Salt Content Analyzer LB-10SAA

Salt Content Analyzer LB-10SAA

Salt content analyzer LB-10SAA is a microprocessor controlled unit for halide concentration determination. The potentiometric method of estimation delivers reliable results. It is designed conforming to ASTM D6470 international testing standards.

Buy Now Download Catalog

Specifications

Halide concentration range 0.002 % ~ 0.02 %
Insulating resistance ≥ 2 MΩ
Extractor Potentiometric standard as per ASTM D6470
Heating power of extractor 300 W
Power consumption 600 W
Power supply AC 220 V ± 10 V; 50 Hz
Dimensions (Accessories) 750 × 550 × 460 mm
Dimensions (Main unit) 800 × 370 × 640 mm
Weight (Accessories) 18 kgs
Weight (Main Unit) 24 kgs

Features

  • Digital LCD screen for visual monitoring of resulting data
  • Automatic salt concentration calculation
  • Turbine oil and marine fuel oil pollution estimation

Applications

Used to determine the amount of salt and halide concentration in crude oil, fuels, lubricants, reduce oil, cracking residual oil, turbine oil, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Oluwatobi ADEDOTUN logo

1 year ago

Ahmed Salah logo

4 days ago

Javad Abudov logo

1 year ago

Radwa Adel logo

1 year ago

Adi Purwanto logo

1 year ago

Engy Samy logo

1 year ago

BASIM JAMEL logo

1 year ago

Karl Heinz logo

1 year ago

Nasim Akhtar logo

3 weeks ago

Hakkeem N. Abdullah logo

8 months ago

SYUKUR HIDAYAT logo

2 years ago

Gokul R.S logo

2 years ago

Kadar Basha logo

3 years ago

Add a review

An octane analyzer is a specialized instrument used to determine the octane rating of gasoline or fuel samples, a critical parameter that assesses the fuel's resistance to knocking or pre-ignition in internal combustion engines. These analyzers employ various techniques, including research octane number and motor octane number testing, to measure a fuel's anti-knock properties. They find extensive application in the petroleum industry, automotive research, and quality control, ensuring that gasoline meets specified octane ratings and performs optimally in engines. Our octane analyzers provide accurate data to refine fuel formulations, develop higher-performing gasoline, and comply with regulatory standards, thereby contributing to engine efficiency, reduced emissions, and enhanced overall automotive performance

Measurement range 40 RON ~ 120 RON
Speed range 900 ± 9r / min ( Motor method ) 600 ± 6r / min ( Research method )
Pressure ≥ 0.15 MPa
Compression ratio range 4:1 ~ 18:1

Our Chlorine Content Analyzer is a specialized instrument used to quantitatively determine the chlorine content in various substances, particularly in chemical processes and industrial applications. It employs techniques such as titration, spectroscopy, or combustion analysis to measure the concentration of chlorine in samples. These analyzers are essential for quality control, process optimization, and compliance with environmental regulations in industries like petrochemicals, plastics, and water treatment. By providing accurate data on chlorine levels, these analyzers help ensure product quality, safety, and adherence to industry standards. Chlorine Content Analyzers play a crucial role in maintaining the integrity of processes and products across a range of industrial sectors, where precise chlorine content measurements are paramount.

Oxygen bomb pressure ≥ 20 MPa
Ignition voltage 12 V ~ 24 V
Repeatability 6 × 10-4 %
Ambient temperature 5 °C ~ 40 °C

Nitrogen Analyzer is a scientific instrument designed to quantify the nitrogen content in various substances. Employing techniques such as combustion, chemiluminescence, or infrared spectroscopy, it accurately measures nitrogen levels in samples like soil, plant material, or organic compounds. Widely used in agriculture, environmental science, and industrial settings, the analyzer aids in optimizing fertilizer application, assessing soil health, and monitoring pollution. Its precision and speed make it a crucial tool for researchers and professionals, facilitating data-driven decisions and promoting efficient resource management.

Sample Types Solid, Gas, Liquid
Working Principle Chemiluminescence method (N)
Sample Injection Quantity Solid: 1to 20 mg Liquid: 5 to 20 μL Gas: 1to 5 mL
Measuring Range 0.05 to 20000 ppm (mg/L) (High concentration diluted)
Measuring range 79.0% to 99.9%
Sample Gas Flow 150 to 300 ml/min
Visible Display Window 90 × 25 mm
Accuracy ±2% F. S

Our multifunctional process analyzer is a highly versatile and integrated analytical instrument used in industrial and manufacturing settings to monitor and control a wide array of parameters throughout various production processes. These analyzers encompass a range of measurement techniques, including spectroscopy, chromatography, and electrochemistry, to simultaneously analyze multiple aspects of the production process, such as chemical composition, temperature, pressure, and flow rates. Multifunctional process analyzers offer real-time data, aiding in quality control, process optimization, and regulatory compliance. They are essential in industries like petrochemical, pharmaceutical, and food manufacturing, helping to ensure product quality, safety, and adherence to industry standards.

Temperature range RT ~ 120 °C
Temperature control accuracy RT ~ 50 °C ± 0.2 °C 50 °C ~ 100 °C ± 0.3 °C 100 °C ~ 120 °C ± 0.5 °C
Oscillation frequency 275 ± 3 period/min
Oscillation amplitude 35 mm

Labotronics Infrared Oil Content Analyzer is a sophisticated instrument designed for accurate measurement of oil content in various samples. Utilizing infrared technology, this analyzer determines the concentration of oil by analyzing the absorption of specific wavelengths of infrared light. Its precision and reliability make it an essential tool in industries such as food, cosmetics, and petrochemicals, where precise measurement of oil content is crucial for quality control. The user-friendly interface and rapid analysis capabilities streamline the testing process, enabling efficient and reliable results.

Measurement Range 0.001 to 2000 mg/L (4 cm cuvette)
Detection Limit ˂ 0.12 mg/L (direct measurement) ˂ 0.0012 mg/L (oil in water)
Measurable Concentration ≤ 640000 mg/L (dilution)
Accuracy ± 0.5% (