Horizontal Electrophoresis Unit LB-23HEU is a high resolution horizontal system with leak proof assembly for electrophoretic procedures. Large volume buffer ensures cooling effects and stable pH value for running gel at high voltage. Integrated transparent safety lid avoids electricity leakage and sample volatilizing in the cell. Inclusive long life platinum electrodes and high transparent material for gel molding.
Buy Now Download CatalogSpecifications
Gel trays (W x L) | 140 x 140 mm, 140 x 70 mm, 70 x 70 mm |
Buffer volume | 900 mL |
No of samples | 1 to 87 |
Rows of comb | 1 ~3 |
Comb thickness | 1 mm, 1.5 mm |
Gel tray thickness | 2 mm |
Gel making mode | Gel box |
Dimensions (L x W x H) | 360 x 187 x 63 mm |
Weight | 2 kgs |
Features
Applications
Used in molecular biology, forensic science, research and diagnostic lab, microbiology, biochemistry to separate DNA, RNA and proteins for DNA fingerprinting, drug testing, protein analysis, genetic testing, PCR amplification, sample quantification, etc.
Standard Accessories
Sr No | Accessory name | Quantity |
---|---|---|
1 | Body tank with electrode | 1 |
2 | Gel tray (140 x 140 mm) | 1 |
3 | Gel tray (140 x 70 mm) | 1 |
4 | Gel tray (70 x 70 mm) | 2 |
6 | Gel box | 1 |
7 | 1.5 mm thickness 1/2/3 wells comb | 1 |
8 | 1.0 mm thickness 6/14 wells comb | 1 |
9 | 1.0 mm thickness 8/17 wells comb | 2 |
10 | 1.0 mm thickness 13/29 wells comb | 2 |
11 | Buffer saving module | 2 |
12 | Electrical cable | 1 |
What our customers say
Ali Jaffal
9 months ago
Anil Bagati
2 years ago
Amer .
2 years ago
Sajjad Hussain
2 months ago
Laura Jurkevi?i?t?
8 months ago
Prince Lawrence Iroajanma
2 years ago
Tarakeswar Nath
1 year ago
S. Kavidhas
3 years ago
Mian Sadiq Shah
2 years ago
Chamoda Supun
4 months ago
Caleb Otieno Ochola
8 months ago
SACHINI SAMUDIKA
3 years ago
Ekrima Yahya Abu Arra
9 months ago
Mae .
2 years ago
Muhammad Ali
2 years ago
Eng Basit Ali
2 weeks ago
Arshad Mahmood
2 years ago
Add a review
Gel trays (W x L) | 130 x 130 mm, 78 x 100 mm, 48 x 75 mm |
Buffer volume | 600 mL |
No of samples | 3 to 104 |
Rows of comb | 1 ~ 4 |
Gel trays (W x L) | 200 x 200 mm, 200 x 150 mm, 200 x 100 mm |
Buffer volume | 1800 mL |
No of samples | 17 to 104 |
Rows of comb | 1 ~ 6 |
Gel trays (W x L) | 60 x 60 mm, 120 x 60 mm, 60 x 120 mm, 120 x 120 mm |
Buffer volume | 550 ml |
Comb thickness | 1 mm and 1.5 mm |
Comb throughput | 1, 2, 3, 6, 8, 11, 13, 18, 25 samples |
Gel trays (W x L) | 48 x 75 mm |
Buffer volume | 150 ml |
Comb thickness | 1 mm and 1.5 mm |
Comb throughput | 3, 5, 9 samples |
Gel trays (W x L) | 120 x 120 mm, 120 x 60 mm, 60 x 120 mm, 60 x 60 mm |
Buffer volume | 550 mL |
No of samples | 1 to 100 |
Rows of comb | 1 ~ 4 |
Gel trays (W x L) | 48 x 75 mm |
Buffer volume | 150 mL |
No of samples | 3 to 18 |
Rows of comb | 1 ~ 2 |
Gel trays (W x L) | 245 x 250 mm |
Buffer volume | 2000 mL |
No of samples | 19 to 364 |
Rows of comb | 1 ~ 7 |
Gel trays (W x L) | 200 x 200 mm, 200 x 150 mm, 200 x 100 mm |
Buffer volume | 1800 ml |
Comb thickness | 1 mm and 1.8 mm |
Comb throughput | 17, 22, 36, 44 samples |
Gel Size (L × W) | 60 × 60 mm 60 × 120 mm 120 × 60 mm 120 × 120 mm |
Number of Samples | 2 to 100 |
Buffer Volume | 650 ml |
Comb | 2 + 3 wells 6 + 3 wells 8 + 18 wells 11 + 25 wells |
Gel trays (W x L) | 78 x 100 mm |
Buffer volume | 400 mL |
No of samples | 10 to 30 |
Rows of comb | 1 ~ 2 |
Labotronics cellulose acetate membrane electrophoresis unit is a laboratory apparatus used for the separation of proteins and other biomolecules. It employs cellulose acetate membrane strips, which function as the supporting matrix for electrophoresis. Our acetate membrane electrophoresis is a versatile technique used in biochemical research, clinical diagnostics, and quality control applications in various industries. It offers a cost-effective and efficient means of separating and analyzing biomolecules, making it a valuable tool for researchers and scientists
