Vertical Electrophoresis Unit LB-20VEU is vertical unit with leak proof assembly for producing well defined bands. Large volume buffer ensures cooling effects and stable pH value during experimental process. Seals surrounding glass plates on both sides ensures fast set up time and leak proof operation.
Buy Now Download CatalogSpecifications
Gel area (W x L) | 82 x 88 mm |
Glass plate area (W x L) | 100 x 100 mm |
Buffer volume | 750 mL |
No of samples | 11 to 30 |
Gel making mode | Gel casting |
Gel thickness | 0.75 mm, 1.0 mm, 1.5 mm |
Amount of gel | 1 ~ 2 piece |
Dimensions (L x W x H) | 150 x 120 x 115 mm |
Weight | 1.5 kgs |
Features
Applications
Used in molecular biology, life science, research and diagnostic lab, education institutes for protein analysis, purification of nucleic acid, sample purification, preparation and analysis, etc.
Standard Accessories
Sr No | Accessory name | Quantity |
---|---|---|
1 | Body tank with electrode | 1 |
2 | Gel casting base | 1 |
3 | Notched glass plate | 4 |
4 | 0.75 mm bonded glass spacer | 2 |
5 | 1.0 mm bonded glass spacer | 2 |
6 | 1.5 mm bonded glass spacer | 2 |
7 | 0.75 mm thickness 11 wells comb | 2 |
8 | 1.0 mm thickness 15 wells comb | 2 |
9 | 1.5 mm thickness 15 wells comb | 2 |
10 | 0.75 mm thickness 15 wells comb | 2 |
11 | 1.0 mm thickness 15 wells comb | 2 |
12 | 1.5 mm thickness 15 wells comb | 2 |
13 | Gel Shovel | 1 |
14 | Clamp version | 2 |
15 | Dummy plate | 1 |
16 | Electrical cables | 1 |
What our customers say
Eng.Enas Jayyousi
2 years ago
Yibeltal yihunie
1 year ago
Mian Sadiq Shah
2 years ago
S. Kavidhas
2 years ago
Arshad Mahmood
2 years ago
Eng Faisal Khan
3 years ago
Abel Bereket
1 year ago
Syed Zaheer
3 years ago
Mae .
1 year ago
Add a review
Gel area (W x L) | 81 x 73 mm |
Glass plate area (W x L) | 101 x 82 mm |
Buffer volume | 1200 mL |
No of samples | 11 to 60 |
Glass tray (W x L) | 216 x 220 mm |
Gel tray (W x L ) | 186 x 205 mm |
Comb thickness | 1 mm |
Comb throughput | 25, 40, 52 samples |
Gel area (W x L) | 82 x 88 mm |
Glass plate area (W x L) | 100 x 100 mm |
Buffer volume | 1000 mL |
No of samples | 11 to 60 |
Gel area (W x L) | 186 x 205 mm |
Glass plate area (W x L) | 216 x 220 mm |
Buffer volume | 3500 mL |
No of samples | 25, 40, 52 samples |
Gel area (W x L) | 186 x 95 mm |
Glass plate area (W x L) | 216 x 110 mm |
Buffer volume | 1800 mL |
No of samples | 25 , 40, 52 samples |
Gel area (W x L) | 186 x 205 mm |
Glass plate area (W x L) | 216 x 220 mm |
Buffer volume | 3500 mL |
No of samples | 25,40, 52 samples |
Gel area (W x L) | 186 x 95 mm |
Glass plate area (W x L) | 216 x 110 mm |
Buffer volume | 1800 mL |
No of samples | 25, 40, 52 samples |
Glass tray (W x L) | 100 x 100 mm |
Gel tray (W x L ) | 82 x 88 mm |
Comb thickness | 0.75 mm ,1.0 mm and 1.5 mm |
Comb throughput | 11,15 samples |
Our Electrophoresis Power Supplies provides precise voltage and current control for various electrophoretic applications. The eco-friendly designs incorporate energy-efficient technologies to reduce carbon footprints and comply with stringent environmental regulations. They are equipped with digital displays for real-time monitoring of parameters. Their compact, lightweight design allows for easy integration into any lab environment. Labotronics electrophoresis power supplies are designed for various laboratory applications, including nucleic acid and protein electrophoresis.
