| COD Measuring Range | 10 to 15000 mg/L |
| COD Detection Method | Potassium Dichromate Method Potassium Permanganate method |
| COD Detection Lower Limit | 10 mg/L |
| COD Digestion Temperature & Time | 165 °C, 20 min |
| COD Accuracy | ≤±5% or ±4 mg/L |
| COD Repeatability | ≤3% |
| Ammonia Nitrogen Measuring Range | 0.02 to 100 mg/L |
| Ammonia Nitrogen Detection Method | Salicylic Acid Method |
| Ammonia Nitrogen Detection Lower Limit | 0.02 mg/L |
| Ammonia Nitrogen Accuracy | ≤±5% or ±0.1 mg/L |
| Ammonia Nitrogen Repeatability | ≤3% |
| Total phosphorus Measuring Range | 0.02 to 20 mg/L |
| Total phosphorus Detection Method | Ammonium Molybdate Method |
| Total phosphorus Detection Lower Limit | 0.02 mg/L |
| Total phosphorus Digestion Temperature & Time | 150 °C, 15 min |
| Total phosphorus Accuracy | ≤±5% or ±0.04 mg/L |
| Total phosphorus Repeatability | ≤3% |
| Total Nitrogen Measuring Range | 0.5 to 500 mg/L |
| Total Nitrogen Detection Method | Thymol Method |
| Total Nitrogen Detection Lower Limit | 0.5 mg/L |
| Total Nitrogen Digestion Temperature & Time | 125 °C, 30 min |
| Total Nitrogen Accuracy | ≤±5% or ±0.4 mg/L |
| Total Nitrogen Repeatability | ≤3% |
| Light Source Life | 100,000 hours |
| Accuracy | ≤±5% |
| Filter Life | 5 years |
| Absorbance | 0 to 3.5 Abs |
| Absorbance Stability | ≤ ± 0.002 Abs/30 min |
| Absorbance Resolution | 0.001 Abs |
| Operation Repeatability | ≤ ± 0.005 Abs |
| Operating Temperature | 0 to 50 ℃ |
| Relative Humidity | 0 to 90% (non-condensing) |
| Data Storage | 10,000 pcs |
| Power Supply | DC 12V/5A |
| Dimensions (W × D × H) | 412 × 253 × 164 mm |
| 01 Box Packing dimensions (W × D × H) | 470 × 390 × 210 mm |
| 02 Box Packing dimensions (W × D × H) | 50 × 64 × 26 mm |
| Net weight | 3.25 kg |
| 01 Box Gross weight | 5.16 Kg |
| 02 Box Gross weight | 17.6 Kg |
Features
Standard Accessories
ReagentsApplications
Benchtop Multiparameter Meter is ideal for use in chemical engineering, water treatment plants, metallurgy, and forging.Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Temperature Parameters | Range: -5 to 110 ºC, 23 to 230 ºF Unit: ºC, ºF Resolution: 0.1 Accuracy: ±0.2 |
| Measurement Modes | Reading Mode: Auto Read (Fast, Medium, Slow), Timed, Continuous Reading Prompts: Reading, Stable, Locked, Temp. Compensation: ATC, MTC |
| Parameters | pH/ EC/ ISE/ Temp. (mV/ ORP/ pX/ Resistivity/ TDS /Sal.) |
| pH | Range: -2.00 to 20.00 ph Resolution: 0.1, 0.01 pH Accuracy: ±0.01 pH Calibration Points: Up to 5 Standard Recognition: NIST, GB, and DIN buffers Slope Limit |
| mV | Range: -2000.0 to 2000.0 mV Resolution: 0.1 mV Accuracy: ±0.3 mV or ±0.1% |
| Measuring parameters | pH/EC/ISE/Temperature (mV/ORP/pX/Resistivity/TDS/Salinity) |
| Measuring range | pH: -2.000 to 20.000 pH mV/ORP: -2000.00 to 2000.00 mV pX range: -2.000 to 20.000 pX ISE: 1E-9 to 9.999E9 Conductivity: 0.000 µS/cm to 2000 mS/cm Resistivity: 5.00 Ω·cm to 100.00 MΩ·cm TDS: 0.000 to 1000 ppt Salinity: 0.0 to 80.0 ppt Temperature: -10 to 135°C, 14 to 275°F |
| Resolution | pH: 0.1, 0.01, 0.001 pH mV/ORP: 0.1, 0.01 mV pX: 0.1, 0.01, 0.001 pX ISE: Up to 4 significant units Conductivity: 0.001 µS/cm Resistivity: 0.01 Ω·cm TDS: 0.001 ppm Salinity: 0.1 ppt Temperature: 0.1°C/°F |
| Accuracy | pH: ±0.002 pH mV/ORP: ±0.1 mV or ±0.03% pX: ±0.002 pX ISE: ±0.3% Conductivity: ±0.5%FS Resistivity: ±0.5% FS TDS: ±0.5% Salinity: ±1 ppt Temperature: ±0.1 °C/°F |
| Calibration points | pH: Up to 6 ORP: 1 custom point (relative mV) pX: Up to 6 ISE: Up to 6 Conductivity: Up to 5 |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026