



Drying Cabinet LB-52DC maintains an ultra-low humidity environment of less than 5% RH and offers a 240L capacity for the precise storage of sensitive electronics. It features three shelves, each capable of supporting up to 50 kg. It has an ESD-safe coating, ensuring durability and protection. Our drying cabinet is equipped with a high-precision temperature and humidity sensor, providing stable and controlled storage conditions.
$ 2993.75
Download CatalogSpecifications
| Capacity | 240L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Material | 1.2 mm thick galvanized steel with ESD-safe coating |
| Power Consumption | 10W |
| Inner Dimension (W × D × H) | 596 × 372 × 1148 mm |
| Outer Dimension (W × D × H) | 598 × 400 × 1310 mm |
| Net Weight | 42 kg |
| Gross Weight | 57 kg |
Features
Automatic moisture control
Door-opening alarm
Over-humidity alarm
Anti-static protection
Low power consumption
Optional Accessories
Over-Humidity Buzzer Alarm
Open Door Buzzer Alarm
Three-Color Flashing Light Alarm
Data Logging System with USB Interface
Extra Shelf
Applications
Drying Cabinet LB-52DC is used for storing and protecting moisture-sensitive devices like PCBs, semiconductors, and electronic components. It is ideal for electronics manufacturing, research laboratories, aerospace, medical industries, and cleanroom environments
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 1436L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 240L |
| Humidity Range | 10 to 20%RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 320L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 160L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 870L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 98L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 1pc (Height adjustable) |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 718L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 540L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 3pcs (Height adjustable) |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | < 3% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 240L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 870L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 320L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 160L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 3pcs (Height adjustable) |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534
All Sections
Best Seller
Quick Links
Copyright © Labotronics Scientific 2026