Drying Cabinet LB-49DC offers a capacity of 1436L and maintains humidity levels below 10% RH, ensuring reliable storage for sensitive electronics. It has five shelves, each supporting a maximum load of 100 kg for robust storage. The cabinet incorporates an automatic regeneration system, allowing for maintenance-free drying. Additionally, it features a high-precision humidity and temperature sensor for precise humidity control.
$ 4350
Download CatalogSpecifications
| Capacity | 1436L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Material | 1.2 mm thick galvanized steel with ESD-safe coating |
| Power Consumption | 20W |
| Inner Dimension (W × D × H) | 1198 × 682 × 1723 mm |
| Outer Dimension (W × D × H) | 1200 × 710 × 1910 mm |
| Net Weight | 144 kg |
| Gross Weight | 189 kg |
Features
ESD-safe coating
Quick drying time
Smooth mobility wheels
Tempered glass window
Durable construction
Optional Accessories
Over-Humidity Buzzer Alarm
Open Door Buzzer Alarm
Three-Color Flashing Light Alarm
Data Logging System with USB Interface
Extra Shelf
Applications
Drying Cabinet LB-49DC is used for storing and preserving sensitive electronic components. It is ideal for use in electronics manufacturing, semiconductor industries, research laboratories, and PCB assembly units.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 435L |
| Humidity Range | < 5% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 240L |
| Humidity Range | 10 to 20%RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | < 3% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 320L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 98L |
| Humidity Range | < 10%RH Automatic |
| Number of Shelves | 1pc |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 160L |
| Humidity Range | 10 to 20%RH (Adjustable) |
| Number of Shelves | 3 pc |
| Maximum Load Capacity | 50 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 718L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 5pcs (Height adjustable) |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 540L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 5pcs (Height adjustable) |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | 20 to 60% RH (Adjustable) |
| Number of Shelves | 3pcs (Height adjustable) |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | 1 to 60% RH (Adjustable) |
| Number of Shelves | 5pcs (Height adjustable) |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 15 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 1436L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 5pcs |
| Maximum Load Capacity | 100 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 435L |
| