Benchtop Turbidity Meter LB-17BTM

Benchtop Turbidity Meter LB-17BTM

Benchtop Turbidity Meter LB-17BTM is a benchtop type microprocessor controlled unit for precision turbidity measurement, employs Nephelometric principle with 90° detection. Offers ≤±6% accuracy and ≤0.5% repeatability. Features customizable NTU, FNU, and EBC turbidity units, 0-1000 NTUs auto-ranging capacity, and 1 to 7 calibration points. Designed with an 880nm LED light source and programmable parameters such as user ID, number of calibration points, data and time, etc., has data storage capacity of 2000 sets and USB or RS-232 interface for easy data processing.

Buy Now Download Catalog

Specifications

Type Benchtop
Principle method Nephelometric principle with 90° detection
Measuring Range 0 to 20, 20 to 200, and 200 to 1000 NTU
Auto-ranging 0 to 1000 NTUs
Accuracy ≤±6%
Repeatability ≤0.5%
Fluctuation ≤±0.5% FS/30 min
Calibration Points 1 to 7
Light Source 880nm LED
Units Selectable NTU, FNU and EBC turbidity unit
Data capacity Up to 2000 sets (GLP-compliant)
Interface USB or RS-232
Power Supply AC Adapter, 200 to 240 VAC input
Dimension (L×W×H) 330×250×130 mm
Weight 2.5 kg

Features

  • Benchtop type microprocessor controlled unit for precision turbidity measurement
  • Nephelometric measurement principle comprised turbidity meter with 90° detection
  • Accuracy of ≤±6% and ≤0.5% repeatability, ensure ideal results
  • Advanced configuration and powerful functioning based on an Infrared light source
  • Customizable turbidity units include NTU, FNU, and EBC
  • Measuring range of 0 to 20, 20 to 200, and 200 to 1000 NTU with auto-ranging capability
  • 880nm LED light source, reliable and user-friendly operation
  • Programmable parameters such as user ID, number of calibration points, data and time, etc.
  • 1 to 7 Calibration Points using formazin standards or zero water
  • Data storage capacity up to 2000 sets (GLP- compliant)
  • USB or RS-232 interface for easy data processing

Our Team Of Experts Will Promptly Address Your Inquiry.

What our customers say

Norman Vella logo

9 months ago

Muhammad Arif logo

2 years ago

Saurabh Meghare logo

2 years ago

Abdur Rehman logo

1 month ago

Engr. Danish logo

1 year ago

Bekele Haile logo

1 year ago

Saini . logo

1 month ago

Serenay Dicle logo

2 years ago

Kashyap Nagariya logo

8 months ago

Deepak Chawla logo

1 year ago

Hunegnaw Guday logo

1 year ago

Mae . logo

1 year ago

Jagath Siriwardana logo

1 year ago

Mohannad Khaleel logo

8 months ago

SACHINI SAMUDIKA logo

2 years ago

Tarek Hadad logo

1 week ago

Nicola Heredia logo

1 year ago

Maniram Pathak logo

1 year ago

Aregawi Gebre logo

1 year ago

Mohannad Abu Rub logo

3 months ago

Jenan Naem Bouzia logo

5 months ago

Adel Qatanani logo

1 year ago

Claude NDAHIMAMA logo

2 months ago

Altaf Lodhi logo

2 years ago

Eng.Enas Jayyousi logo

2 years ago

S. Kavidhas logo

2 years ago

Eng. Ghassan A. Bishara logo

1 year ago

Sharjeel . logo

3 weeks ago

SrinivasaRao J logo

3 days ago

Gabi Odeh logo

9 months ago

Kadar Basha logo

2 years ago

SAMUEL AMPOMAH logo

1 year ago

Kuldeep malagi logo

2 years ago

Muhammad Ali logo

1 year ago

Add a review

Benchtop Turbidity Meter

Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-10BTM
Measurement range 0 ~ 200
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-13BTM
Measurement range 0 ~ 100
100 ~ 400
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-11BTM
Measurement range 0 ~ 100
100 ~ 200
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-16BTM
Measurement range 0 ~ 1000
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-12BTM
Measurement range 0 ~ 400
Minimum value 0.01
0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-15BTM
Measurement range 0 ~ 100
100 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %
Benchtop Turbidity Meter : Benchtop Turbidity Meter LB-14BTM
Measurement range 0 ~ 800
Minimum value 0.1
Error ± 6 % ( ± 2 % F.S )
Repeatability ≤ 0.8 %

Our Benchtop Conductivity Meter is a compact and precision instrument used for measuring the electrical conductivity of liquids. Typically designed for laboratory or industrial settings, it consists of a control unit and a conductivity cell. The meter assesses the ability of a solution to conduct an electric current, providing valuable information about the solution's ionic content and purity. Our benchtop models offer accuracy and ease of use, often featuring digital displays, adjustable settings, and the capacity to measure a wide range of conductivity levels. Widely utilized in chemistry, environmental science, and quality control applications, these meters play a crucial role in ensuring the consistency and reliability of solutions in diverse industries.

