Atomic Absorption Spectrophotometer LB-12AAS

Atomic Absorption Spectrophotometer LB-12AAS

Atomic Absorption Spectrophotometer LB-12AAS features a 190 to 900 nm wavelength range with ±0.2 nm accuracy. It supports both flame and graphite furnace atomization with fast mode switching. It is fully automatic and PC-controlled, ensuring stable and reliable performance. The system is equipped with a PID-controlled graphite furnace and an 85-position high-precision autosampler for consistent results.

$ 29525

Download Catalog

Specifications

Wavelength Coverage 190 to 900 nm
Lamp Configuration 66 hollow cathode lamps
Wavelength Repeatability ±0.1 nm
Wavelength Accuracy ±0.2 nm (full wavelength range)
Absorbance Range 0 to 2.5 ABS
Raster / Grating 1800 lines/mm
Spectral Bandwidth Levels 0.1, 0.2, 0.4, 0.7, 1.0, 2.0 nm
Optical Resolution 0.2 nm bandwidth separates Mn double lines (279.5 / 279.8 nm), valley-peak energy ratio < 20%
Static Baseline Drift ≤ 0.002 ABS / 30 min (Cu)
Background Correction Background signal of 1 ABS reduced by ≥ 50 times (D₂ Lamp)
Flame Atomization Mode Air–acetylene flame
Flame Burner Head Length 100 mm
Flame Dynamic Baseline Drift ≤ 0.004 ABS / 30 min (Cu)
Flame Sensitivity ≤ 0.025 μg/mL / 1% (Cu)
Flame Detection Limit ≤ 0.004 μg/mL (Cu)
Flame Precision ≤ 0.5% (Cu, absorbance > 0.8 ABS) (RSD)
Flame Safety Protection Inadequate pressure, power failure, abnormal flame-out, automatic gas cut-off, burner mismatch protection
Flame Sensor High-sensitivity flame sensor
Graphite Furnace Working Temperature Room temperature to 3000 °C
Maximum Heating Rate ≥ 2000 °C/s
Temperature Control Method PID temperature control
Graphite Furnace Characteristic Mass Cd ≤ 1 pg; Cu ≤ 10 pg
Graphite Furnace Precision Cd ≤ 3%; Cu ≤ 3% (RSD)
Graphite Furnace Safety Overcurrent protection
Gas Pressure Alarm Automatic alarm and stop heating
Cooling Water Flow Alarm Automatic alarm and stop heating
Graphite Furnace Visual System CCD camera real-time monitoring inside graphite tube
Visual Monitoring Functions Capillary needle depth, platform position, drying/ashing/atomization process
Autosampler Type Automatic sampler
Autosampler Capacity 85 positions
Autosampler Functions Automatic injection, automatic dilution, automatic standard curve configuration
Injection Accuracy High-precision injection
Flame & Furnace Switching Mode switching within 10 seconds
Overall Safety System Comprehensive operator protection
Graphite Furnace Power Consumption 7000 W
Graphite Furnace Power Supply 220 V AC
Graphite Furnace Dimensions 550 × 450 × 280 mm
Host Dimensions 500 × 450 × 430 mm
Graphite Furnace Weight 60 kg
Host Weight 80 kg

Features

Fast mode switching without mechanical adjustment

Stable optical-mechanical design

Real-time graphite furnace visual monitoring

Advanced safety with automatic gas shut-off

Intelligent software with method & curve storage

Standard Accessories

Low Noise Oil Free Air Compressor

Hydrogen Generators

Host Attachments

Graphite Furnace Section

Applications

Atomic Absorption Spectrophotometer LB-12AAS is used for trace and heavy metal elemental analysis in food, pharmaceuticals, environmental, and material samples. It is used in research labs, quality control laboratories, and environmental monitoring facilities.

Get Quote

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Atomic Absorption Spectrophotometer

Atomic Absorption Spectrophotometer LB-10AAS

Wavelength range 190 nm ~ 900 nm
Wavelength accuracy ± 0.15 nm
Wavelength repeatability ≤ 0.04 nm
Base line stability ≤ 0.002 A / 30 min (Cu)
Grating 1800 lines/mm

$ 24075

Atomic Absorption Spectrophotometer LB-11AAS

Wavelength range 190 nm ~ 900 nm
Wavelength accuracy ± 0.5 nm
Wavelength repeatability ≤ 0.3 nm (single direction)
Base line stability ± 0.004 Abs / 30 min
Spectral bandwidth 0.2 nm, 0.4 nm, 0.7 nm, 1.4 nm, 2.4 nm, 5.0