Labotronics Portable Turbidity Meter is a compact and versatile device used for on-site measurement of water clarity by assessing the amount of suspended particles or turbidity in a liquid sample. Equipped with an optical sensor, these meters offer quick and accurate readings, making them ideal for fieldwork, environmental monitoring, and water quality assessments. The portable design, user-friendly interface, and digital display contribute to their ease of use in various settings. Our portable turbidity meters play a crucial role in ensuring compliance with water quality standards, evaluating the effectiveness of water treatment processes, and monitoring changes in environmental conditions where precise turbidity measurements are essential.
Measurement range |
0 ~ 100
0 ~ 200 |
Calibration point |
4 |
Minimum value |
0.01
0.1 |
Repeatability |
≤ 0.5 % |
Measurement range |
0 ~ 100
100 ~ 400 |
Calibration point |
5 |
Minimum value |
0.01
0.1 |
Repeatability |
≤ 0.5 % |
Measurement range |
0 ~ 100
100 ~ 500 |
Calibration point |
6 |
Minimum value |
0.01
0.1 |
Repeatability |
≤ 0.5 % |
Measurement range |
0 ~ 20 |
Calibration point |
|
Minimum value |
0.01 |
Repeatability |
≤ 1 % |
Labotronics Benchtop Turbidity Meter is a laboratory instrument designed to measure the cloudiness or turbidity of a liquid sample. Typically used in environmental monitoring, water treatment plants, and research laboratories, these meters utilize optical sensors to quantify the amount of suspended particles or colloids in the liquid. The benchtop design ensures stability during measurements, and the meters often feature a digital display for convenient and accurate readings. Our benchtop turbidity meter is an essential tool for researchers and professionals working in fields where precise turbidity measurements are necessary for quality control and compliance with regulatory standards.
Measurement range |
0 ~ 100
100 ~ 200 |
Minimum value |
0.01
0.1 |
Error |
± 6 % ( ± 2 % F.S ) |
Repeatability |
≤ 0.8 % |
Measurement range |
0 ~ 800 |
Minimum value |
0.1 |
Error |
± 6 % ( ± 2 % F.S ) |
Repeatability |
≤ 0.8 % |
Measurement range |
0 ~ 100
100 ~ 400 |
Minimum value |
0.01
0.1 |
Error |
± 6 % ( ± 2 % F.S ) |
Repeatability |
≤ 0.8 % |
Measurement range |
0 ~ 200 |
Minimum value |
0.1 |
Error |
± 6 % ( ± 2 % F.S ) |
Repeatability |
≤ 0.8 % |
Our handheld salinity meters are portable devices designed for on-the-spot measurement of salinity levels in liquids, particularly in aquatic environments. These compact instruments typically use conductivity or refractometry principles to assess the concentration of dissolved salts in water. Featuring a user-friendly interface and a digital display, handheld salinity meters provide quick and accurate readings, making them invaluable tools for fieldwork, aquaculture, and environmental monitoring. The meters often offer versatility by allowing users to switch between practical salinity units and other measurement units. With their portability and ease of use, handheld salinity meters contribute to efficient water quality assessment in diverse applications, ensuring the optimal conditions for aquatic ecosystems, research, and industrial processes.
Measurement range |
0 ~ 2500 mg/L |
Temperature |
0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) |
± 2 mg/L |
Resolution |
1 mg/L |
Measurement range |
0 ~ 9999 mg/L |
Temperature |
0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) |
± 2 mg/L |
Resolution |
1 mg/L |
Measurement range |
0 ~ 300 % |
Temperature |
0 °C ~ 50 °C |
Accuracy ( at 0.1 °C ) |
± 0.2 % |
Resolution |
0.02 |
Our Pocket TDS (Total Dissolved Solids) Meters are compact handheld devices designed for quick and convenient measurement of the concentration of dissolved solids in water. These meters typically use conductivity measurements to estimate TDS levels, providing users with valuable insights into water quality. With their portable design, digital displays, and straightforward operation, pocket TDS meters are widely used in applications such as water testing, aquarium maintenance, and hydroponics. They offer a practical and efficient way to assess the mineral content of water, ensuring its suitability for various purposes and providing essential information for maintaining optimal conditions in diverse environments.
TDS measuring range |
0 ~ 2500 ppm |
EC measuring range |
|
Temperature range |
0 °C ~ 50 °C |
Resolution |
2 ppm |
TDS measuring range |
0 ~ 9999 ppm |
EC measuring range |
|
Temperature range |
0 °C ~ 50 °C |
Resolution |
10 ppm |
TDS measuring range |
0 ~ 5000 ppm |
EC measuring range |
0 ~ 999 µs/cm |
Temperature range |
0.1 °C ~ 80 °C |
Resolution |
|
Our COD (Chemical Oxygen Demand) Thermoreactors are specialized devices used in environmental laboratories for the digestion and determination of COD levels in water samples. These reactors employ controlled heating to accelerate the chemical oxidation process, ensuring efficient breakdown of organic and inorganic compounds in the sample. Typically featuring user-friendly controls and safety features, these reactors play a key role in environmental monitoring, wastewater treatment, and compliance testing, helping industries and regulatory bodies assess the impact of pollutants on water bodies and ensure adherence to environmental standards
Number of sample |
20 (Ø 42 mm) |
Dimensions |
420 × 750 × 480 mm |
Power |
2000 W |
Temperature |
5 °C to 200 °C |
Number of sample |
12 (Ø 42 mm) |
Dimensions |
360 × 750 × 430 mm |
Power |
1500 W |
Temperature |
5 °C to 200 °C |
Number of sample |
8 (Ø 42 mm) |
Dimensions |
350 × 750 × 370 mm |
Power |
1000 W |
Temperature |
5 °C to 200 °C |