Flame Spectrophotometer LB-15FSP

Flame Spectrophotometer LB-15FSP

Flame Spectrophotometer LB-15FSP is an analytical instrument with pre-selection flame sizes for elemental detection. Liquefied petroleum gas is consumed for burning of the flame to produce luminescence. It is equipped with a flame protection for safety of the operator.

$ 3300

Download Catalog

Specifications

Elements detected K, Na, Ba
Sensitivity K- 0.01 ppm
Na- 0.01 ppm
Ba- 6 ppm
Range K- 0 ppm ~ 100 ppm
Na- 0 ppm ~ 160 ppm
Ba- 0 ppm ~ 3000 ppm
Method detection limit K- ≤0.156 ppm
Na- ≤0.184 ppm
Ba- ≤60.28 ppm
Linearity K- 0.195 ppm (0.39 ppm ~ 3.12 ppm)
Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm )
Ba- 9 ppm
Linearity error K- ≤0.195 ppm
Na- ≤0.69 ppm
Ba- ≤9.042 ppm
Sample uptake < 6 mL/min
Repeatability 1% CV for 20 consecutive samples
Response time < 8s
Ambient temperature 10 °C ~ 35 °C
Humidity ≤ 85%
Power supply AC 110 V ±10%; 50 Hz
AC 220 V ±10%; 60 Hz
Power consumption 250 W
Dimensions 580 × 540 × 400 mm
Weight 18 kgs

Features

  • Adjustable measuring range
  • Direct concentration read out
  • Large LCD touch screen display for ease of accessibility
  • Correlation coefficient with automated calculative function (Except LB-10FSP)
  • Equipped with an air compressor for stable flow rate of air during flammation
  • USB interface (Except LB-10FSP)

Standard Accessories

Sr. No.Name of the accessoryQuantity
1.Air compressor1 unit

Applications

Used in the fields agriculture, chemistry, pharmacology, pathology, biology, forensics, etc. for analysis of particular elements in the material.

Get Quote

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Flame Spectrophotometer

Flame Spectrophotometer LB-13FSP

Elements detected K, Na, Ca
Sensitivity K- 0.01 ppm
Na- 0.01 ppm
Ca- 2 ppm
Range K- 0 ppm ~ 100 ppm
Na- 0 ppm ~ 160 ppm
Ca- 0 ppm ~ 1000 ppm
Method detection limit K- ≤0.156 ppm
Na- ≤0.184 ppm
Ca- ≤2 ppm
Linearity K- 0.195 ppm (0.39 ppm ~ 3.12 ppm)
Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm )
Ca- 3 ppm (5 ppm ~ 100 ppm)

$ 4875

Flame Spectrophotometer LB-11FSP

Elements detected K, Na
Sensitivity K- 0.01 ppm
Na- 0.01 ppm
Range K- 0 ppm ~ 100 ppm
Na- 0 ppm ~ 160 ppm
Method detection limit K- ≤0.156 ppm
Na- ≤0.184 ppm
Linearity K- 0.195 ppm (0.39 ppm ~ 3.12 ppm)
Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm )

$ 3625

Flame Spectrophotometer LB-10FSP
Measuring range K: 0.195 ppm (0.39 to 3.12) ppm
Na: 0.69 ppm (1.15 to 9.2) ppm
Li: 0.15 ppm (0.25 to 5) ppm
Ca: 3 ppm (5 to 100) ppm
Ba: 9 ppm
Sensitivity K: 0.01 ppm
Na:0.01 ppm
Li: 0.1 ppm
Ca: 2 ppm
Ba: 6 ppm
Repeatability 1% CV for 20 consecutive samples
Sample uptake < 6 ml/min
Response time < 8 sec

$ 4187.5

Flame Spectrophotometer LB-12FSP
Elements detected K, Na, Li
Sensitivity K- 0.01 ppm
Na- 0.01 ppm
Li- 0.01 ppm
Range K- 0 ppm ~ 100 ppm
Na- 0 ppm ~ 160 ppm
Li- 0 ppm ~ 100 ppm
Method detection limit K- ≤0.156 ppm
Na- ≤0.184 ppm
Li- 0.105 ppm
Linearity K- 0.195 ppm (0.39 ppm ~ 3.12 ppm)
Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm)
Li- 0.15 ppm (0.25 ppm ~ 5 ppm)

$ 4125

Flame Spectrophotometer LB-14FSP

Elements detected K, Na, Li, Ca
Sensitivity K- 0.01 ppm
Na- 0.01 ppm
Li- 0.1 ppm
Ca- 2 ppm
Range K- 0 ppm ~ 100 ppm
Na- 0 ppm ~ 160 ppm
Li- 0 ppm ~ 100 ppm
Ca- 0 ppm ~ 1000 ppm
Method detection limit K- ≤0.156 ppm
Na- ≤0.184 ppm
Li- ≤0.105 ppm
Ca- ≤2 ppm
Linearity K- 0.195 ppm (0.39 ppm ~ 3.12 ppm)
Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm )
Li- 0.15 ppm (0.25 ppm ~ 5 ppm)
Ca- 3 ppm (5 ppm ~ 100 ppm)

$ 3487.5

Flame Spectrophotometer LB-16FSP

Measurement Range Potassium (K): 0 to 100 ppm
Sodium (Na): 0 to 160 ppm
Minimum Detection Limit Potassium (K): 0.1 ppm
Sodium (Na): 0.1 ppm
Linear Error Potassium (K): ± 0.2 ppm
Sodium (Na): ± 0.5 ppm
Display Range Potassium (K): 0 to 100 μg/ml
Sodium (Na): 0 to 160 μg/ml
Stability The biggest change in relative volume in 15 seconds: ≤ 3%

$ 2012.5