Measuring range Conductivity: 0.00 µS/cm to 200 mS/cm TDS: 0.00 mg/L to 100 g/L
Resolution Conductivity: 0.01 µS/cm TDS: 0.01 mg/L
Accuracy ±1.0% FS
Conductivity reference temperature 25°C
Measurement range 0.0 ~ 199.9 µs/cm 200 µs/cm ~ 1999 µs/cm 2.0 µs/cm ~ 19.99 ms/cm 20 µs/cm ~ 199.9 ms/cm
Temperature compensation 10 °C ~ 50 °C ( manual )
Resolution 0.1/1µs/cm 0.01/0.1ms/cm
Accuracy ( electrode ) ± 1 % FS
Measuring range Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω.cm to 100.00 MΩ.cm TDS: 0.000 to 1000 ppt Salinity: 0.00 to 8.00% Temperature: -10 to 135°C; 14 to 275°F
Resolution Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω.cm TDS: 0.001 ppm Salinity: 0.01% Temperature: 0.1°C/°F
Accuracy Conductivity: ±0.5% FS Resistivity: ±0.5% FS TDS: ±0.5% FS Salinity: ±0.01% Temperature: ±0.1°C/°F
Conductivity calibration points Up to 5
Measurement range 0.0 ~ 2 × 105 µs/cm
Temperature compensation 15 °C ~ 35 °C ( manual )
Resolution
Accuracy ( electrode ) ± 1 % FS

Our Pocket TDS (Total Dissolved Solids) Meters are compact handheld devices designed for quick and convenient measurement of the concentration of dissolved solids in water. These meters typically use conductivity measurements to estimate TDS levels, providing users with valuable insights into water quality. With their portable design, digital displays, and straightforward operation, pocket TDS meters are widely used in applications such as water testing, aquarium maintenance, and hydroponics. They offer a practical and efficient way to assess the mineral content of water, ensuring its suitability for various purposes and providing essential information for maintaining optimal conditions in diverse environments.

TDS measuring range 0 ~ 9999 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 10 ppm
TDS measuring range 0 ~ 2500 ppm
EC measuring range
Temperature range 0 °C ~ 50 °C
Resolution 2 ppm
TDS measuring range 0 ~ 5000 ppm
EC measuring range 0 ~ 999 µs/cm
Temperature range 0.1 °C ~ 80 °C
Resolution

Our ORP (Oxidation-Reduction Potential) Pocket Meters are compact, handheld devices designed for convenient on-the-go measurement of the oxidative or reducing ability of a solution. Utilizing an electrode system, these meters assess the electron activity in the liquid, providing a quick indication of its redox potential. Commonly used in water quality testing, aquaculture, and industrial processes, ORP pocket meters are valuable tools for assessing the overall health and stability of a solution. With a portable design, digital display, and user-friendly controls, these meters offer flexibility in monitoring and optimizing oxidative/reductive conditions in various settings, contributing to the efficient management of water quality, chemical processes, and environmental conditions.

Measuring range ± 1999 mV
Accuracy ± 5 mV
Temperature 0 °C ~ 50 °C
Resolution
Measuring range -1200 mV ~ 1200 mV
Accuracy ± 2 mV
Temperature 0 °C ~ 50 °C
Resolution 1 mV

Our COD (Chemical Oxygen Demand) Thermoreactors are specialized devices used in environmental laboratories for the digestion and determination of COD levels in water samples. These reactors employ controlled heating to accelerate the chemical oxidation process, ensuring efficient breakdown of organic and inorganic compounds in the sample. Typically featuring user-friendly controls and safety features, these reactors play a key role in environmental monitoring, wastewater treatment, and compliance testing, helping industries and regulatory bodies assess the impact of pollutants on water bodies and ensure adherence to environmental standards

Number of sample 12 (Ø 42 mm)
Dimensions 360 × 750 × 430 mm
Power 1500 W
Temperature 5 °C to 200 °C
Number of sample 20 (Ø 42 mm)
Dimensions 420 × 750 × 480 mm
Power 2000 W
Temperature 5 °C to 200 °C
Number of sample 8 (Ø 42 mm)
Dimensions 350 × 750 × 370 mm
Power 1000 W
Temperature 5 °C to 200 °C

Labotronics Ratio Turbidimeter is an analytical instrument specifically designed for measuring the turbidity of liquid samples by employing a ratio turbidimetry technique. This method involves the measurement of scattered light at two different angles, typically 90 and 180 degrees, to enhance accuracy in turbidity readings. The instrument uses a dual detector system to minimize interferences and improve sensitivity, ensuring precise and reliable turbidity measurements. Our ratio turbidimeters are commonly employed in water treatment facilities, environmental monitoring, and industrial processes where accurate turbidity assessments are crucial for quality control and regulatory compliance.

Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU 2001~4000 NTU
Allowable error of indication ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU
Allowable error of indication ≤ ± 8 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
Measurement range 0.005 ~ 50.0 NTU 1 ~ 200 NTU 201 ~2000 NTU
Allowable error of indication 0 ~ 200 NTU: ≤ ± 8 % 201 ~ 200 NTU: ≤ ± 6 %
Receiving element Silicon photocell
Light source Tungsten halogen lamp 6 V, 10 W
WhatsApp
×

Get Quotation