Liquid Chromatography LB-11LC is a high-performance table top unit for isolation of the individual components of a mixture. It features highly integrated separation functions for precise results through UV - Visible detectors. It’s a fully automated system with isocratic and gradient pumping system.
Buy Now Download CatalogSpecifications
Pump System | Isocratic |
Pump Flow Rate | 0.001 to 9.999 mL/min |
Pump Flow Rate Accuracy | ≤ ± 0.5% (1 mL/min, water, room temperature) |
Pump Flow Rate Precision | RSD ≤ 0.08% (1 mL/min, water, room temperature) |
Pressure Range | ≤ 42 MPa |
Detector Lamp | Deuterium lamp |
Wavelength Range | 191 nm to 700 nm |
Baseline Noise | ≤ 8 × 10⁻⁶ AU |
Baseline Drift | ≤ 1 × 10⁻⁴ AU/h |
Detection Limit | 4 × 10⁻⁹ g/mL (Naphthalene/methyl alcohol solvent) |
Wavelength Accuracy | ±1 nm |
Pump Dimensions | 470 × 380 × 300 mm |
Detector Dimensions | 470 × 380 × 400 mm |
Pump Net Weight | 8 kg |
Detector Net Weight | 8 kg |
Pump Gross Weight | 10 kg |
Detector Gross Weight | 10 kg |
Gross Weight | 10 kgs |
Features
Applications
Used in clinical diagnosis of diseases and disorders, scientific research and development, pharmaceutical labs for drug analysis, cosmetic industries, botanical laboratories, food and beverage industries for quality control, standard controls, etc.
What our customers say
Add a review
Pump System | Gradient |
Pump Flow Rate | 0.001 to 9.999 mL/min |
Pump Flow Rate Accuracy | ≤ ± 0.5% (1 mL/min, water, room temperature) |
Pump Flow Rate Precision | RSD ≤ 0.08% (1 mL/min, water, room temperature) |
Laboratory gas chromatography is a powerful analytical technique used for the separation and analysis of volatile compounds within a controlled laboratory environment. It operates based on the principles of gas-liquid partitioning, where a sample is injected into a chromatographic column and then vaporized and carried by an inert gas through the column. As the sample travels through the column, different components separate based on their affinity for the stationary phase, with each component eluting at a specific time, creating a chromatogram. Our laboratory GC is widely employed in various scientific disciplines, including chemistry, biochemistry, environmental science, and forensic analysis. It is used for tasks such as identifying and quantifying compounds in complex mixtures, analyzing volatile organic compounds, and ensuring product quality control. The technique offers high sensitivity and precision, making it an essential tool for researchers and scientists to understand and characterize chemical compositions.
Sample injector temperature range | |
Power supply | AC 110 V / 220 V ± 10 % ; 50 Hz / 60 Hz |
Dimensions ( W x D x H ) | 800 x 570 x 650 mm |
Gross weight | 75 kgs |
Sample injector temperature range | RT +7 °C ~ 420 °C |
Power supply | AC 220 V ± 10 % ; 50 Hz / 60 Hz |
Dimensions ( W x D x H ) | 1020 x 660 x 740 mm |
Gross weight | 82 kgs |
Laboratory ion chromatography is a versatile analytical technique used for the precise separation and quantification of ions in controlled laboratory settings. It involves a sample's injection into a chromatographic system, where ions are separated within a column based on their affinity for a stationary phase. Our ion chromatography is particularly valuable for analyzing inorganic ions, both anions and cations, and it finds extensive applications in environmental monitoring, water quality assessment, pharmaceutical research, and food and beverage analysis. Offering high sensitivity and selectivity, IC empowers scientists to accurately determine the composition and concentration of ions in diverse samples, playing a crucial role in quality control, scientific research, and understanding ionic content in various materials and solutions within the laboratory.
Dimensions (L x W x H) | 500 x 570 x 510 mm |
Weight | 40 kgs |
Whole plastic pipeline | Made of PEEK material |
Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically. |
Dimensions (L x W x H) | 325 x 400 x 500 mm |
Weight | 21 kgs |
Whole plastic pipeline | Made of PEEK material |
Six way valve | PEEK material FLOM series of six way valve, pressure 5000 psi, a signal automatic collecting and flow function |
Dimensions (L x W x H) | 350 x 470 x 650 mm |
Weight | 34 kgs |
Whole plastic pipeline | Made of PEEK material |
Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically |
Dimensions (L x W x H) | 350 x 470 x 510 mm |
Weight | 26 kgs |
Whole plastic pipeline | Made of PEEK material |
Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically. |
Our Solid Phase Extractors are essential for efficient sample preparation, enabling laboratories to isolate and purify target compounds from complex matrices. These units are equipped with advanced materials that minimize cross-contamination and optimize analyte purity. They also support eco-friendly practices by reducing solvent consumption and waste generation. The user-friendly interface simplifies operation, minimizing the chances of errors during sample preparation. Our SPE systems are designed for versatile applications across pharmaceuticals, environmental testing, food safety, and clinical diagnostics.
Capacity | 24 Holes |
Workplace dimensions | 240 × 70 × 138 mm |
Pressure Display | Pressure Gauge |
Vacuum Degree | 0.098 MPa |
Labotronics Thin-Layer Chromatography systems facilitate effective compound separation ensuring high reproducibility for various experiments. These TLC systems are designed to be compatible with a wide range of solvents, allowing for versatile applications in laboratory settings. They offer customizable adsorbent layer thickness, improving separation efficiency and resolution for diverse analytical needs. Our TLC systems are designed for both small-scale studies and large-scale industrial applications, offering essential support for researchers and quality control professionals.
Camera | 20 million pixels |
Pixel Density | 16-bit (65536 grayscale) |
Focus Method | Autofocus |
Exposure Timer Range | 0 to 2000 ms |