| Mass Range | 2 to 260 amu |
| Testing Range | ≥ 108 |
| Sensitivity | Be ≥ 2 × 10⁶ (cps/mg/L) In ≥ 35 × 10⁶ (cps/mg/L) U ≥ 30 × 10⁶ (cps/mg/L) |
| Detection Limit | Be ≤ 10 In ≤ 2 U ≤ 2 (ng/L) |
| Resolution | 0.6 to 0.8 amu |
| Isotope Ratio | ≤ 0.3% (107Ag/109Ag) |
| SNR | ≥ 50 × 10⁶ (Signal-to-Noise Ratio) |
| Quality Axis Stability | ≤ 0.05 amu/24 h |
| Stability RSD | Short term ≤ 3% Long term ≤ 4% |
| Oxide Ion | ≤ 3% |
| Double Charged Ion | ≤ 3% |
| Background Noise | ≤ 2 cps (full quality range) |
| Abundance Sensitivity | ≤ 1 × 10⁻⁶ (low-quality end) ≤ 5 × 10⁻⁷ (high quality end) |
| Plasma Ion Source | Argon plasma |
| Collision Cell | Hexapole collision cell |
| Detector | Electron multiplier - ETP double-mode detector, electron multiplier with dynodes arranged in two parts |
| Mass Spectrometer Unit | Quadrupole mass spectrometer |
| Autosampler | Total: 250 cups, 50mL (10) + 15mL (240) |
| Gas Used | He/H2 and He/NH3 at 0 to 10mL/min |
| Sample Spray Chamber | Impact bead chamber (electronically cooled), quartz |
| Peristaltic Pump | 3-channel |
| Plasma Torch | One-piece quartz torch, 1.5mm injector |
| Vacuum System | 3 stages, with isolated turbopumps |
| Counting and Analog Switch | PC controlled |
| Chiller Connection Kit | Yes |
| High-Frequency Output | 1.6KW |
| High-Frequency Power Supply | 27 MHz, Solid state |
| Cooling Water | Single-phase 200 to 230 V, 50/60 Hz, 2 kW |
| Power Supply | Single-phase 200 to 240 V ± 10%, 50/60 Hz, 6 Kw |
| Dimension | 1300 × 700 × 800 mm |
| Gross Weight | 400 kg |
Features
Standard Accessories
Glove BoxOptional Accessories
Collision Pool ComponentsApplications
Inductively Coupled Plasma Mass Spectrometer LB-10ICPMS is ideal for detecting trace elements, conducting food safety testing, and analyzing ultra-trace impurities in semiconductor materials. It also plays a crucial role in medical diagnostics and nuclear monitoring of radioactive elements.Frequently asked questions For Inductively Coupled Plasma Mass Spectrometry
1. What is the primary function of a Labotronics ICP-MS spectrometer?
A Labotronics ICP-MS spectrometer is designed for ultra-trace detection of elements in complex samples using argon plasma and mass spectrometry.
2. How does a Labotronics ICP-MS spectrometer achieve high-sensitivity analysis?
Labotronics ICP-MS spectrometers use argon plasma ionization and ETP double-mode detectors to provide precise and repeatable measurements at trace and ultra-trace levels.
3. Can Labotronics ICP-MS spectrometers handle complex or low-concentration samples?
Yes, Labotronics ICP-MS spectrometers are built to analyze low-concentration elements in highly complex matrices, offering reliable results in sensitive applications.
4. Is calibration and sampling flexible in Labotronics ICP-MS spectrometers?
Yes, Labotronics ICP-MS spectrometers support stable calibration and flexible sampling modes, making them adaptable to various laboratory workflows.
5. Are Labotronics ICP-MS spectrometers suitable for nuclear and environmental testing?
Yes, Labotronics ICP-MS spectrometers are ideal for nuclear monitoring, environmental testing, and advanced material science research requiring ultra-trace accuracy.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026