Output Voltage | 6 to 600 V |
Output Current | 4 to 400 mA |
Output Power | 240 W |
Output Terminal | 4 pairs in parallel |
Our denaturing gradient gel electrophoresis (DGGE) Unit is a specialized laboratory apparatus employed in molecular biology and genomics research for the separation and analysis of DNA fragments based on their sequence variations. It utilizes a polyacrylamide gel with a linear or gradient denaturant, typically formamide and urea, to induce DNA denaturation. As DNA fragments migrate through the gel under the influence of an electric field, they experience different levels of denaturation, leading to distinct migration patterns. DGGE Units are integral for applications such as genetic fingerprinting, mutation analysis, and ecological studies, providing valuable insights into DNA sequence variations and their functional implications.
Glass plate area (W x L) | 200 x 200 mm |
Gel area (W x L) | 162 x 175 mm |
Buffer volume | 10 L |
No of samples | 1 to 70 |
Our 2D Gel Electrophoresis Unit is a specialized laboratory apparatus used for the separation and analysis of complex mixtures of proteins or nucleic acids. It employs a two-dimensional separation technique to provide higher resolution and detailed information about the components within a sample. This technique is widely used in molecular biology, proteomics, and genomics research to study protein expression, post-translational modifications, and biomarker discovery, offering valuable insights into various biological processes and diseases. Our 2D Gel Electrophoresis Units are essential tools for scientists and researchers aiming to unravel the complexities of biomolecules.
Glass Tube Length | 120 mm (1D) |
Gel Size (W × L) | 143 × 139 mm (2D) |
Number of Samples | 17 to 58 |
Buffer Volume | 2500 ml |
Labotronics cellulose acetate membrane electrophoresis unit is a laboratory apparatus used for the separation of proteins and other biomolecules. It employs cellulose acetate membrane strips, which function as the supporting matrix for electrophoresis. Our acetate membrane electrophoresis is a versatile technique used in biochemical research, clinical diagnostics, and quality control applications in various industries. It offers a cost-effective and efficient means of separating and analyzing biomolecules, making it a valuable tool for researchers and scientists
Bridge dimension (W x L) | (70 x 250) mm x 2 (90 x 250) mm x 2 |
Cell membrane dimension (W x L) | 70 x 90 cm |
Buffer capacity | 1000 mL |
Thickness of cellulose acetate membrane | < 1 mm |
Bridge dimension (W x L) | 66 x 250 mm 82 x 250 mm |
Cell membrane dimension (W x L) | 70 x 90 cm |
Buffer capacity | 560 mL |
Thickness of cellulose acetate membrane | < 1 mm |
Our horizontal electrophoresis unit is a laboratory apparatus used for separating macromolecules, such as DNA, RNA, or proteins, based on their size and charge during electrophoresis. It consists of a horizontal gel chamber with two electrodes on opposite ends and a casting tray where the gel is formed. Samples are loaded into wells within the gel, and an electric field is applied horizontally, causing the molecules to migrate through the gel matrix. This unit is versatile and widely used in molecular biology, genomics, and protein analysis for tasks such as DNA fragment separation, protein profiling, and nucleic acid purification.
Gel Size (L × W) | 60 × 60 mm 60 × 120 mm 120 × 60 mm 120 × 120 mm |
Number of Samples | 2 to 100 |
Buffer Volume | 650 ml |
Comb | 2 + 3 wells 6 + 3 wells 8 + 18 wells 11 + 25 wells |
Gel trays (W x L) | 48 x 75 mm |
Buffer volume | 150 ml |
Comb thickness | 1 mm and 1.5 mm |
Comb throughput | 3, 5, 9 samples |
Gel trays (W x L) | 120 x 120 mm, 120 x 60 mm, 60 x 120 mm, 60 x 60 mm |
Buffer volume | 550 mL |
No of samples | 1 to 100 |
Rows of comb | 1 ~ 4 |
Gel trays (W x L) | 78 x 100 mm |
Buffer volume | 400 mL |
No of samples | 10 to 30 |
Rows of comb | 1 ~ 2 |