$ 3300
Download CatalogSpecifications
| Elements detected | K, Na, Ba |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Ba- 6 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Ba- 0 ppm ~ 3000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Ba- ≤60.28 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm ) Ba- 9 ppm |
| Linearity error | K- ≤0.195 ppm Na- ≤0.69 ppm Ba- ≤9.042 ppm |
| Sample uptake | < 6 mL/min |
| Repeatability | 1% CV for 20 consecutive samples |
| Response time | < 8s |
| Ambient temperature | 10 °C ~ 35 °C |
| Humidity | ≤ 85% |
| Power supply | AC 110 V ±10%; 50 Hz AC 220 V ±10%; 60 Hz |
| Power consumption | 250 W |
| Dimensions | 580 × 540 × 400 mm |
| Weight | 18 kgs |
Features
Standard Accessories
| Sr. No. | Name of the accessory | Quantity |
|---|---|---|
| 1. | Air compressor | 1 unit |
Applications
Used in the fields agriculture, chemistry, pharmacology, pathology, biology, forensics, etc. for analysis of particular elements in the material.Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Elements detected | K, Na, Ca |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Ca- 2 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Ca- 0 ppm ~ 1000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Ca- ≤2 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm ) Ca- 3 ppm (5 ppm ~ 100 ppm) |
| Elements detected | K, Na |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm ) |
| Measuring range | K: 0.195 ppm (0.39 to 3.12) ppm Na: 0.69 ppm (1.15 to 9.2) ppm Li: 0.15 ppm (0.25 to 5) ppm Ca: 3 ppm (5 to 100) ppm Ba: 9 ppm |
| Sensitivity | K: 0.01 ppm Na:0.01 ppm Li: 0.1 ppm Ca: 2 ppm Ba: 6 ppm |
| Repeatability | 1% CV for 20 consecutive samples |
| Sample uptake | < 6 ml/min |
| Response time | < 8 sec |
| Elements detected | K, Na, Li |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Li- 0.01 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Li- 0 ppm ~ 100 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Li- 0.105 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm) Li- 0.15 ppm (0.25 ppm ~ 5 ppm) |
| Elements detected | K, Na, Li, Ca |
| Sensitivity | K- 0.01 ppm Na- 0.01 ppm Li- 0.1 ppm Ca- 2 ppm |
| Range | K- 0 ppm ~ 100 ppm Na- 0 ppm ~ 160 ppm Li- 0 ppm ~ 100 ppm Ca- 0 ppm ~ 1000 ppm |
| Method detection limit | K- ≤0.156 ppm Na- ≤0.184 ppm Li- ≤0.105 ppm Ca- ≤2 ppm |
| Linearity | K- 0.195 ppm (0.39 ppm ~ 3.12 ppm) Na- 0.69 ppm (1.15 ppm ~ 9.2 ppm ) Li- 0.15 ppm (0.25 ppm ~ 5 ppm) Ca- 3 ppm (5 ppm ~ 100 ppm) |
| Measurement Range | Potassium (K): 0 to 100 ppm Sodium (Na): 0 to 160 ppm |
| Minimum Detection Limit | Potassium (K): 0.1 ppm Sodium (Na): 0.1 ppm |
| Linear Error | Potassium (K): ± 0.2 ppm Sodium (Na): ± 0.5 ppm |
| Display Range | Potassium (K): 0 to 100 μg/ml Sodium (Na): 0 to 160 μg/ml |
| Stability | The biggest change in relative volume in 15 seconds: ≤ 3% |