Benchtop Turbidity Meter LB-15BTM

Benchtop Turbidity Meter LB-15BTM

Benchtop turbidity meter LB-15BTM is a microprocessor controlled unit with a semi-automatic calibration. LED screen displays real time data. Automatic power off post thirty minutes of non-use prolongs battery life. It measures the turbidity of water and quantitatively analyzes the insoluble particulate matter.

Buy Now Download Catalog

Specifications

Measurement range 0 ~ 100
100 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Drift ± 0.8 % F.S
Battery power 1.5 V × 5 AAA
Power supply AC 220 V/50 Hz
DC 7.5 V/0.2 A
Dimensions 400 × 300 × 250 mm

Features

  • LED screen displays measurements and results
  • Test data storage ( 10 groups )
  • Dust and waterproof structure
  • Semi-automatic calibration
  • Auto power off ( after 30 minutes )

Applications

Used in wastewater treatments, laboratories, aquaculture, agriculture, research institutes, food and beverage industry, etc.

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Add a review

Benchtop Turbidity Meter

Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-11BTM
Measurement range 0 ~ 100
100 ~ 200
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-16BTM
Measurement range 0 ~ 1000
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-13BTM
Measurement range 0 ~ 100
100 ~ 400
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-10BTM
Measurement range 0 ~ 200
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-12BTM
Measurement range 0 ~ 400
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-17BTM
Type Benchtop
Principle method Nephelometric principle with 90° detection
Measuring Range 0 to 20, 20 to 200, and 200 to 1000 NTU
Auto-ranging 0 to 1000 NTUs
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-14BTM
Measurement range 0 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %

Our ORP (Oxidation-Reduction Potential) Pocket Meters are compact, handheld devices designed for convenient on-the-go measurement of the oxidative or reducing ability of a solution. Utilizing an electrode system, these meters assess the electron activity in the liquid, providing a quick indication of its redox potential. Commonly used in water quality testing, aquaculture, and industrial processes, ORP pocket meters are valuable tools for assessing the overall health and stability of a solution. With a portable design, digital display, and user-friendly controls, these meters offer flexibility in monitoring and optimizing oxidative/reductive conditions in various settings, contributing to the efficient management of water quality, chemical processes, and environmental conditions.

Measuring range -1200 mV ~ 1200 mV
Accuracy ± 2 mV
Temperature 0 °C ~ 50 °C
Resolution 1 mV
Measuring range ± 1999 mV
Accuracy ± 5 mV
Temperature 0 °C ~ 50 °C
Resolution

Our handheld salinity meters are portable devices designed for on-the-spot measurement of salinity levels in liquids, particularly in aquatic environments. These compact instruments typically use conductivity or refractometry principles to assess the concentration of dissolved salts in water. Featuring a user-friendly interface and a digital display, handheld salinity meters provide quick and accurate readings, making them invaluable tools for fieldwork, aquaculture, and environmental monitoring. The meters often offer versatility by allowing users to switch between practical salinity units and other measurement units. With their portability and ease of use, handheld salinity meters contribute to efficient water quality assessment in diverse applications, ensuring the optimal conditions for aquatic ecosystems, research, and industrial processes.

Measurement range 0 ~ 9999 mg/L
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 2 mg/L
Resolution 1 mg/L
Measurement range 0 ~ 2500 mg/L
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 2 mg/L
Resolution 1 mg/L
Measurement range 0 ~ 300 %
Temperature 0 °C ~ 50 °C
Accuracy ( at 0.1 °C ) ± 0.2 %
Resolution 0.02

Our Benchtop Conductivity Meter is a compact and precision instrument used for measuring the electrical conductivity of liquids. Typically designed for laboratory or industrial settings, it consists of a control unit and a conductivity cell. The meter assesses the ability of a solution to conduct an electric current, providing valuable information about the solution's ionic content and purity. Our benchtop models offer accuracy and ease of use, often featuring digital displays, adjustable settings, and the capacity to measure a wide range of conductivity levels. Widely utilized in chemistry, environmental science, and quality control applications, these meters play a crucial role in ensuring the consistency and reliability of solutions in diverse industries.

