Multitest Analyzer LB-12MTA is a tabletop unit with quality control for normal and abnormal values, automatic statistics and analysis of control data. Features built-in thermal printer for permanent printing by thermal wax transfer. Provision for Multilanguage feature makes it user-friendly.
Buy Now Download CatalogSpecifications
Function | Chemistry + Coagulation + Specific Protein |
Sample Volume | 50 µL to 500 µl |
Wavelength | Chemistry: 340 nm,405 nm , 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Coagulation: 450 nm, 670 nm Specific protein: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions , controlled at 37 °C ± 0.5 °C |
Test Menu | Chemistry: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Coagulation: 450 nm, 670 nm Specific Protein: 450 nm, 670 nm |
Temperature for Cuvette | 37 °C ± 0.1 °C |
Drift | ≤ 0.0001 OD/hr |
Display | 7-inch touchscreen |
Storage | 1000 test results |
Connection Port | USB & RS232 |
Power | 110 V / 60 Hz, or 220 V/ 50 Hz, 150 W |
Dimensions | 340 ×380 ×210 mm |
Weight | 6.5 kgs |
Features
Applications
Used for the analysis of various biological components in fields such as pathology, medical microbiology, and research purposes.
What our customers say
Raluca Popovici
9 months ago
Jean Claude HABARUGIRA
1 year ago
Rafiki .
1 year ago
Jenan Naem Bouzia
1 month ago
Add a review
Function | Chemistry + Specific Protein |
Sample Volume | 100 µL to 500 µL |
Wavelength | Chemistry: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Specific Protein: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions, controlled at 37 °C ± 0.5 °C |
Function | Chemistry + Coagulation |
Sample Volume | 50 µL to 500 µL |
Wavelength | Chemistry: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 620 nm, 670 nm Coagulation: 450 nm, 670 nm |
Incubator | 2 reagent and 20 sample incubation positions, controlled at 37 °C ± 0.5 °C |
A salt content analyzer is a specialized instrument used to precisely measure the concentration of salt or sodium chloride in various substances, particularly in food products and liquid solutions. These analyzers employ different methods, such as conductivity, titration, or ion-selective electrodes, to determine the amount of salt present. This data is crucial for quality control in the food industry, enabling manufacturers to ensure that products meet flavor, safety, and labeling standards. Salt content analyzers are also used in various other applications, including environmental monitoring and research, where accurate measurement of salinity in water samples is essential.
Halide concentration range | 0.002 % ~ 0.02 % |
Insulating resistance | ≥ 2 MΩ |
Extractor | Potentiometric standard as per ASTM D6470 |
Heating power of extractor | 300 W |
Nitrogen Analyzer is a scientific instrument designed to quantify the nitrogen content in various substances. Employing techniques such as combustion, chemiluminescence, or infrared spectroscopy, it accurately measures nitrogen levels in samples like soil, plant material, or organic compounds. Widely used in agriculture, environmental science, and industrial settings, the analyzer aids in optimizing fertilizer application, assessing soil health, and monitoring pollution. Its precision and speed make it a crucial tool for researchers and professionals, facilitating data-driven decisions and promoting efficient resource management.
Sample Types | Solid, Gas, Liquid |
Working Principle | Chemiluminescence method (N) |
Sample Injection Quantity | Solid: 1to 20 mg Liquid: 5 to 20 μL Gas: 1to 5 mL |
Measuring Range | 0.05 to 20000 ppm (mg/L) (High concentration diluted) |
Measuring range | 79.0% to 99.9% |
Sample Gas Flow | 150 to 300 ml/min |
Visible Display Window | 90 × 25 mm |
Accuracy | ±2% F. S |
Our Portable Coal Content Analyzers offer fast and accurate analysis of coal properties in various field environments. These analyzers provide real-time measurement of key coal content parameters such as moisture, ash, and volatile matter. They are equipped with high-precision sensors to ensure reliable and consistent results. Their data storage capability allows for record-keeping and easy analysis of results. Their user-friendly interface simplifies operation, requiring minimal training. Our portable coal content analyzers feature a durable construction designed to withstand harsh field conditions, ensuring longevity and reliability.
Clean Coal Ash Content Error | ≤ 1.0% (Low Ash Coal) |
Clean Coal Calorimeter Error | 120 cal/g |
Clean Coal Moisture Error | ≤ 1% |
Thermal Coal Ash Content Error | ≤ 2.5% (High Ash Coal) |
Our wide range of cetane analyzer is a specialized instrument used in the petroleum and automotive industries to measure the cetane number of diesel fuel. The cetane number is a critical parameter that determines the ignition quality of diesel fuel, with higher values indicating better ignition performance. Cetane analyzers typically utilize a combustion chamber and optical sensors to evaluate the ignition delay period of the fuel. This data assists in assessing the fuel's quality, combustion efficiency, and potential for engine knock or noise. By ensuring diesel fuel meets specific cetane number requirements, these analyzers help optimize engine performance, reduce emissions, and improve fuel economy.
Engine speed | 900 rpm ± 9 rpm |
Piston stroke | 114.3 mm |
Cylinder bore diameter | 82.55 mm |
Compression ratio range (adjustable) | 8:1 ~ 36:1 |
Labotronics Infrared Oil Content Analyzer is a sophisticated instrument designed for accurate measurement of oil content in various samples. Utilizing infrared technology, this analyzer determines the concentration of oil by analyzing the absorption of specific wavelengths of infrared light. Its precision and reliability make it an essential tool in industries such as food, cosmetics, and petrochemicals, where precise measurement of oil content is crucial for quality control. The user-friendly interface and rapid analysis capabilities streamline the testing process, enabling efficient and reliable results.
Measurement Range | 0.001 to 2000 mg/L (4 cm cuvette) |
Detection Limit | ˂ 0.12 mg/L (direct measurement) ˂ 0.0012 mg/L (oil in water) |
Measurable Concentration | ≤ 640000 mg/L (dilution) |
Accuracy | ± 0.5% ( |