CO2 Incubator LB-11COI operates within a temperature range of 5°C to 60°C and has a capacity of 85 L, ensuring reliable sample incubation. It features 140°C high-heat sterilization to effectively eliminate microbial contamination. It includes a HEPA filtration system that rapidly purifies the air to maintain a sterile environment. Our incubator is equipped with a 5-inch LCD touchscreen, enabling real-time temperature monitoring and control.
$ 6256.25
Download CatalogSpecifications
| Capacity | 85 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤ 10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Working Temperature Range | 18°C to 30°C |
| Relative Humidity | Up to 95% RH at 37°C |
| CO2 Control Range | 0 to 20% |
| CO2 Supply | 0.05 to 0.1mpa |
| CO2 Concentration Recovery Time | ≤5 Min (door opened for 30 seconds, set value 5%) |
| CO2 Measurement Principle | Infrared (IR) detection |
| CO2 Display Resolution | 0.1% |
| Timing Function | 0 to 999.9 hours |
| Sterilization Method | 140°C High heat sterilization |
| Filtration | HEPA (ISO Class 5), effective within 5 minutes |
| Display | 5-Inch LCD Touchscreen |
| Scalability | Stackable up to 2 units |
| User Management | 3 levels of user access (Administrator / Tester / Operator) |
| Historical Data Storage | 250,000 messages |
| Data Export Interface | USB interface |
| Power Consumption | 500W |
| Power Supply | 115/230V ±10%, 50/60Hz |
| Internal Dimension (W × D × H) | 440 × 400 × 500 mm |
| External Dimension (W × D × H) | 560 × 530 × 825 mm |
| Packaging Dimension (W × D × H) | 700 × 645 × 940 mm |
| Net Weight | 78 kg |
| Gross Weight | 98 kg |
Features
Applications
CO2 Incubator LB-11COI is used for cultivating cell cultures, tissue cultures, and microbial samples. It is widely used in research laboratories, clinical diagnostics, and pharmaceutical development.
Frequently asked questions For CO2 Incubator
1. How does the LB-11COI ensure a contamination-free environment for sensitive cultures?
Labotronics’ LB-11COI combines 140°C high-heat sterilization with an ISO Class 5 HEPA filtration system to eliminate microbial contaminants. It’s ideal for sterile cell culture, pharmaceutical research, and biomedical applications.
2. How does the six-sided heating system improve incubation performance?
Unlike conventional models, the LB-11COI features six-sided heating to ensure uniform temperature distribution throughout the chamber. This eliminates hot or cold zones and supports precise incubation of multiple samples.
3. How does Labotronics' incubator help reduce downtime during experiments?
The LB-11COI offers rapid recovery of both temperature and CO2 levels after door openings, protecting sensitive samples and minimizing disruptions in continuous or time-critical cultivation workflows.
4. Is this LB-11COI incubator suitable for long-term studies or high-throughput applications?
Yes. Labotronics' LB-11COI is designed for scalability and efficiency, offering stable environmental conditions, large data storage, and a stackable form, ideal for extended research and high-volume laboratory operations.
5. Can the LB-11COI be integrated with external monitoring systems?
Yes, the LB-11COI offers data logging and external communication interfaces, making it compatible with remote monitoring setups for continuous performance tracking.
6. What is a CO2 incubator and why is it important in biological research?
A CO2incubator is a laboratory device used to cultivate cells under controlled environmental conditions. It maintains stable temperature, humidity, and carbon dioxide levels to create an optimal environment for cell growth.
7. How is a CO2 incubator different from a standard laboratory incubator?
Unlike standard incubators that only control temperature, CO2 incubators regulate CO2concentration and humidity, making them suitable for mammalian cells and pH-sensitive media.
8. What types of samples or cultures can be grown in a CO2 incubator?
CO? incubators are suitable for growing mammalian cells, stem cells, cancer cells, embryos (IVF), and engineered tissues. Our models are widely used in clinical labs, biotech companies, and academic research facilities due to their reliability and performance.
9. Why is HEPA filtration important in CO2 incubators?
A HEPA filter removes airborne contaminants such as bacteria, dust, and mold spores, ensuring a sterile culture environment. Labotronics incubators feature ISO Class 5 HEPA filtration, which effectively purifies chamber air within minutes, minimizing contamination risks in long-term cultures.
10. Can CO2 incubators support anaerobic or hypoxic environments?
Yes, Labotronics advanced CO2incubators allow oxygen control and nitrogen gas integration to create hypoxic or anaerobic conditions, ideal for cancer biology, hypoxia studies, and low-O2 stem cell cultures, where precise gas regulation is essential.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 40 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Fluctuation | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 260 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.4 ℃ |
| Capacity | 120 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 248L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 85 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 260 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.4 °C (at 37 °C / RT 20 °C) |
| Capacity | 120 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 180 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 160 L |
| Temperature Range | RT+5℃ to 60℃ |
| CO2 Range | 0 to 20% |
| Convection Mode | Forced Convection |
| CO2 Sensor/Uniformity | IR sensor (±0.1%) |
| Capacity | 185 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 80L |
| Temperature Range | 5℃ to 60℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Fluctuation | ±0.3℃ (at 37℃) |
| Temperature Uniformity (at 37℃) | ±0.5℃ (at 37℃) |
| Capacity | 248 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 185L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 180 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ |
| Capacity | 40 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |