Portable Multi-Gas Analyzer LB-32MA

Portable Multi-Gas Analyzer LB-32MA

Portable Multi-Gas Analyzer LB-32MA is a compact handheld analyzer, capable of measuring the concentration of multiple gases. With its built-in pump and 500ml/min flow rate, it makes extended-distance sampling easy and efficient. It features a high-definition color screen that displays real-time concentration, alarms, time, temperature, humidity, and more. Our analyzer is improved with an intrinsically safe circuit, anti-static, and anti-electromagnetic interference.

$ 4625

Download Catalog

Specifications

Sample Temperature - 40 ℃ to +70 ℃
Working Temperature - 40℃ to +120℃
Relative Humidity 0 to 100% RH
Accuracy 3 % RH
Resolution O 2 : 0.01% VOL
CO 2 : 0.01% VOL
CO : 1 PPM (0.01% VOL)
Detection Accuracy ≤ ± 3% F. S
Linearity ≤ ± 2 %
Repeatability ≤ ± 2%
Detection Principle CO 2 : Infrared principles
O 2 , CO : Electrochemical principles
Scope Of Detection O 2 : 0 -100 % VOL
CO 2 : 0 -100 % VOL
CO : 0 to 50000 PPM (0 to 5% VOL)
Flow Rate 500 ml/min
Sensor Life 2-3 years
Sampling Method Built-in pump
Response Time ≤ 20 S
Recovery Time ≤ 30 S
Display 2.31-inch 320X240 high-definition color screen display, 5-button operations
Alarm Sound and light alarm, vibration alarm, visual alarm, sound and light + vibration + visual alarm, shut off alarm
Data Storage 100,000 data capacity
Interface USB
Explosion-Proof Type Intrinsic safe
Explosion-Proof Mark EXDⅡCT6
Protection IP65, dust and splash proof
Power Supply DC 3.6 V
Battery 3.6 V DC, 4500 mA, 3.6 V DC, 4500 mA large-capacity rechargeable polymer battery, with overcharge, over-discharge, over-voltage, overheating, and short
Dimensions (L × W × H) 195 × 77 × 46 mm
Packaging Dimension 500 × 400 × 200 mm
Net Weight 400 g
Gross Weight 4 kg

Features

  • Extensive data storage capacity for comprehensive information logging
  • Allows for both partial and complete data recovery, mitigating concerns arising from misoperations
  • Prevents calibration errors caused by human factors, ensuring accurate measurements
  • Operates seamlessly across a broad range from - 40 to + 70℃
  • Displays gas concentration trends over time for easy analysis
  • Simultaneously identifies 1 to 4 gases with the flexibility of unit switching
  • Multi-level calibration ensures linearity and accuracy of measurement

Standard Accessories

Accessories no.NameQuantity
1USB charger (including data cable) 
2Aluminum alloy box 
3Alligator clip 
4Host computer communication software 
5Humidity dust filter1

Optional Accessories

1.2-meter sampling probe, Filtering high-temperature sampling and cooling handle

Applications

Ideal for use in petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, air treatment.

Get Quote

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Multi-Gas Analyzer

Multi-Gas Analyzer LB-31MA

Gas detection H2S, CO, O2, SO2, CO2, CL2, NH3, NO2, O3, HCN, VOCs, LEL
Detection Principle Electrochemistry: H2S, CO, O2, SO2, CL2, NH3, NO2, O3, HCN
Infrared ray: CO2
PID: VOCs
Catalytic: LEL
Measuring range H2S: 0 to 100 ppm
CO: 0 to 1000 ppm
O2: 0 to 30% VOL
SO2: 0 to 50 ppm
CO2: 0 to 5000 ppm
CL2: 0 to 10 ppm
NH3: 0 to 100 ppm
NO2: 0 to 50 ppm
O3: 0 to 10 ppm
HCN: 0 to 10 ppm
VOCs: 0 to 100 ppm
LEL:0 to 100% LEL
Resolution CO2, CO: 1 Ppm
O2: 0.01% VOL
LEL: 1% LEL H2S, SO2, CL2, NH3, NO2, O3, HCN, VOCs: 0.1 ppm
Precision ≤±2%F.S

$ 11375

Multi-Gas Analyzer LB-30MA

Gas detection THC, CO2, CO, NOX, SO2
Sensors Electrochemistry: CO,NOX,SO2
Infrared Ray: CO2
PID: THC
Measuring range THC: 0 to 10000 ppm
CO2: 0 to 20% VOL
CO: 0 to 10% VOL
NOX: 0 to 5000 ppm
SO2: 0 to 5000ppm
Resolution THC,NOX,SO2: 1 ppm
CO2,CO: 0.01% VOL
Precision ≤ ±2% F.S

$ 8375

Multi-gas Analyzer LB-27MA
Sensor High sensitivity sensor
Sampling method Diffusion
Detection range H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles
Operating humidity ( non-condensing ) 15 % to 90 % RH
Operating temperature ( -10 °C to 40 °C )

$ 3387.5

Multi-gas Analyzer LB-25MA
Sensor High sensitivity sensor
Sampling method Diffusion
Detection range H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles
Operating humidity ( non-condensing ) 15 % to 90 % RH
Operating temperature ( -10 °C to 40 °C )

$ 1712.5

Multi-gas Analyzer LB-24MA

Sensor High sensitivity sensor
Sampling method Pump aspiration
Detection range H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles
Operating humidity ( non-condensing ) 15 % to 90 % RH
Operating temperature ( -10 °C to 40 °C )

$ 1825

Multi-gas Analyzer LB-26MA

Sensor High sensitivity sensor
Sampling method Pump aspiration
Detection range H2S, CO, O2,SO2, CO2,Cl2, NH3, O3, HCN, PID (VOCs) and combustibles
Operating humidity ( non-condensing ) 15 % to 90 % RH
Operating temperature ( -10 °C to 40 °C )

$ 3487.5

0
×