Multi-gas analyzer LB-25MA is a portable analyzer designed for measurement, analysis, monitoring and control of gas output. Equipped with four gas detector sensors for oxygen, combustibles, hydrogen sulfide and carbon monoxide. The Acrylonitrile – Butadiene- Styrene body shell is temperature-chemical resistant and durable at low temperatures.
Specifications
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Operating temperature | ( -10 °C to 40 °C ) |
Display panel | 2 + 2 digit LCD display |
Data storage | 9600 pieces data record |
Pumping tube length | - |
Alarm system | Audible ( > 90 dB ) Bright dual color LEDs Integrated vibrating alert |
Alarm error | ≤ ± 3 % |
Body shell material | Acrylonitrile – Butadiene- Styrene polymer, slip silicone |
Battery life ( rechargeable ) | 10 + hours |
Power supply | 3.7 V Li battery |
Dimensions ( W x H x D ) | 70 x 38 x 132 mm |
Weight | 300 g |
Features
Applications
Used for the measurement and analysis of gas output or leakage in ceramic, iron-steel industry, thermal treatment, electronic, agricultural, biochemical facilities for environmental pollution regulation
Standard Accessories
Accessory No | Accessory | Units |
1) | Operator’s manual | 1 |
2) | Detection probe | 1 |
3) | Calibration hose | 1 |
4) | USB cable | 1 |
5) | Charger | 1 |
6) | Conversion plug | 1 |
Catalog
Dowload PDF CatalogSensor | High sensitivity sensor |
Sampling method | Pump aspiration |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Pump aspiration |
Detection range | H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Gas detection | THC, CO2, CO, NOX, SO2 |
Sensors | Electrochemistry: CO,NOX,SO2 Infrared Ray: CO2 PID: THC |
Measuring range | THC: 0 to 10000 ppm CO2: 0 to 20% VOL CO: 0 to 10% VOL NOX: 0 to 5000 ppm SO2: 0 to 5000ppm |
Resolution | THC,NOX,SO2: 1 ppm CO2,CO: 0.01% VOL |
Categories
Get In Touch
Address :
Labotronics Ltd.
Union House, 111 New Union Street,
Coventry CV1 2NT, UK
Phone:
0333 011 6305WhatsApp:
+44 7888 870058Email:
info@labotronics.com