Bridge dimension (W x L) | 66 x 250 mm 82 x 250 mm |
Cell membrane dimension (W x L) | 70 x 90 cm |
Buffer capacity | 560 mL |
Thickness of cellulose acetate membrane | < 1 mm |
Bridge dimension (W x L) | (70 x 250) mm x 2 (90 x 250) mm x 2 |
Cell membrane dimension (W x L) | 70 x 90 cm |
Buffer capacity | 1000 mL |
Thickness of cellulose acetate membrane | < 1 mm |
Labotronics rapid electrophoresis unit is an innovative laboratory instrument designed to expedite the separation and analysis of nucleic acids, primarily DNA and RNA. It employs cutting-edge technology to significantly reduce the time required for electrophoresis, allowing for quicker results in molecular biology and genomics research. Rapid Electrophoresis Units are invaluable in applications like DNA sizing, quantification, and purity assessment, enabling researchers to streamline their workflows, save time, and enhance overall productivity in genetic analysis and molecular diagnostics.
Gel tray (W x L) | 85 x 200 mm |
Buffer volume | 50 mL |
No of samples | 10 to 216 |
Rows of combs | 1 ~ 12 |
Our Electrophoresis Power Supplies provides precise voltage and current control for various electrophoretic applications. The eco-friendly designs incorporate energy-efficient technologies to reduce carbon footprints and comply with stringent environmental regulations. They are equipped with digital displays for real-time monitoring of parameters. Their compact, lightweight design allows for easy integration into any lab environment. Labotronics electrophoresis power supplies are designed for various laboratory applications, including nucleic acid and protein electrophoresis.
Output Voltage | 6 to 600 V |
Output Current | 4 to 400 mA |
Output Power | 240 W |
Output Terminal | 4 pairs in parallel |
Labotronics vertical electrophoresis unit is a fundamental laboratory instrument employed for the separation and analysis of macromolecules, such as DNA, RNA, and proteins, based on their size and charge. It comprises a vertical gel chamber with two vertical glass or plastic plates that sandwich a gel matrix, usually composed of agarose or polyacrylamide. Samples are loaded into wells within the gel, and upon the application of an electric field, the molecules migrate vertically through the gel matrix. Our vertical electrophoresis units offer the flexibility to accommodate a wide range of molecular sizes, and they play a pivotal role in research, diagnostics, and quality control across multiple scientific disciplines, enabling efficient analysis and characterization of biomolecules.
Gel area (W x L) | 186 x 205 mm |
Glass plate area (W x L) | 216 x 220 mm |
Buffer volume | 3500 mL |
No of samples | 25,40, 52 samples |
Gel area (W x L) | 82 x 88 mm |
Glass plate area (W x L) | 100 x 100 mm |
Buffer volume | 750 mL |
No of samples | 11 to 30 |
Glass tray (W x L) | 216 x 220 mm |
Gel tray (W x L ) | 186 x 205 mm |
Comb thickness | 1 mm |
Comb throughput | 25, 40, 52 samples |
Gel area (W x L) | 186 x 205 mm |
Glass plate area (W x L) | 216 x 220 mm |
Buffer volume | 3500 mL |
No of samples | 25, 40, 52 samples |
Our 2D Gel Electrophoresis Unit is a specialized laboratory apparatus used for the separation and analysis of complex mixtures of proteins or nucleic acids. It employs a two-dimensional separation technique to provide higher resolution and detailed information about the components within a sample. This technique is widely used in molecular biology, proteomics, and genomics research to study protein expression, post-translational modifications, and biomarker discovery, offering valuable insights into various biological processes and diseases. Our 2D Gel Electrophoresis Units are essential tools for scientists and researchers aiming to unravel the complexities of biomolecules.
Glass Tube Length | 120 mm (1D) |
Gel Size (W × L) | 143 × 139 mm (2D) |
Number of Samples | 17 to 58 |
Buffer Volume | 2500 ml |
Categories
Best Seller