | 0.001 to 1.6 mg/L |
Accuracy | ± 3% |
Resolution | 0.001 mg/L |
Repeatability | ≤ 3% |
Measuring volumes | 451 µL to 800 µL |
Incubator | None |
Wavelength | 340 nm /405 nm /492 nm /510 nm /546 nm /578 nm /620 nm, 2 more filters available on request |
Wavelength accuracy | ± 2 nm |
Measuring range | 0 mg/L ~ 30000 mg/L |
Testing parameters | TC TIC TOC |
Digestion mode | High temperature combustion |
Detector | NDIR |
Range | 110 g |
Readability | 0.003 g |
Pan size | Φ 90 mm |
Communication mode | Press and continue |
Function | Chemistry + Coagulation + Specific protein |
Sample volume | 50 µL to 500 µL |
Wavelength | Chemistry: 340 nm,405 nm , 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Coagulation: 450 nm, 670 nm Specific protein: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions , controlled at 37 °C ± 0.5 °C |
O2 concentration value | 21.000% ⁓ 99.999% |
N2 concentration value | 79.000 % ⁓ 99.999 % |
Gas flow | 150 ml/min ⁓ 300 ml/min |
Accuracy | ± 2 % FS |
Range | 110 g |
Readability | 0.001 g |
Pan size | Φ 80 mm |
Communication mode | Press and continue |
Range | 110 g |
Readability | 0.001 g |
Pan size | Φ 100 mm |
Communication mode | Cable |
Range | 110 g |
Readability | 0.001 g |
Pan size | Φ 100 mm |
Communication mode | Wireless |
Range | 210 g |
Readability | 0.001 g |
Pan size | Φ 100 mm |
Communication mode | Cable |
Range | 210 g |
Readability | 0.001 g |
Pan size | Φ 100 mm |
Communication mode | Wireless |
Assay | 80 assay |
Throughput 1 Reagent | 400 tests / h |
Throughput 2 Reagent | 400 tests / h |
Throughput with ISE | + 120 tests/h |
Throughput | 60 tests / hr. | ||||||||||||||||||||||||||||
Parameters | 28 parameters + 3 histograms + 1 scattergram | ||||||||||||||||||||||||||||
Sample type | Whole blood: 50 µL or Capillary blood: 20 µL | ||||||||||||||||||||||||||||
Parameter |
|
Assay | 40 assay |
Throughput 1 Reagent | 300 tests / h (max) |
Throughput 2 Reagent | 240 tests / h |
Throughput with ISE | + 120 tests/h |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | CO, O2, Cl2, SO2, O3, CO2, CH4, H2S, NH3, NO, NO2, H2, LEL, LPG, PID, EXP, CH4 (IR), C3H8 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Assay | 40 assay |
Throughput 1 Reagent | 240 tests / h (max) |
Throughput 2 Reagent | 150 tests / h |
Throughput with ISE | + 120 tests/h |
Assay | 36 assay |
Throughput 1 Reagent | 200 tests / h (max) |
Throughput 2 Reagent | 150 tests / h (max) |
Throughput with ISE | + 100 tests/h |
Sensor | High sensitivity sensor |
Sampling method | Pump aspiration |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Pump aspiration |
Detection range | H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Fe, Co, Ni, Cu, Zn, Se, Ru, Rh, Pd, Ag, Cd, In, Ir, Pt, Au and Pb |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Gas detection | THC, CO2, CO, NOX, SO2 |
Sensors | Electrochemistry: CO,NOX,SO2 Infrared Ray: CO2 PID: THC |
Measuring range | THC: 0 to 10000 ppm CO2: 0 to 20% VOL CO: 0 to 10% VOL NOX: 0 to 5000 ppm SO2: 0 to 5000ppm |
Resolution | THC,NOX,SO2: 1 ppm CO2,CO: 0.01% VOL |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | O2, CH4, CO, H2S, SO2, Cl2, NH3, NO2, NO, H2, HCl, HCN, CH4, PID (VOCs), CO2, C3H8 and O3 |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | Non-dispersive infrared sensor |
Sampling method | Diffusion |
Detection range | CO, O2, Cl2, SO2, O3, CO2, CH4, H2S, NH3, NO, NO2, H2, LEL, LPG, PID, EXP, CH4 (IR), C3H8 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Re, Pd, Au, Hg, Pb, Bi, Cs, Ba, Th and U |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, W, Au, Hg, Pb, Bi, Ba, Th, U, Sc, Cs, Te, Pd, Hf, Ta, Re, Ge Tl and I |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Cl ,K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Rb, Sr, Y, Zr, Nb, Mo, Ag, Cd, Sn, Sb, Hf, Ta, W, Au, Hg, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 ° C) |
Detector | BOOST Si-pin detector |
Detection range ( ppm ) | Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |
Detector | SDD detector |
Detection range ( ppm ) | Mg, Al, Si, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Zr, Nb, Mo, Rh, Pd, Ag, Cd, Sn, Sb, Hf, Ta, W, Re, Pb and Bi |
Excitation source ( standard ) | 50 kV / 200 µA Ag target |
Operating temperature | ( -20 °C to 50 °C ) |