Atomic Absorption Spectrophotometer LB-11AAS is a double beam source system for trace elemental analysis. It features pre-heating cathode lamp system for quick and optimized sample analyzing. It is equipped with multi-functional analysis mode and durable anti-corrosive atomization system.
$ 12737.5
Download Catalog Download ManualSpecifications
| Wavelength range | 190 nm ~ 900 nm |
| Wavelength accuracy | ± 0.5 nm |
| Wavelength repeatability | ≤ 0.3 nm (single direction) |
| Base line stability | ± 0.004 Abs / 30 min |
| Spectral bandwidth | 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0 |
| Resolution | < 40% |
| Characteristic concentration | ≤ 0.04 µg / mL / 1% (Cu) |
| Detection limit | ≤ 0.08 µg / mL (Cu) |
| Background calibration | > 30 times |
| Power | 220 V / 50 Hz |
| Dimensions ( W × D × H ) (Standard accessories) | 550 × 460 × 1350 mm |
| Dimensions ( W × D × H ) (Main unit) | 1250 × 800 × 750 mm |
| Gross weight (Standard accessories) | 50 kgs |
| Gross weight (Main Unit) | 150 kgs |
Features
Standard Accessories
| Sr. No. | Name of the accessory | Quantity |
|---|---|---|
| 1. | RS232 serial port | 1 |
| 2. | Oil-free air compressor | 1 |
| 3. | Glass atomizer | 1 |
| 4. | Cu Hollow cathode lamp | 1 |
| 5. | Printer | |
| 6. | Atomizer unit | 1 |
| 7. | Burner unit | 1 |
| 8. | Dust cover | 1 |
| 9. | Water separating gas filter | 1 |
| 10. | Titanium burner- 10 cm | 1 |
Optional Accessories
| Sr. No. | Name of the accessory |
|---|---|
| 1. | Graphite furnace |
| 2. | Hydride generator |
| 3. | Recirculating cooling water system |
Applications
Used for the quantitative determination of particular analytes in the fields of environmental analysis, geology, metallurgy, petrochemical industries, food and beverages, medicines, ceramic, paints, chemical industries, etc.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Wavelength range | 190 nm ~ 900 nm |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength repeatability | ≤ 0.04 nm |
| Base line stability | ≤ 0.002 A / 30 min (Cu) |
| Grating | 1800 lines/mm |
| Wavelength Coverage | 190 to 900 nm |
| Lamp Configuration | 66 hollow cathode lamps |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm (full wavelength range) |
| Absorbance Range | 0 to 2.5 ABS |