Generate Catalog For:

Inductively Coupled Plasma Mass Spectrometer LB-10ICPMS Catalog

Overview

Inductively Coupled Plasma Mass Spectrometer LB-10ICPMS provides a mass range from 2 to 260 amu for precise analysis of trace elements. It utilizes argon plasma to ionize samples, ensuring high ionization efficiency. It features an ETP detector and hexapole cell, ensuring accurate trace analysis by removing polyatomic interferences. Our spectrometer facilitates automated PC-controlled counting and stable plasma operation for high-sensitivity analysis.

Specifications :
Mass Range 2 to 260 amu
Testing Range ≥ 108
Sensitivity Be ≥ 2 × 10⁶ (cps/mg/L)
In ≥ 35 × 10⁶ (cps/mg/L)
U ≥ 30 × 10⁶ (cps/mg/L)
Detection Limit Be ≤ 10
In ≤ 2
U ≤ 2 (ng/L)
Resolution 0.6 to 0.8 amu
Isotope Ratio ≤ 0.3% (107Ag/109Ag)
SNR ≥ 50 × 10⁶ (Signal-to-Noise Ratio)
Quality Axis Stability ≤ 0.05 amu/24 h
Stability RSD Short term ≤ 3%
Long term ≤ 4%
Oxide Ion ≤ 3%
Double Charged Ion ≤ 3%
Background Noise ≤ 2 cps (full quality range)
Abundance Sensitivity ≤ 1 × 10⁻⁶ (low-quality end)
≤ 5 × 10⁻⁷ (high quality end)
Plasma Ion Source Argon plasma
Collision Cell Hexapole collision cell
Detector Electron multiplier - ETP double-mode detector, electron multiplier with dynodes arranged in two parts
Mass Spectrometer Unit Quadrupole mass spectrometer
Autosampler Total: 250 cups, 50mL (10) + 15mL (240)
Gas Used He/H2 and He/NH3 at 0 to 10mL/min
Sample Spray Chamber Impact bead chamber (electronically cooled), quartz
Peristaltic Pump 3-channel
Plasma Torch One-piece quartz torch, 1.5mm injector
Vacuum System 3 stages, with isolated turbopumps
Counting and Analog Switch PC controlled
Chiller Connection Kit Yes
High-Frequency Output 1.6KW
High-Frequency Power Supply 27 MHz, Solid state
Cooling Water Single-phase 200 to 230 V, 50/60 Hz, 2 kW
Power Supply Single-phase 200 to 240 V ± 10%, 50/60 Hz, 6 Kw
Dimension 1300 × 700 × 800 mm
Gross Weight 400 kg
Features :

  • High ionization efficiency
  • Ultra-trace detection
  • Stable axis calibration
  • Flexible sampling options
  • Advanced signal processing
  • Durable construction
  • Low background noise

Standard Accessories :

Glove Box


PC Cable
Reducing Valve
Bellows
Radial Spring Clamp
Sealing Ring
PU Tube
Peristaltic Pump Head Hose
Polyurethane Hose
Peristaltic Pump Tubing
Exhaust Pipe
Ethernet Cable
Mechanical Pump
Vacuum Clamp
Plastic Box
Allen Wrench
Ball Allen Wrench
Double-Ended Wrench
Adjustable Wrench
Flat-Blade Screwdriver
Tweezers
Phillips-Screwdriver
Cooling Water Tank
Flash Storage

Optional Accessories :

Collision Pool Components


Autosampler

Applications :

Inductively Coupled Plasma Mass Spectrometer LB-10ICPMS is ideal for detecting trace elements, conducting food safety testing, and analyzing ultra-trace impurities in semiconductor materials. It also plays a crucial role in medical diagnostics and nuclear monitoring of radioactive elements.