Atmospheric Distillation Tester LB-12APDT

Atmospheric Distillation Tester LB-12APDT

Atmospheric Distillation Tester LB-12APDT operates with a distillation rate of 4 to 5 ml per minute and offers a sample capacity ranging from 150 to 200 ml. It is equipped with a condensate bath and cooling bath system, ensuring efficient condensation and rapid cooling. It features a 50 mm furnace volume, allowing controlled movement for optimal heating. Our distillation tester has digital temperature control, providing precise and accurate temperature regulation.

$ 4200

Download Catalog

Specifications

Sample Capacity 150 to 200ml
Distillation Rate 4 to 5ml per minute
Ambient Temperature Range 10℃ to 35℃
Ambient Humidity Level ≤85%
Condensate Bath Temperature Range -5℃ to 80℃
Cooling Bath Temperature Range -5℃ to 80℃
Air Bath Temperature Range 0℃ to Room Temperature (Ice can be added)
Temperature Accuracy ±0.1℃
Distillate Heating Range 0 to 1200W (Continuously Adjustable)
Furnace Volume 50 mm (Movements Adjustable)
Flask Branch Aperture Plate One Φ50mm and two Φ37.5mm
Stirring Mode Condensing bath stirred by motor
Power Supply AC220V ±10%, 50Hz
Dimension 850 × 600 × 720 mm
Net Weight 86 kg
Gross Weight 92 kg

Features

  • Complies with ASTM D86

  • Adjustable heating power

  • Dual cooling system

  • Anti-splash protection

  • Anti-electric shock

  • Stable and consistent distillation rate

Standard Accessories

Rubber Plug × 6 pcs

Graduated Cylinder × 2 pcs

25A Fuse × 2 pcs

Thermometer (0 to 100°C) × 1 pc

Thermometer (−200 to 300°C) × 2 pcs

Thermometer (−200 to 400°C) × 2 pcs

Flask × 2 pcs

Φ37.5 and Φ50 Furnace Mat × 2 pcs Each

Applications

Atmospheric Distillation Tester LB-12APDT is used for precise distillation and separation of petroleum products, chemical solvents, and similar samples. It widely used in research laboratories, quality control departments, chemical industries, and petroleum testing facilities.

Atmospheric Distillation Tester LB-12APDT
Atmospheric Distillation Tester LB-12APDT

Get Quote

Atmospheric Distillation Tester

Test temperature - 40 °C ~ 70 °C
Sample size 100 mL
Distillation rate 4 mL/min ~ 5 mL/min
Ignition gas Pipe gas or LPG
pressure ≤ 10 kPa
Temperature Range RT to 400℃
Temperature Accuracy ± 0.1℃
Ambient Temperature Range 10 to 40℃
Storage Temperature Range 0 to 50℃
Sample Capacity 100 ml
Temperature Range RT to 400℃
Left Bath Temperature Range 0 to 60℃
Left Bath Temperature Accuracy ±0.5℃
0
×

Ask Quote