Drying Cabinet LB-64DC provides a generous 870L capacity with an ultra-low humidity range of less than 3% RH, ensuring optimal storage for sensitive electronics. This cabinet delivers fast humidity recovery for a stable, low-humidity environment. It has five adjustable shelves, each capable of holding up to 100 kg for flexible storage. Our drying cabinet is equipped with high-precision temperature and humidity sensors to reliably monitor storage conditions.
$ 4818.75
Download CatalogSpecifications
| Capacity | 870L |
| Humidity Range | < 3% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Material | 1.2 mm thick galvanized steel with ESD-safe coating |
| Power Consumption | 15W |
| Inner Dimension (W × D × H) | 898 × 572 × 1698 mm |
| Outer Dimension (W × D × H) | 900 × 600 × 1890 mm |
| Net Weight | 110 kg |
| Gross Weight | 130 kg |
Features
Automatic humidity control
High load capacity
ESD-safe coating
Tempered glass window
Secure locking system
Low maintenance
Optional Accessories
Over-Humidity Buzzer Alarm
Open Door Buzzer Alarm
Three-Color Flashing Light Alarm
Data Logging System with USB Interface
Extra Shelf
Applications
Drying Cabinet LB-64DC is ideal for precise and secure storage of moisture-sensitive electronics components. It is widely used in electronics manufacturing, semiconductor industries, laboratories, and research facilities.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 718L |
| Humidity Range | < 3% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 718L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 165 L |
| Humidity Range | 15 to 50 % RH |
| Display Precision | + 3% RH, +1°C |
| Shelves | 3 shelves |
| Ambient Conditions | Temperature below 30°C Relative humidity below 60%RH |
| Capacity | 435L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 3pcs (Height adjustable) |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 320L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 240L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 3pcs (Height adjustable) |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 160L |
| Humidity Range | < 3% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 98L |
| Humidity Range | < 10%RH Automatic |
| Number of Shelves | 1pc |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 718L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 870L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 540L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 98L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 1pc (Height adjustable) |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026