Melt Flow Rate Tester LB-11MFR

Melt Flow Rate Tester LB-11MFR

Melt flow rate tester LB-11MFR is a microprocessor-controlled system for rate extrusion determination. Maintenance of specific temperature and pressure delivers precise result delivery. Manual and automatic test methods adaptability provide ease of accessibility. It is designed to conform to ASTM 1238 international testing standard.

Buy Now Download Catalog

Specifications

Temperature range 80 °C ~ 400 °C
Temperature accuracy ± 0.5 °C
Temperature fluctuation ± 0.2 °C
Temperature display resolution 0.1 °C
Time display resolution 0.1 sec
Cylinder diameter 2.095 mm ± 0.005 mm
Length of discharge port 8 mm ± 0.025 mm
Loading cartridge diameter 9.55 mm ± 0.025 mm
Weight accuracy ± 0.5 %
Dimensions 250 × 350 × 510 kgs
Weight 9 kgs

Features

  • Digital LCD screen for visual monitoring of data
  • Quick isothermal state restoration
  • Easy calibration and correction of test parameters
  • Printing adaptation provides long-lasting data collection

Applications

Used to measure the MFR value of various polymers such as polycarbonate, polysulfonate, nylon, resin, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Kamran Asad logo

3 months ago

Jason Ford logo

9 months ago

MIRZA AFZAL ALI logo

2 years ago

Abid Hasan logo

1 year ago

Add a review

Melt Flow Rate Tester

Melt Flow Rate Tester : Melt Flow Rate Tester LB-10MFR
Temperature Range 10°C to 40°C
Relative Humidity 30% to 80%
Temperature Control Range RT to 400℃
Temperature Deviation ≤ ± 0.2°C

Labotronics BOD Meter with high-precision sensors provides accurate and reliable readings, crucial for water quality assessment. Its user-friendly operation simplifies the testing process, making it accessible for all users. Our meter offers automatic data logging, enabling easy analysis and reporting. Provides accurate data for effective water management with enhanced decision-making capabilities. It saves costs by minimizing repeat testing and waste, ensuring both economic and environmental sustainability.

BOD Meter LB-11BOD

Measuring principle Differential pressure method
Measuring range 0 to 2000 mg/L
Culture bottle capacity 580 ml
Sample capacity 6
BOD Meter LB-10BOD
Measuring principle Mercury free pressure differential method
Measuring range 0 to 4000 mg/L
Resolution 0.01 mg/L
Accuracy ±8%

Our Gas Flow Meters accurately measure gas flow rates, providing reliable performance for various laboratory and industrial applications. They feature advanced flow meter technology for measuring mixed gas compositions, providing accurate analysis in complex settings. They include multiple output options, such as analog and digital signals, ensuring compatibility with various data acquisition systems. They provide flexible installation options, including wall-mounted and portable designs, to suit different operational needs. Our gas flow meters incorporate automatic zeroing and calibration options for consistent and reliable measurements.

Medium All gases (except acetylene gas)
Flow Rate 150 L/min
Velocity 0.1Nm/s to 100Nm/s (standard working condition 20 °C101.33Kpa)
Accuracy 0.01
Medium Gas
Flow Rate 0 to 60 l/min
Accuracy ±1% FS
Pressure Range 0.05 Mpa to 0.3 MPa

Our laser distance tester is a handheld instrument designed for accurately measuring distances using laser technology. It emits a laser beam towards a target surface, and the time it takes for the laser to reflect back to the device is calculated to determine the distance. These testers are widely used in construction, surveying, and various industries for quick and precise measurements. With features like high accuracy, ease of use, and the ability to measure both short and long distances, Laser Distance Testers offer efficiency and reliability in applications such as building layout, interior design, and land surveying. They have become indispensable tools for professionals requiring fast and accurate distance measurements in diverse settings.

Range 0.05 m ~ 60 m
Distance measurement precision ± 1.5 mm
Measurement time Single measurement: 0.3 sec/time Continuous measurement: 7 times/sec
Measurement unit options mm/in/ft
Range 0.05 m ~ 40 m
Distance measurement precision ± 1.5 mm
Measurement time Single measurement: 0.3 sec/time Continuous measurement: 7 times/sec
Measurement unit options mm/in/ft
Range 0.05 m ~ 80 m
Distance measurement precision ± 1.5 mm
Measurement time Single measurement: 0.3 sec/time Continuous measurement: 7 times/sec
Measurement unit options mm/in/ft
Range 0.05 m ~ 100 m
Distance measurement precision ± 1.5 mm
Measurement time Single measurement: 0.3 sec/time Continuous measurement: 7 times/sec
Measurement unit options mm/in/ft

Our multifunction environment meter is versatile devices designed to measure and monitor various environmental parameters in a single, compact instrument. Typically equipped with sensors for temperature, humidity, air velocity, and light, this meter provides comprehensive data for assessing and optimizing indoor or outdoor conditions. The user-friendly interface and often digital display make it easy to obtain real-time readings, allowing professionals such as HVAC technicians, researchers, and facility managers to efficiently manage and control environmental variables. With its multifunctionality, the device streamlines data collection and analysis, promoting accuracy in applications ranging from climate control to environmental research, enhancing overall efficiency in maintaining optimal conditions across diverse settings.

Temperature range -40 °C ~ 70 °C -40 °F ~ 158 °F
Temperature resolution 0.1 °C/0.1 °F
Temperature accuracy ± 2.0 °C, ± 3.6 °F
Temperature measurement units °C , °F

Labotronics Dilatometers offer precise measurements of thermal expansion, for accurate analysis of material behavior. They function effectively across a wide temperature range, accommodating diverse material testing requirements. They incorporate advanced technology ensuring high sensitivity and reliability in measurement results. They include automatic data recording, facilitating efficient monitoring of experimental conditions. They offer various testing methods, including manual pressing and dynamic hammering, for versatile applications. Our dilatometers feature an integrated LCD color screen for clear visualization of data and settings, improving the overall user experience.

Flat Blade Test Probe Length: 230 to 240 mm Width: 95mm Thickness: 15mm
Steel Membrane Size 60 mm
Air Pressure Rating 6 Mpa
Maximum Depth Tested 0 To 50 m
WhatsApp
×

Get Quotation

Follow Us

Copyright © Labotronics Scientific 2025