Real time PCR LB-11RTPCR is a microprocessor controlled dual channeled unit. It is characterized with a photomultiplier tube as a detector for amplification. Quantitative estimation of targeted DNA molecule is carried out during conventional PCR.
Buy Now Download CatalogSpecifications
Sample capacity | 48 well positions |
Testing range | 101 DNA/RNA copy/mL ~ 1010 DNA/RNA copy/mL |
Temperature range | 4 °C ~ 99 °C |
Heating rate | 3 °C / sec |
Cooling rate | 2 °C / sec |
Profiles | 1 ~ 9 |
Cycles | 1 ~ 99 |
Hold time | 1 sec ~ 9999 sec |
Excitation wavelength | Channel 1: 470 nm ~ 505 nm Channel 2: 525 nm ~ 545 nm |
Emission wavelength | Channel 1: 523 nm ~ 543 nm Channel 2: 550 nm ~ 615 nm |
Consumables | Thick walled 0.2 mL PCR tubes 8-strip tubes |
Reaction volume | 10 µL ~ 100 µL |
Correlation coefficient of nucleic acid precision | R ≥ 0.0997 |
Reproducibility | CV ≤ 2.1 % |
Temperature accuracy | ± 0.1 °C |
Temperature uniformity | ± 0.3 °C |
Ambient temperature | 5 °C ~ 40 °C |
Relative humidity | ≤ 80 % |
Dimensions | 550 × 420 × 350 mm |
Weight | 27 kgs |
Features
Applications
Used for quantitative and semi quantitative analysis for real time PCR in diagnosis of clinical diseases, animal diseases, food safety, research purpose, etc.
What our customers say
Sajjad Hussain
10 months ago
Abel Bereket
1 year ago
Areesha Arshad
3 years ago
Areesha Arshad
1 year ago
Hunegnaw Guday
2 years ago
Suman .
3 years ago
Khurram Ahmed
1 year ago
Yibeltal yihunie
1 year ago
Aregawi Gebre
2 years ago
Zaid Hazim Kamal
2 years ago
Deepak Pillai
1 year ago
Kaiser Arshad
2 years ago
Caleb Otieno Ochola
1 year ago
Eng Faisal Khan
2 years ago
Mohammed Kaif
1 year ago
Eng. Ghassan A. Bishara
1 year ago
Jatindra Nath Paul
2 years ago
Ashenif Adamu
2 years ago
Mae .
2 years ago
Abhishek Srivastava
1 year ago
Robert K. Ngeno
8 months ago
Mohamed Suleiman
2 years ago
Anowar Hossain
2 years ago
Ekrima Yahya Abu Arra
1 year ago
Sir
4 months ago
Ivelina Sofronieva
2 years ago
Esther Kabui
8 months ago
Ikram .
3 years ago
Onyishi Chioma
1 year ago
Jannatul Ferdousi Sonia
1 year ago
Laith Assaleem
3 years ago
Tarakeswar Nath
1 year ago
Tagume Hosea
6 months ago
Ayman .
1 year ago
Sharjeel .
3 months ago
Maram Aldarwish
1 year ago
Ekram Mahmoud
1 year ago
Bekele Haile
1 year ago
Kadar Basha
3 years ago
Mary
2 years ago
Humayun Iqbal
4 weeks ago
Jeadelyn .
9 months ago
Amer .
2 years ago
Altaf Lodhi
3 years ago
KENNEDY OERI
1 year ago
Add a review
Sample capacity | 96 well positions |
Channels | 5 |
Testing range | 10^2 to 10^10 |
Sensitivity | Down to 1 copy |
Categories
Best Seller