Measuring range Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω.cm to 100.00 MΩ.cm TDS: 0.000 to 1000 ppt Salinity: 0.00 to 8.00% Temperature: -10 to 135°C; 14 to 275°F
Resolution Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω.cm TDS: 0.001 ppm Salinity: 0.01% Temperature: 0.1°C/°F
Accuracy Conductivity: ±0.5% FS Resistivity: ±0.5% FS TDS: ±0.5% FS Salinity: ±0.01% Temperature: ±0.1°C/°F
Conductivity calibration points Up to 5
Measurement range 0.0 ~ 199.9 µs/cm 200 µs/cm ~ 1999 µs/cm 2.0 µs/cm ~ 19.99 ms/cm 20 µs/cm ~ 199.9 ms/cm
Temperature compensation 10 °C ~ 50 °C ( manual )
Resolution 0.1/1µs/cm 0.01/0.1ms/cm
Accuracy ( electrode ) ± 1 % FS
Measuring range Conductivity: 0.00 µS/cm to 200 mS/cm TDS: 0.00 mg/L to 100 g/L
Resolution Conductivity: 0.01 µS/cm TDS: 0.01 mg/L
Accuracy ±1.0% FS
Conductivity reference temperature 25°C
Measurement range 0.0 ~ 2 × 105 µs/cm
Temperature compensation 15 °C ~ 35 °C ( manual )
Resolution
Accuracy ( electrode ) ± 1 % FS

We provide a benchtop multiparameter meter is a versatile laboratory instrument designed to concurrently measure and display various physicochemical parameters in liquids. This compact device typically integrates probes for parameters such as pH, conductivity, dissolved oxygen, and temperature, providing a comprehensive analysis of liquid samples. Equipped with a user-friendly interface and a digital display, these meters offer efficient and precise data collection for research, quality control, and environmental monitoring purposes. Their benchtop design ensures stability and ease of use in laboratory settings, allowing scientists and researchers to streamline the measurement process and obtain valuable information about the composition and quality of liquids.

COD Measuring Range 10 to 15000 mg/L
COD Detection Method Potassium Dichromate Method Potassium Permanganate method
COD Detection Lower Limit 10 mg/L
COD Digestion Temperature & Time 165 °C, 20 min
Temperature Parameters Range: -5 to 110 ºC, 23 to 230 ºF Unit: ºC, ºF Resolution: 0.1 Accuracy: ±0.2
Measurement Modes Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous Reading Prompts: Reading, Stable, Locked, Temp. Compensation: ATC, MTC
Parameters pH/ EC/ ISE/ Temp. (mV/ ORP/ pX/ Resistivity/ TDS /Sal.)
pH Range: -2.00 to 20.00 ph Resolution: 0.1, 0.01 pH Accuracy: ±0.01 pH Calibration Points: Up to 5 Standard Recognition: NIST, GB, and DIN buffers Slope Limit
Measuring parameters pH/EC/ISE/Temperature (mV/ORP/pX/Resistivity/TDS/Salinity)
Measuring range pH: -2.000 to 20.000 pH mV/ORP: -2000.00 to 2000.00 mV pX range: -2.000 to 20.000 pX ISE: 1E-9 to 9.999E9 Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω·cm to 100.00 MΩ·cm TDS: 0.000 to 1000 ppt Salinity: 0.0 to 80.0 ppt Temperature: -10 to 135°C, 14 to 275°F
Resolution pH: 0.1, 0.01, 0.001 pH mV/ORP: 0.1, 0.01 mV pX: 0.1, 0.01, 0.001 pX ISE: Up to 4 significant units Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω·cm TDS: 0.001 ppm Salinity: 0.1 ppt Temperature: 0.1°C/°F
Accuracy pH: ±0.002 pH mV/ORP: ±0.1 mV or ±0.03% pX: ±0.002 pX ISE: ±0.3% Conductivity: ±0.5%FS Resistivity: ±0.5% FS TDS: ±0.5% Salinity: ±1 ppt Temperature: ±0.1 °C/°F

Our Pocket TDS (Total Dissolved Solids) Meters are compact handheld devices designed for quick and convenient measurement of the concentration of dissolved solids in water. These meters typically use conductivity measurements to estimate TDS levels, providing users with valuable insights into water quality. With their portable design, digital displays, and straightforward operation, pocket TDS meters are widely used in applications such as water testing, aquarium maintenance, and hydroponics. They offer a practical and efficient way to assess the mineral content of water, ensuring its suitability for various purposes and providing essential information for maintaining optimal conditions in diverse environments.

TDS measuring range 0 ~ 2500 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 2 ppm
TDS measuring range 0 ~ 9999 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 10 ppm
TDS measuring range 0 ~ 5000 ppm
EC measuring range 0 ~ 999 µs/cm
Temperature range 0.1 °C ~ 80 °C
Resolution
WhatsApp
×

Get Quotation

Follow Us

Copyright © Labotronics Scientific 2024