Reid Vapor Pressure Bath LB-10RVP is a laboratory system designed for precise measurement of vapor pressure in petroleum products, gasoline, and volatile hydrocarbons. It maintains a controlled temperature environment for vapor-liquid equilibrium testing as per ASTM D323, ensuring accurate fuel volatility analysis for quality control and certification.
Labotronics LB-10RVP is used to measure the vapor pressure of petroleum fuels and volatile liquids under controlled laboratory conditions.
It is used for:
Measuring vapor pressure of gasoline and hydrocarbons
Evaluating fuel volatility and composition stability
Supporting ASTM D323 compliance testing
Assessing fuel storage and handling safety
Studying vaporization behavior of petroleum products
It ensures accurate fuel quality evaluation and regulatory compliance.
This system is widely used in petroleum and analytical testing environments, including:
Petroleum Refineries – fuel certification and quality control
Oil & Gas Laboratories – hydrocarbon volatility analysis
Automotive Testing Centers – fuel performance and emissions studies
Chemical Laboratories – volatile liquid characterization
Environmental Testing Facilities – vaporization and contamination analysis
These industries rely on accurate vapor pressure measurement for safe and standardized fuel evaluation.
Reid Vapor Pressure Bath LB-10RVP system operates by maintaining a precise constant temperature environment (typically 37.8°C / 100°F) for equilibrium-based vapor pressure testing.
Result: Standardized and highly accurate vapor pressure readings.
Temperature range: Ambient to +100°C
Accuracy: ±0.1°C (PID controlled)
10-liter stainless steel bath
Circulation flow rate: 10 L/min
Multi-vessel testing capability (1–2 samples)
Over-temperature and low-fluid protection
LED digital display system
ASTM D323 and IP 69 compliant
Key Insight: LB-10RVP is ideal for compact laboratories and single to low-volume vapor pressure testing workflows.
Controlled temperature range up to +100°C
High-precision PID control (±0.1°C)
Uniform circulation system for thermal stability
Stainless steel corrosion-resistant chamber
Multi-sample testing support
Safety systems for over-temperature and low water protection
Compliance with ASTM D323, IP 69, ISO/IEC 17025
Choose this model when:
You need compact vapor pressure testing setup
Testing is performed under ASTM D323 conditions
Low to medium sample throughput is required
Space-saving laboratory equipment is preferred
High accuracy and repeatability are essential
Ideal for research labs, small refineries, and quality control units.
Constant Temperature Water Baths → fuel conditioning
Evaporation Loss Baths → volatility loss testing
Low Temperature Baths → sub-ambient fuel behavior testing
Kinematic Viscosity Baths → fluid flow property analysis
What is Labotronics LB-10RVP used for?
It is used to measure vapor pressure of gasoline and petroleum products under ASTM D323 conditions.
What is the operating temperature?
It operates from ambient to +100°C, typically at 37.8°C (100°F).
How accurate is the temperature control?
It provides ±0.1°C accuracy using PID control.
Can multiple samples be tested?
Yes, it supports 1–2 test vessels depending on configuration.
Which industries use it?
It is used in petroleum refineries, fuel testing labs, and environmental analysis facilities.
ASTM D323 – Vapor pressure of petroleum products
IP 69 – Reid vapor pressure testing method
ISO/IEC 17025 – Laboratory competence standard
Reid Vapor Pressure Bath LB-10RVP is used for measuring vapor pressure of gasoline, petroleum products, and volatile hydrocarbons under controlled conditions. It operates from ambient to +100°C with ±0.1°C accuracy using a PID-controlled system for stable thermal equilibrium.
It is widely used in petroleum refineries, chemical laboratories, and environmental testing facilities for fuel volatility analysis, ASTM D323 compliance, and quality control testing, offering a compact and efficient solution for low-volume vapor pressure testing.
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026