ELISA workstation LB-10ELISA is a fully automated immunoassay processor with multifunctional liquid handling system. It is characterized with the unique module combination of pipetting, washing, incubating and reader functions. The dispense channels feature disposable tips to avoid contamination. The workstation employs dispensing-aspirating washing mode.
$ 27650
Download Catalog Download ManualSpecifications
| Assembly | Benchtop |
| Number of channels | 1 |
| Disposable tips | 300 µL and 800 µL |
| Pipetting range | 5 µL ~ 800 µL |
| Pipetting increment | 0.1 µL |
| Pipetting precision and accuracy (300 µL and 800 µL) | Volume: 100 µL Accuracy: ± 1% Precision: < 0.75 % |
| Liquid Handling Speed | 130 sec for pipetting 100 µL into 96 wells (including tip exchange); 160 sec without tip exchange |
| Liquid Handling Functions | Pipetting, dispensing, dilution, conjugation, aliquoting, multiple and diversified dispensing |
| Liquid Level Monitoring | Liquid level monitoring, clot monitoring, empty tube monitoring |
| Sample Capacity | 24 × 5 = 120 samples (standard tube diameter 13 mm, Other diameters optional) |
| Reagent Capacity | 4 × 2 = 8 (60 mL) or 4 × 4 = 16 (30 mL) standard reagent positions |
| Plate positions | 2 sample pipetting and dilution positions, 2 × 96-well plates with shake |
| Incubator Type | Dual incubator system with programmable temperature and timing |
| Temperature range | RT to 60 °C |
| Temperature increment | 0.1 °C |
| Temperature accuracy | ± 0.5 °C at 37 °C |
| Washing channels | 1 × 16 |
| Wash volume | 50 µL to 1000 µL per well |
| Residual volume | ≤ 1 µL per well |
| Washing Modes | Dispense-aspirate, overflow washing, crosswise aspiration with selectable injection height, soak time and final aspiration |
| Liquid System | 5 reagent channels and 1 waste aspiration channel with liquid level monitoring; dedicated waste container |
| Measurement Module Type | Photometric microplate reader |
| Measurement System | 8-channel detector, silicon photodiodes, tungsten halogen lamp |
| Wavelength Range | 340 to 850 nm |
| Filter Configuration | 405, 450, 492, 630, 550 nm + 3 optional positions |
| Measurement Range | 0.000 to 6.000 A |
| Measurement Resolution | 0.001 A |
| Measurement Modes | Both single and dual |
| OD Accuracy | ±1% (0.0 to 3.0 A) or ±0.003 A |
| OD Precision | CV ≤ 0.2% (0.3 to 3.0 A) |
| Software | Windows based |
| Safety Alarm Type | Audio Visual |
| Operating Temperature | 18 to 25 °C |
| Operating Humidity | 30 to 60% non-condensing |
| Power Consumption | 300 VA |
| Power Supply | 220 V, 50 to 60 Hz |
| Interface | USB and RS232 |
| Dimensions (W × D × H) mm | 1000 × 650 × 800 mm |
| Weight | 86 kgs |
Features
Optional Accessories
| Accessory Type | Qty |
| IgG Antibodies to Anti-DNA | 96 tests/kit |
| Antibodies to SSA (Anti-RO) | 96 tests/kit |
| Antibodies to SSB (Anti-LA) | 96 tests/kit |
| Antibodies to SM (Anti-SM) | 96 tests/kit |
| Antibodies to RNP (Anti-RNP) | 96 tests/kit |
| Antibodies to SCL70 (Anti- SCL70) | 96 tests/kit |
| Antibodies to JO-1 (Anti-JO-1) | 96 tests/kit |
| IgG Antibodies to MPO | 96 tests/kit |
| IgG Antibodies to PR3 | 96 tests/kit |
| IgG Antibodies to Anti-TPO | 96 tests/kit |
| IgG Antibodies to Anti-TG | 96 tests/kit |
| IgG Antibodies to Anti-CCP II | 96 tests/kit |
| IgG Antibodies to Anticardiolipin | 96 tests/kit |
| IgM Antibodies to Anticardiolipin | 96 tests/kit |
| IgG Antibodies to Anti-β2 Glycoprotein I | 96 tests/kit |
| IgM Antibodies to Anti-β2 Glycoprotein I | 96 tests/kit |
| Antibodies TSH Receptor | 96 tests/kit |
| IgG Antibodies to IA2 | 96 tests/kit |
| IgG Antibodies to GAD | 96 tests/kit |
| IgG Antibodies to PLA2R | 96 tests/kit |
| Conductive tips, 300 µl | 18 packs × 960 tips |
| Conductive tips, 1100 µl | 10 packs × 960 tips |
| Adjustment solution, 50 ml | 18 bottles/box |
| Deepwell plate | 5 plates × 10 packs |
Applications
Used to detect antigens or antibodies in serum, sputum, semen, urine, stool, supernatant of culture in the fields of microbiology, genetic profiling, biotechnology, biochemistry, zoology, clinical trials, etc.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Assembly | Cabinet |
| Number of channels | 8 |
| Disposable tips | 300 µL and 800 µL |
| Pipetting range | 1 µL ~ 1000 µL |
| Pipetting increment | 0.1 µL |
| Assembly | Cabinet |
| Number of channels | 4 |
| Disposable tips | 300 µL and 800 µL |
| Pipetting range | 1 µL ~ 1000 µL |
| Pipetting increment | 0.1 µL |
| Assembly | Cabinet |
| Number of channels | 2 |
| Disposable tips | 300 µL and 800 µL |
| Pipetting range | 1 µL ~ 1000 µL |
| Pipetting increment | 0.1 µL |
| Assembly | Benchtop |
| Number of channels | 1 |
| Disposable tips | 300 µL and 800 µL |
| Pipetting range | 0.5 µL ~ 800 µL |
| Pipetting increment | 0.1 µL |