Electrolyte Analyzer LB-11ELA offers a sample capacity of 300 µL, ensuring rapid and accurate analysis of critical electrolytes and blood gases. It utilizes advanced ion-selective electrode (ISE) technology for high-precision measurements. Its direct measurement method eliminates dilution steps, enhancing test speed and reliability. Our analyzer features a graphic lattice LCD, providing a clear and intuitive interface for navigating test results and system settings.
$ 3750
Download CatalogSpecifications
| Test Parameters | K, Na+, Cl-, Ca2+, pH(H+), Li+, TCO2 |
| Test Range | K+ - 1.00mmol/L to 16.0mmol/L Na+ - 30.0 mmol/l to 200.0 mmol/L Cl- - 30.0 mmol/l to 200.0 mmol/L Ca++ - 0.50 mmol/l to 5.00 mmol/L TCo2 - 5.0 mmol/l to 60.0 mmol/L pH - 6.00 to 9.00 Li + - 0.3 to 3mmol/L |
| Test Resolution | K+ - 0.01 mmol/L Na+ - 0.1 mmol/L Cl- - 0.1 mmol/L Ca++ - 0.01 mmol/L TCo2 - 0.1 mmol/L pH - 0.01 Li + - 0.01 mmol/L |
| Test Principle | Ion selective electrode |
| Test Method | Direct method |
| Sample Capacity | 300 µL |
| Calibration Mode | Manual + Automatic |
| Display | Graphic lattice LCD |
| Communication Interface | RS-232CSerial interface |
| Data storage | ≥ 1000 samples |
| Product Dimension | 380 × 270 × 400 mm |
| Packaging Dimension | 500 × 420 × 565 mm |
| Net weight | 8 kg |
| Gross weight | 9 kg |
Features
Multi-parameter testing
High test resolution
Auto/manual calibration
Rs-232c interface
Large data storage
User-friendly interface
Built-in diagnostic system
Standard Accessories
Optional Accessories
| Reagent | Volume |
| Reagent A - Calibrating Solution | 480ml |
| Reagent B - Slope Solution | 200ml |
| Pipe Electrode Rinsing Solution | 10ml |
| Electrode Internal Filling Solution | 10ml |
| Reference Electrode Internal Filling Solution | 10ml |
Applications
Electrolyte Analyzer LB-11ELA is used to measure electrolytes and pH levels in blood samples, helping evaluate fluid balance and organ function. It is widely used in hospitals, ICUs, emergency departments, and clinical laboratories for patient diagnosis and monitoring.
Frequently asked questions For Electrolyte Analyzer
1. What is the primary function of a Labotronics Electrolyte Analyzer?
A Labotronics Electrolyte Analyzer is designed to measure key electrolytes such as sodium, potassium, chloride, and others in blood, serum, or plasma for accurate clinical diagnostics.
2. How do Labotronics Electrolyte Analyzers ensure accurate and ion-specific testing?
Labotronics Electrolyte Analyzers use advanced ion-selective electrode (ISE) and dry electrochemical technologies to deliver precise, ion-specific measurements across various biological samples.
3. Can Labotronics Electrolyte Analyzers handle multiple parameters in one test?
Yes, Labotronics electrolyte analyzers are capable of multi-parameter testing, allowing simultaneous measurement of several electrolytes in a single sample run.
4. How do Labotronics Electrolyte Analyzers help reduce contamination risks during testing?
Labotronics electrolyte analyzers feature closed-system operation with automated flushing and calibration, minimizing the chance of cross-contamination between samples.
5. Are Labotronics Electrolyte Analyzers portable for use in mobile or point-of-care settings?
Yes, select Labotronics electrolyte analyzers are compact and battery-powered, making them ideal for use in mobile clinics, fieldwork settings, and bedside diagnostics.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Sample Type | Whole blood, serum, plasma, diluted urine |
| Sample Volume | 100 µL to 150 µL |
| Throughput | Up to 60 samples/hour |
| Measuring Range | K⁺: 0.50 to 15.00 mmol/L Na⁺: 30.0 to 200.0 mmol/L Cl⁻: 30.0 to 200.0 mmol/L Ca²⁺: 0.10 to 5.00 mmol/L pH: 4.0 to 9.50 (Unit) CO₂: 6.0 to 50.0 mmol/L |
| Precision | K⁺ ≤ 1.0% (CV%) Na⁺ ≤ 1.0% Cl⁻ ≤ 1.0% Ca²⁺ ≤ 3.0% pH ≤ 2.0% CO₂ ≤ 3.0% |
| Sample Types | Venous whole blood, plasma, and serum |
| Test Parameters | K+, Na+, Cl-, iCa2+, iMg2+ |
| Testing Principle | Electrochemistry/Microfluidic method |
| Blood Sample Capacity | 110 µL |
| Temperature Range | 10°C to 30°C |
| Test Parameters | K⁺, Na⁺, Cl⁻, Ca²⁺, pH, TCO₂ |
| Calculated Parameters | nCa, TCa, AG |
| Measuring Method | Ion Selective Electrode Method |
| Blood Measuring Range | K⁺ - 0.50 to 15.00 mmol/L Na⁺ - 30.0 to 200.0 mmol/L Cl⁻ - 30.0 to 200.0 mmol/L Ca²⁺ - 0.10 to 5.00 mmol/L pH - 4.0 to 9.0 mmol/L TCO₂ - 4.0 to 70.0 mmol/L |
| Blood Accuracy | K⁺, Na⁺, Cl⁻: ≤ ±3.0% Ca²⁺: ≤ ±5.0% or 0.05 mmol/L pH: ≤ 0.15 TCO₂: ≤ 3.0 mmol/L |
| Sample Types | Venous whole blood, serum |
| Sample Volume Range | 80 µL to 120 µL |
| Throughput | Up to 55 samples in a row |
| Test Parameters | K⁺, Na⁺, Cl⁻, Ca²⁺, pH, Li⁺, tCO₂ |
| Testing Range | K+ - 1.00mmol/L to 16.0mmol/L Na+ - 30.0 mmol/l to 200.0 mmol/L Cl- - 30.0 mmol/l to 200.0 mmol/L Ca++ - 0.50 mmol/l to 5.00 mmol/L TCo2 - 5.0 mmol/l to 60.0 mmol/L pH - 6.00 to 9.00 Li + - 0.3 to 3mmol/L |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026