$ 1987.5
Download CatalogSpecifications
| Temperature Setting Range | 0°C to 100°C |
| Temperature Control Range | RT.-20°C to 100°C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Uniformity | ≤ ± 0.3°C |
| Shaking Speed | 200 to 1500 rpm |
| Timing Range | 1 minute to 99 hours 59 minutes or continuous (∞) |
| Display Accuracy | 0.1°C |
| Heating Time | ≤ 15 minutes (from 25°C to 100°C) |
| Multi-point Running | Up to 5 points |
| Multi-cycle | Up to 99 cycles |
| Orbit | 3 mm |
| Cooling Time 1 | ≤ 10 minutes (from 100°C to 25°C) |
| Cooling Time 2 | ≤ 15 minutes (from RT to RT -20°C) |
| Storage Temperature | 4°C |
| Auto Heating | Yes |
| Auto Running | Yes |
| Auto Resume to Run | Yes |
| Fuse | 250V, 3A, Ф5 × 20 mm |
| Power Consumption | 150W |
| Power Supply | AC 110V-220V, 50-60Hz |
| Dimensions | 260 × 195 × 150 mm |
| Weight | 7.5 kg |
Features
Optional Accessories
| Block Type | Capacity | Speed Range |
| Block 0.2 mL | 96 | 200 to 1500 rpm |
| Block 0.5 mL | 54 | 200 to 1500 rpm |
| Block 1.5 mL | 35 | 200 to 1500 rpm |
| Block 2.0 mL | 35 | 200 to 1500 rpm |
| Block 0.5 mL + 1.5 mL | 15+20 | 200 to 1800 rpm |
| Block 0.2 mL (Elisa plate) | 96 | 200 to 1500 rpm |
| Block 5 mL | 24 | 200 to 1000 rpm |
| Block 10 mL | 15 | 200 to 1000 rpm |
| Block 15 mL | 12 | 200 to 800 rpm |
| Block Round 50 mL | 6 | 200 to 800 rpm |
| Block Conical 50 mL | 6 | 200 to 800 rpm |
Applications
Thermo Shaker Incubator LB-10TSI is used for enzyme reactions, PCR sample preparation, and sample storage in molecular biology, chemistry, and biochemistry laboratories.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Temperature Setting Range | 0°C to 100°C |
| Temperature Control Range | RT+5°C to 100°C |
| Temperature Accuracy | ≤ ± 0.2°C (at 37°C) |
| Temperature Uniformity | ≤ ± 0.2°C (at 37°C) |
| Shaking Speed | 200 to 2000 rpm |
| Temperature Setting Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Uniformity | ≤ ± 0.3°C |
| Shaking Speed | 200 to 1800 rpm |
| Temperature Setting Range | 0°C to 100°C |
| Temperature Control Range | RT -20°C to 100°C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Uniformity | ≤ ± 0.3°C |
| Shaking Speed | 200 to 1500 rpm |
| Temperature Setting Range | 0°C to 100°C |
| Temperature Control Range | RT +5°C to 100°C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Uniformity | ≤ ± 0.3°C |
| Shaking Speed | 200 to 3000 rpm |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534