$ 10100
Download CatalogSpecifications
| Temperature range | -50 °C ~ 2250 °C -58 °F ~ 4082 °F |
| Optimal resolution | 50:1 |
| Emissivity (adjustable) | 0.10 ~ 1.0 |
| Resolution | 0.1 °C/°F |
| Accuracy | -50 °C ~ 0 °C; ± 4 °C 0 °C ~ 500 °C; ± 1.5 % or reading ± 2 °C/3.6 °F Above 500 °C; ± 2 % or reading ± 2 °C/3.6 °F |
| Response time | < 250 ms |
| Response wavelength | 8 µm ~ 14 µm |
| Operating conditions | 0 °C ~ 50 °C 32 °F ~ 122 °F < 95 % RH (non-condensation) |
| Storage conditions | -20 °C ~ 70 °C -4 °F ~ 158 °F < 80 % RH |
| Diode laser | Output < 1 mW Wavelength: 630 nm ~ 670 nm Class II |
| Dimensions | 192 x 126 x 61 mm |
| Weight | 300 g |
Features
Standard Accessories
| Sr No | Accessory |
|---|---|
| 1 | 9 V battery |
| 2 | Carrying case |
Applications
Used to measure temperature in industries, hospitals, cold storage, metallurgy, forensic science, food processing, petrochemical, railways, etc.Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Temperature range | -50 °C ~ 900 °C -58 °F ~ 1652 °F |
| Optimal resolution | 20:1 |
| Emissivity (adjustable) | 0.1 ~ 1.0 |
| Resolution | 0.1 °C / 0.1 °F ( < 1000 °C ) |
| Accuracy | ± 2 % / ± 2 °C |
| Temperature range | -50 °C ~ 1350 °C -58 °F ~ 2462 °F |
| Optimal resolution | 50:1 |
| Emissivity (adjustable) | 0.10 ~ 1.0 |
| Resolution | 0.1 °C/°F |
| Accuracy | -50 °C ~ 0 °C; ± 4 °C 0 °C ~ 500 °C; ± 1.5 % or reading ± 2 °C/3.6 °F Above 500 °C; ± 2 % or reading ± 2 °C/3.6 °F |
| Temperature range | -50 °C ~ 1850 °C -58 °F ~ 3362 °F |
| Optimal resolution | 50:1 |
| Emissivity (adjustable) | 0.10 ~ 1.0 |
| Resolution | 0.1 °C/°F |
| Accuracy | -50 °C ~ 0 °C; ± 4 °C 0 °C ~ 500 °C; ± 1.5 % or reading ± 2 °C/3.6 °F Above 500 °C; ± 2 % or reading ± 2 °C/3.6 °F |
| Temperature range | -50 °C ~ 1150 °C -58 °F ~ 2102 °F |
| Optimal resolution | 50:1 |
| Emissivity (adjustable) | 0.10 ~ 1.0 |
| Resolution | 0.1 °C/°F |
| Accuracy | -50 °C ~ 0 °C; ± 4 °C 0 °C ~ 500 °C; ± 1.5 % or reading ± 2 °C/3.6 °F Above 500 °C; ± 2 % or reading ± 2 °C/3.6 °F |
| Temperature range | -50 °C ~ 1650 °C -58 °F ~ 3002 °F |
| Optimal resolution | 50:1 |
| Emissivity (adjustable) | 0.10 ~ 1.0 |
| Resolution | 0.1 °C/°F |
| Accuracy | -50 °C ~ 0 °C; ± 4 °C 0 °C ~ 500 °C; ± 1.5 % or reading ± 2 °C/3.6 °F Above 500 °C; ± 2 % or reading ± 2 °C/3.6 °F |
| Temperature range | -50 °C ~ 1000 °C -58 °F ~ 1832 °F |
| Optimal resolution | 20:1 |
| Emissivity (adjustable) | 0.1 ~ 1.0 |
| Resolution | 0.1 °C / 0.1 °F ( < 1000 °C ) |
| Accuracy | ± 2 % / ± 2 °C |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026