Class I Biosafety Cabinet LB-10BSC Personnel And Environmental Containment System


Class I Biosafety Cabinet LB-10BSC is a laboratory containment system designed to protect personnel and the environment during handling of low- to moderate-risk biological materials. It uses inward airflow and HEPA-filtered exhaust to contain airborne contaminants and is suitable for microbiology, pharmaceutical, and research laboratory applications.

Product Snapshot

Attribute

Details

Product Name

Class I Biological Safety Cabinet

Model Number

LB-10BSC

Product Type

Personnel and Environmental Containment System

Used For

Handling low- to moderate-risk biological agents while ensuring operator and environmental safety

Industries

Microbiology, Biotechnology, Pharmaceutical Research, Academic and Diagnostic Laboratories

Alternative Equipment

Class II Biological Safety Cabinet, Laminar Flow Cabinet, Fume Hood

Warranty

1 Year Standard Warranty

Support

Installation guidance, operational training, and technical documentation provided


What Is This Product Used For?

Class I Biosafety Cabinet LB-10BSC is used for laboratory procedures that generate aerosols or involve potentially infectious materials. It maintains operator and environmental protection through inward airflow and HEPA-filtered exhaust systems.

Typical applications include:

  • Biological sample preparation

  • Pipetting and blending operations

  • Cell disruption procedures

  • Microbiological testing

  • Aerosol-generating laboratory processes

  • Biosafety containment procedures

It is suitable for laboratory workflows where biological containment is required without product sterility protection.


Industries That Use This Product

This cabinet is commonly installed in laboratory environments prioritizing biosafety and containment operation, including:

  • Microbiology and molecular biology laboratories

  • Pharmaceutical and biotechnology research facilities

  • Public health and veterinary laboratories

  • Academic research and teaching laboratories

  • Clinical and diagnostic testing centers

Labotronics LB-10BSC is suitable for BSL-1 and BSL-2 laboratory environments.


How Does Class I Biosafety Cabinet LB-10BSC Work?

Labotronics LB-10BSC operates using controlled inward airflow and HEPA filtration systems to minimize aerosol exposure during laboratory procedures.

Inward Airflow and Containment
Ambient air is drawn through the front opening at controlled velocity to create a containment barrier that minimizes aerosol escape.

HEPA Filtration Process
Contaminated air passes through a HEPA filter with ≥99.97% efficiency for 0.3 µm particles before exhaust discharge into the environment.

Negative Pressure Chamber
The internal workspace operates under negative pressure conditions to maintain biological containment during operation.

Exhaust System
Filtered air is discharged through a ducted or recirculating exhaust configuration depending on laboratory installation requirements.

Core Functional Capabilities

Key operational capabilities of the Labotronics LB-10BSC include:

  • Inward airflow containment system

  • HEPA-filtered exhaust for environmental protection

  • Negative pressure chamber operation

  • Stainless-steel internal workspace

  • Adjustable front sash configuration

  • Integrated UV sterilization lamp

  • Microprocessor airflow monitoring system

  • LED illumination for workspace visibility

  • Visual and audible alarm indication

These capabilities support biosafety operation in controlled laboratory environments.


Technical Specifications

Parameter

Specification

Airflow Type

Inward airflow with HEPA-filtered exhaust

Air Velocity

0.3 – 0.5 m/s

Filtration Efficiency

≥ 99.97% for 0.3 µm particles

Noise Level

≤ 65 dB

Lighting

≥ 800 Lux (LED)

Material of Construction

Stainless steel interior, powder-coated steel exterior

Control System

Microprocessor with digital display and alarm indicators

UV Lamp

30 W

Power Supply

220 V AC, 50/60 Hz

Dimensions (W × D × H)

1200 × 700 × 1950 mm

Weight

Approx. 100 kg


How to Choose This Class I Biological Safety Cabinet

Labotronics LB-10BSC is suitable when:

  • Low- to moderate-risk biological materials are handled

  • Operator and environmental protection are required

  • Aerosol-generating procedures are conducted

  • Non-sterile biological workflows are performed

  • Ducted or ductless installation flexibility is preferred

Laboratories operating under BSL-1 and BSL-2 conditions commonly select this model for routine biosafety containment procedures.


Alternative Equipment for This Product

Depending on laboratory operation and containment requirements, alternatives may include:

  • Class II Biosafety Cabinets – for personnel, product, and environmental protection

  • Laminar Flow Cabinets – for sterile sample handling without biological containment

  • Fume Hoods – for chemical vapor extraction

  • PCR Workstations – for contamination-controlled molecular workflows

Each system serves specific laboratory containment and workflow requirements.


Frequently Asked Questions About Class I Biological Safety Cabinet LB-10BSC

1. What protection capability does Labotronics LB-10BSC provide?
    It provides personnel and environmental protection from airborne biological contaminants.

2. Does this cabinet maintain sample sterility?
    No, the cabinet does not provide product protection because room air enters the workspace.

3. Which biosafety levels commonly use this cabinet?
    It is suitable for BSL-1 and BSL-2 laboratory environments.

4. How does the airflow system operate?
    Air enters through the front opening, passes through HEPA filtration, and is safely exhausted.

5. Is UV sterilization included in the cabinet?
    Yes, the system includes an integrated UV lamp for workspace decontamination.

6. Can airflow velocity be adjusted?
    Yes, airflow settings can be adjusted for containment operation.

7. What maintenance procedures are recommended?
    Routine HEPA filter inspection, airflow testing, and workspace cleaning are recommended.

8. Does the cabinet comply with biosafety standards?
    Yes, it aligns with NSF/ANSI 49 and EN 12469 laboratory biosafety standards.

Typical Application Scenarios

  • Microbiological laboratory testing

  • Non-sterile biological sample preparation

  • Aerosol-generating laboratory procedures

  • Biosafety teaching and training workflows

  • Environmental containment in research laboratories


Compliance and Standards

Labotronics LB-10BSC aligns with:

  • NSF/ANSI 49 – Biosafety Cabinetry Design and Performance

  • EN 12469 – Microbiological Safety Cabinet Standards

  • BSL-1 and BSL-2 laboratory containment practices


Internal Linking Opportunities

Section

Suggested Links

Parent Category

Biological Safety Cabinets Class I

Related Products

Class II Biological Safety Cabinet LB-20BSC, Laminar Flow Cabinet LB-12LFC

Buying Guides

How to Choose the Right Biological Safety Cabinet for Your Laboratory

Technical Articles

Understanding HEPA Filtration in Biosafety Cabinets


Comparison Table

Feature

Class I BSC

Class II BSC

Laminar Flow Cabinet

Protection Type

Personnel & environment

Personnel, product & environment

Product only

Airflow

Inward airflow

Vertical laminar + HEPA

Laminar airflow

Sample Protection

No

Yes

Yes

Application

Biohazard containment

Sterile biological workflows

Sterile operation


Quick Summary

Class I Biosafety Cabinet LB-10BSC is a laboratory containment system designed for personnel and environmental protection during handling of low- to moderate-risk biological materials. It uses inward airflow, HEPA-filtered exhaust, and negative pressure operation to reduce aerosol exposure during laboratory procedures. With UV sterilization, airflow monitoring, stainless-steel workspace configuration, and biosafety compliance capability, it is suitable for microbiology laboratories, pharmaceutical research facilities, diagnostic centers, and academic laboratories operating under BSL-1 and BSL-2 conditions.