Automatic Cleveland Open Cup Flash Point Tester LB-20CFP

Automatic Cleveland Open Cup Flash Point Tester LB-20CFP

Automatic Cleveland Open Cup Flash Point Tester LB-20CFP is a micro controller system. It is designed in accordance with ASTM D92 and thermocouple differential detection testing method. The electronic mode of ignition promotes conventional use of energy. The adaptive PID control algorithm automatically adjusts the heating curve initiated by electric ignition. It is equipped with high speed thermal printer for quick result printing.

Buy Now Download Catalog

Specifications

Testing range RT ~ 400 °C
Ignition mode Automatic electronic
Temperature detection Precision platinum resistance
Repeatability ± 2 °C
Ambient temperature 10 °C ~ 45 °C
Relative humidity 30 % ~ 80 %
Power consumption < 700 W
Power supply AC 220 V ± 10 %
Dimensions 400 × 300 × 240 mm
Weight 20 kgs

Features

  • Digital color touch screen LCD
  • Airless ignition by platinum alloy for stable and high precision results
  • High speed signal processor with precise simulation and digital converter circuit
  • In-built automatic atmospheric pressure detector
  • Data storage function for up to 300 groups
  • Over temperature detection and alert indication
  • Auto stirring, ignition, testing, alerting, cooling and printing

Applications

Used in fields of petroleum, chemicals, power station, environmental analysis, railways, scientific research, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Diekolola Enuma logo

2 years ago

Thatre Deeprasert logo

3 months ago

Ing. Amálie Kosinová logo

1 year ago

Dharwish Mohaideen logo

1 year ago

Gyan . logo

2 years ago

Nizar Salhieh logo

1 year ago

Mazen Darwish logo

1 year ago

Svetlana Zozina logo

1 year ago

Aliaksandr Kisel Kisel logo

1 year ago

Michael Aravind logo

1 year ago

Fatima Jahaf logo

2 months ago

Jhantu 17-02-2023 logo

1 year ago

Emad Alesawey logo

5 months ago

NGUYEN CHI NGHIA logo

9 months ago

Dr.Islam Khamis logo

2 months ago

Gokul R.S logo

1 year ago

Ashwin Sacheendran logo

5 months ago

T. Chandrakumar logo

1 year ago

Tirthankar Bhandary logo

1 year ago

Manish . logo

2 years ago

Sajjad Hussain logo

1 year ago

Adel Qatanani logo

1 year ago

Add a review

Cleveland Open Cup Flash Point Tester

Cleveland Open Cup Flash Point Tester : Cleveland Open Cup Flash Point Tester LB-11CFP
Ignition method Remote control
Ignition gas Pipe gas or LPG
Measuring range 90 °C ~ 400 °C
Test temperature
Cleveland Open Cup Flash Point Tester : Cleveland Open Cup Flash Point Tester LB-12CFP
Ignition method Automatic
Ignition gas
Measuring range 90 °C ~ 400 °C
Test temperature
Cleveland Open Cup Flash Point Tester : Cleveland Open Cup Flash Point Tester LB-10CFP
Ignition method Manual
Ignition Device Fire Source: Gas
Power 0 W to 600 W, continuous adjustable
Heating Device Quartz tube furnace heating

Our foaming characteristic tester is a specialized instrument used in the petroleum industry to evaluate the foaming properties of lubricating oils. It measures the foaming tendency and stability of the oil under controlled conditions, simulating the dynamic conditions within engines. The tester typically involves agitating the oil sample to induce foam formation, and the resulting foam height and stability are observed. Foaming Characteristic Testers are essential for quality control and research and development, helping to ensure that lubricating oils meet industry standards and specifications, ultimately contributing to the reliability and longevity of machinery and engines.

Temperature control point 150 °C ± 0.5 °C
Bath stir Motor stirring
Accuracy
Agitation mode
Temperature control point
Bath stir
Accuracy
Agitation mode
Temperature control point 24 °C 93.5 °C
Bath stir
Accuracy ± 0.5 °C
Agitation mode Electrical

Our petroleum density tester is a specialized instrument used in the petroleum industry to measure the density of liquid fuels and other hydrocarbon-based products. This crucial parameter is indicative of the mass per unit volume and is essential for quality control and compliance with industry standards. The tester typically employs the oscillating U-tube principle, where the sample is introduced into a vibrating U-tube filled with a reference liquid. The frequency of oscillation changes with the density of the sample, allowing for accurate density determination.

Measuring cylinder capacity 1000 mL
Bath temperature 20 °C ~ 95 °C
No of testing holes 2
Mixing method Mixing motor 1200 r/min
Temperature Range 0 °C to 100 °C
Temperature Accuracy ± 0.1 °C
Temperature Sensor PT100 platinum resistance
Thermometer Least Count 0.2 °C
Measuring cylinder capacity
Bath temperature
No of testing holes 2
Mixing method

Our Dropping Point Tester is a specialized laboratory instrument designed to determine the dropping point of lubricating greases. This crucial parameter signifies the temperature at which the grease undergoes a transition from a semi-solid to a liquid state. Operating on the principle of heating a sample and observing the point at which a standard cone penetrates the softened grease, the tester ensures precise measurement of dropping points. Widely used in industries like automotive and machinery, this tester provides essential information about the temperature range within which a grease can effectively lubricate moving parts.

Temperature control range
Temperature control accuracy
Temperature control point
Glass bath capacity 800 mL
Temperature Control Range 400℃
Temperature Control Point 121℃,232℃,288℃,343℃
Temperature control accuracy ± 3℃
Grease Cup Material Chrome plated copper
Temperature control range
Temperature control accuracy
Temperature control point
Glass bath capacity

Octane and Cetane Tester is a specialized instrument used in the petroleum and automotive industries to determine the octane rating of gasoline and the cetane number of diesel fuels, respectively. It plays a crucial role in quailty control and research, ensuring that fuels meet specified standards for combustion performance. The tester typically operates by subjecting a fuel sample to controlled conditions in a test engine and analyzing its ignition characteristics. For gasoline, the octane rating indicates resistance to pre-ignition, while the cetane number in diesel fuel correlates with ignition delay. These parameters are vital for optimizing engine performance, preventing knocking or excessive emissions.

Type Portable
Measuring Method RON and MON
Octane Gasoline Measurement Range 40 to 125 ON
Octane Accuracy ± 0.5

Labotronics ash content tester is a laboratory instrument used to determine the inorganic residue content in a given sample, typically in materials like plastics, polymers, and organic compounds. It works by subjecting the sample to high temperatures, burning off the organic components, and leaving behind the inorganic ash residue. This test is essential for quality control and research and development in various industries, including pharmaceuticals, food, and materials manufacturing. Our ash content measurement provides insights into the purity and composition of materials, aiding in material selection, product development, and ensuring compliance with industry standards and regulations.

Temperature range RT ~ 1000 °C
Air furnace heating time ≤ 60 min
Temperature uniformity ≤ 15 °C
Temperature control 775 °C ± 25 °C