CO2 Incubator LB-14COI operates within a temperature range of 4°C to 60°C and offers a 185L capacity, delivering precise and reliable sample incubation. It integrates an ISO Class 5 HEPA air filtration system, ensuring contaminant-free air circulation. Our incubator features 140°C high-heat sterilization to effectively eliminate contaminants. It includes a 5-inch LCD touchscreen, allowing for easy monitoring of environmental conditions.
$ 6437.5
Download CatalogSpecifications
| Capacity | 185 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Working Temperature Range | 10°C to 30°C |
| Relative Humidity | Up to 95% RH at 37°C |
| CO2 Control Range | 0 to 20% |
| CO2 Supply | 0.05 to 0.1MPa |
| CO2 Concentration Recovery Time | ≤5 Min (door opened for 30 seconds, set value 5%) |
| CO2 Measurement Principle | Infrared (IR) detection |
| CO2 Display Resolution | 0.1% |
| Timing Function | 0 to 999.9 hours |
| Sterilization Method | 140°C High heat sterilization |
| Filtration | HEPA (ISO Class 5), effective within 5 minutes |
| Display | 5-Inch LCD Touchscreen |
| Scalability | Stackable up to 2 units |
| User Management | 3 levels of user access (Administrator / Tester / Operator) |
| Historical Data Storage | 250,000 messages |
| Data Export Interface | USB interface |
| Power Consumption | 900W |
| Power Supply | 115/230V±10%, 50/60Hz |
| Internal Dimension (W × D × H) | 535 × 526 × 675 mm |
| External Dimension (W × D × H) | 660 × 652 × 1000 mm |
| Packaging Dimension (W × D × H) | 730 × 725 × 1175 mm |
| Net Weight | 112 kg |
| Gross Weight | 138 kg |
Features
Applications
CO2 Incubator LB-14COI is used for cultivating sensitive cell and tissue cultures under controlled temperature and CO2 conditions. It is ideal for use in research labs, hospitals, pharmaceutical companies, and academic institutions.
Frequently asked questions For CO2 Incubator
1. Can multiple users access the Labotronics LB-14COI with different permission levels?
Yes, the Labotronics LB-14COI CO? Incubator offers a secure three-level user management system. Administrators have full access rights, while testers and operators are assigned role-based limitations. This access control ensures secure operation and prevents unauthorized changes to incubation settings.
2. Is there any risk of overheating or parameter deviation during operation of the LB-14COI?
No, the Labotronics LB-14COI CO? Incubator features built-in over-temperature protection and continuous real-time monitoring. If the internal temperature exceeds safe limits, an automatic alarm is triggered and the system takes corrective action to preserve ideal incubation conditions.
3. Can I run sterilization cycles in the LB-14COI without removing cultures?
No, during its 140°C high-heat sterilization cycle, the internal chamber reaches temperatures unsuitable for live cultures. Labotronics recommends removing all samples and accessories before initiating sterilization to avoid sample damage or loss.
4. What happens if the door of the Labotronics LB-14COI is opened frequently? Will the internal environment be affected?
Opening the door may temporarily disturb the internal environment. However, the Labotronics LB-14COI CO? Incubator is engineered for rapid recovery. Its active airflow circulation and infrared CO? sensor quickly restore stable conditions, ensuring minimal disruption to cell and tissue cultures.
5. What is a CO2 incubator and why is it important in biological research?
A CO2incubator is a laboratory device used to cultivate cells under controlled environmental conditions. It maintains stable temperature, humidity, and carbon dioxide levels to create an optimal environment for cell growth.
6. How is a CO2 incubator different from a standard laboratory incubator?
Unlike standard incubators that only control temperature, CO2 incubators regulate CO2concentration and humidity, making them suitable for mammalian cells and pH-sensitive media.
7. What types of samples or cultures can be grown in a CO2 incubator?
CO? incubators are suitable for growing mammalian cells, stem cells, cancer cells, embryos (IVF), and engineered tissues. Our models are widely used in clinical labs, biotech companies, and academic research facilities due to their reliability and performance.
8. Why is HEPA filtration important in CO2 incubators?
A HEPA filter removes airborne contaminants such as bacteria, dust, and mold spores, ensuring a sterile culture environment. Labotronics incubators feature ISO Class 5 HEPA filtration, which effectively purifies chamber air within minutes, minimizing contamination risks in long-term cultures.
9. Can CO2 incubators support anaerobic or hypoxic environments?
Yes, Labotronics advanced CO2incubators allow oxygen control and nitrogen gas integration to create hypoxic or anaerobic conditions, ideal for cancer biology, hypoxia studies, and low-O2 stem cell cultures, where precise gas regulation is essential.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 85 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤ 10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 120 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 248L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 180 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 248 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 40 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 260 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.4 °C (at 37 °C / RT 20 °C) |
| Capacity | 180 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ |
| Capacity | 40 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 120 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 185L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 80L |
| Temperature Range | 5℃ to 60℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Fluctuation | ±0.3℃ (at 37℃) |
| Temperature Uniformity (at 37℃) | ±0.5℃ (at 37℃) |
| Capacity | 40 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Fluctuation | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 260 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.4 ℃ |
| Capacity | 85 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections