CO2 Incubator LB-15COI offers a spacious 185L chamber and maintains a precise temperature range from 4°C to 60°C. It features a 6-side direct heat chamber system, ensuring uniform temperature distribution. It uses infrared (IR) detection technology for accurate and stable CO2 concentration measurement. Our incubator includes a high-efficiency HEPA filtration system and a user-friendly LCD touchscreen, providing optimal conditions for reliable cell and tissue cultivation.
$ 10187.5
Download CatalogSpecifications
| Capacity | 185L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Working Temperature Range | 10°C to 30°C |
| Relative Humidity | Up to 95% RH at 37°C |
| CO2 Control Range | 0 to 20% |
| CO2 Supply | 0.05 to 0.1MPa |
| CO2 Concentration Recovery Time | ≤5 Min (door opened for 30 seconds, set value 5%) |
| CO2 Measurement Principle | Infrared (IR) detection |
| CO2 Display Resolution | 0.1% |
| Timing Function | 0 to 999.9hours |
| Sterilization Method | 180°C High heat sterilization |
| Filtration | HEPA (ISO Class 5), effective within 5 minutes |
| Display | 5-Inch LCD Touchscreen |
| Scalability | Stackable up to 2 units |
| User Management | 3 levels of user access (Administrator / Tester / Operator) |
| Historical Data Storage | 250,000 messages |
| Data Export Interface | USB interface |
| Power Consumption | 900W |
| Power Supply | 115/230V±10%, 50/60Hz |
| Internal Dimension (W × D × H) | 535 × 526 × 675 mm |
| External Dimension (W × D × H) | 660 × 652 × 1000 mm |
| Packaging Dimension (W × D × H) | 730 × 725 × 1175 mm |
| Net Weight | 112 kg |
| Gross Weight | 138 kg |
Features
Applications
CO2 Incubator LB-15COI is used for precise cultivation of cells and tissues in a controlled CO2 environment. It is widely applied in research labs, clinical diagnostics, and pharmaceutical development.
Frequently asked questions For CO2 Incubator
1. Is the Labotronics LB-15COI CO? incubator suitable for compact laboratory spaces?
The Labotronics LB-15COI CO? incubator features a space-saving, stackable design that allows up to two units to be securely stacked. This makes it a perfect choice for laboratories with limited space, without compromising on chamber capacity or incubation performance.
2. What ensures consistent temperature inside the LB-15COI incubator?
The LB-15COI features a 6-side direct heat chamber system, which ensures uniform temperature distribution throughout the interior. This advanced heating method eliminates hotspots and cold zones, providing a stable environment essential for sensitive cell and tissue cultures.
3. Can I leave my cultures in the Labotronics LB-15COI for more than a week without daily monitoring?
Absolutely. The Labotronics LB-15COI incubator supports long-duration, unattended incubation with features like real-time monitoring, up to 250,000 data records, automatic recovery systems, and alarm notifications. It ensures optimal sample viability over multi-day or multi-week experimental runs.
4. Does the Labotronics LB-15COI incubator support time-sensitive experiments like drug exposure studies or embryo development?
Absolutely. The LB-15COI offers precise environmental control with minimal drift, making it ideal for time-critical applications such as embryonic development, pharmacological response studies, and real-time gene expression analysis. Researchers can rely on its accuracy for experiments that demand consistency.
5. What is a CO2 incubator and why is it important in biological research?
A CO2incubator is a laboratory device used to cultivate cells under controlled environmental conditions. It maintains stable temperature, humidity, and carbon dioxide levels to create an optimal environment for cell growth.
6. How is a CO2 incubator different from a standard laboratory incubator?
Unlike standard incubators that only control temperature, CO2 incubators regulate CO2concentration and humidity, making them suitable for mammalian cells and pH-sensitive media.
7. What types of samples or cultures can be grown in a CO2 incubator?
CO? incubators are suitable for growing mammalian cells, stem cells, cancer cells, embryos (IVF), and engineered tissues. Our models are widely used in clinical labs, biotech companies, and academic research facilities due to their reliability and performance.
8. Why is HEPA filtration important in CO2 incubators?
A HEPA filter removes airborne contaminants such as bacteria, dust, and mold spores, ensuring a sterile culture environment. Labotronics incubators feature ISO Class 5 HEPA filtration, which effectively purifies chamber air within minutes, minimizing contamination risks in long-term cultures.
9. Can CO2 incubators support anaerobic or hypoxic environments?
Yes, Labotronics advanced CO2incubators allow oxygen control and nitrogen gas integration to create hypoxic or anaerobic conditions, ideal for cancer biology, hypoxia studies, and low-O2 stem cell cultures, where precise gas regulation is essential.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 120 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 180 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 40 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 40 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Fluctuation | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 80L |
| Temperature Range | 5℃ to 60℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Fluctuation | ±0.3℃ (at 37℃) |
| Temperature Uniformity (at 37℃) | ±0.5℃ (at 37℃) |
| Capacity | 248L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 180 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 185 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 260 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.4 °C (at 37 °C / RT 20 °C) |
| Capacity | 180 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ |
| Capacity | 248 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 120 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 160 L |
| Temperature Range | RT+5℃ to 60℃ |
| CO2 Range | 0 to 20% |
| Convection Mode | Forced Convection |
| CO2 Sensor/Uniformity | IR sensor (±0.1%) |
| Capacity | 85 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤ 10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 40 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534