Double Beam UV-Visible Spectrophotometer LB-11DBS offers a wavelength range of 190 to 1100 nm, ensuring precise and accurate spectral analysis of samples. It has double beam optical system and uses a 1200 lines/mm diffraction grating for high-resolution spectral separation. It employs an imported silicon photodiode detector for fast and accurate signal conversion. Our spectrophotometer features a 7-inch color LCD screen for intuitive control and clear display of results.

$ 12650

Download Catalog

Specifications

Wavelength Range 190 to 1100 nm
Spectral Bandwidth 1 nm
Wavelength Accuracy ±0.1 nm at 656.1 nm, ±0.3 nm (all)
Wavelength Repeatability ≤ 0.1 nm
Photometric Range 0 to 200%T, -0.3 to 3A, 0 to 9999C
Photometric Accuracy 0.2% T (0 to 100% T); ±0.002A (0 to 0.5A); ±0.004A (0.5 to 1A)
Photometric Repeatability ≤ 0.15% T (0 to 100% T); 0.001A (0 to 0.5A); 0.002A (0.5 to 1A)
Optical system Single Beam, Grating 1200 lines/mm
Stray Light ≤0.03% T at 220 nm, 360 nm
Stability ±0.0005 A/h at 500 nm
Baseline Flatness ±0.001 A
Work Modes T, A, C, E
Scanning Speed High, Medium, Low (Maximum 3000 nm/min)
Display 7-inch Colorscreen
Light Source Deuterium & Tungsten Lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10 mm manual 4-cell holder
Communication Interfaces USB drive, USB host, RS232
Noise level 0.0005 A at 500 nm
Power Supply AC 110-220 V, 50/60 Hz
Product Dimension 590 × 470 × 250 mm
Packaging Dimension 810× 660 × 390 mm
Net Weight 20 kg
Gross Weight 27 kg

Features

  • Windows-style interface
  • Multi-parameter testing
  • Easy lamp switching
  • Low stray light
  • Multiple scan speeds
  • Manual cuvette holder
  • Low noise level

Standard Accessories

10mm Glass Cuvette × 4 pcs

10mm Quartz Cuvette × 2 pcs

Power cord

PC software

Optional Accessories

5 mm glass cuvettes × 4 pcs/box
20 mm glass cuvettes × 2 pcs/box
30 mm glass cuvettes × 2 pcs/box
50 mm glass cuvettes × 2 pcs/box
100 mm glass cuvettes × 2 pcs/box
5 mm quartz cuvettes × 2 pcs/box
20 mm quartz cuvettes × 2 pcs/box
30 mm quartz cuvettes × 2 pcs/box
50 mm quartz cuvettes × 2 pcs/box
100 mm quartz cuvette × 1 pcs/box
0.35/0.7/1.0/1.4/1.7 ml Quartz micro-cuvettes × 2 pcs/box
50/100/200 µl Quartz micro-cuvettes  × 2 pcs/box
0.35/0.7/1.0/1.4/1.7 ml Glass micro-cuvettes × 2 pcs/box
50/100/200 µl Glass micro-cuvettes × 2 pcs/box
10 mm Manual 4-Cell Holder 
50 mm Manual 4-Cell Holder 
100 mm Manual 4-Cell Holder 
10 mm Single Hole Cell Holder 
50 mm Single-Hole Long-Path Cell Holder 
100 mm Single-Hole Long-Path Cell Holder 
Auto 4-Cell/5-Cell/8-Cell Holder
Film Holder
Tube Rack
Adjustable XY Micro Holder
Peltier/Sipper System
Integrating Sphere
1000 Tungsten Lamp 
1200/1600/1700/1800/1900/N/K/X/T Tungsten Lamp
1000/1200 Deuterium Lamp
1600/1700/1800/1900/N/K/X/T Deuterium Lamp
Xenon Lamp
Thermal Printer
Built-In Thermal Printer
1000/1200 PC Software
1600/1700/1800/1900/N/K/X/T/M PC Software
1600/1700/1800/1900/N/K/X/T/M 21-CFR Software

 

Solution Standards: 

500 ml Chloride Standard Solution (1000 mg/L concentration) 

500 ml Silica Standard Solution 

500 ml Iron Standard Solution 

500 ml Sulphate Standard Solution (Sulfuric Acid-based)

Applications

Double Beam UV-Visible Spectrophotometer LB-11DBS is used for photometric, quantitative, kinetic studies, spectrum scanning, and DNA/protein testing of samples. It is widely used in research laboratories, medical diagnostics, environmental analysis, and food quality control.

Double Beam UV-Visible Spectrophotometer LB-11DBS Banner
Double Beam UV-Visible Spectrophotometer LB-11DBS Banner

Get Quote

Frequently asked questions For Double Beam UV-Visible Spectrophotometer

1. What types of samples can the Labotronics LB-11DBS spectrophotometer analyze?

Labotronics LB-11DBS can analyze liquids, solutions, biological samples like DNA and proteins, and materials used in environmental, food, and pharmaceutical testing.

2. Can the LB-11DBS perform different testing methods?

Yes, it supports photometric, quantitative, kinetic, and spectrum scanning modes, making it ideal for various analytical applications in laboratories.

3. Why does the LB-11DBS use both Deuterium and Tungsten lamps?

Labotronics' LB-11DBS combines Deuterium and Tungsten lamps to cover a broad wavelength range from 190 to 1100 nm, ensuring accurate analysis across ultraviolet and visible light spectra.

4. How do I maintain accurate wavelength calibration on the LB-11DBS?

Our LB-11DBS delivers precise wavelength accuracy and repeatability, and regular calibration with standard solutions helps maintain consistent and reliable results.

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Double Beam UV-Visible Spectrophotometer

Double Beam Uv-Visible Spectrophotometer LB-14DBS

Optical system Double beam
Wavelength range 190 nm ~ 1100 nm
Spectral bandwidth 0.5 nm, 1 nm, 2 nm, 5 nm
Stray light ≤ 0.04 T at 360 nm; 220 nm
Wavelength accuracy ± 0.3 nm

$ 73375

Double Beam UV-Visible Spectrophotometer LB-12DBS

Optical system Double beam
Wavelength range 190 nm ~ 1100 nm
Spectral bandwidth 1 nm
Wavelength accuracy ± 0.1 nm (D2 656.1 nm), ± 0.3 nm (full wavelength range)
Wavelength repeatability 0.1 nm

$ 126125

Double Beam UV-Visible Spectrophotometer LB-20DBS
Wavelength range 190 to 1100 nm
Spectral bandwidth 0.5 nm, 1 nm, 2 nm, 4 nm, and 5 nm
Focal length 200 mm
Optical system Double beam, Czerny-Turner monochromator, 1600 lines/mm grating
Wavelength accuracy ±0.3 nm

$ 5625

Double Beam UV-Visible Spectrophotometer LB-21DBS
Optical System Double Beam
Bandwidth 1 nm
Cell Holder 2-position; 1 cm cell holder
Grating Holographic grating; 1200 lines/mm
Wavelength Range 190 to 1100 nm

$ 92875

Double Beam UV-Visible Spectrophotometer LB-13DBS

Optical system Double beam
Wavelength range 190 nm ~ 1100 nm
Spectral bandwidth 1.8 nm
Stray light ≤ 0.04 T at 360 nm; 220 nm
Wavelength accuracy ± 0.3 nm

$ 60875

Double Beam UV-Visible Spectrophotometer LB-10DBS

Optical system Double beam
Wavelength range 190 nm ~ 1100 nm
Spectral bandwidth 2 nm
Wavelength accuracy ± 0.1 nm
Wavelength repeatability 0.1 nm

$ 77125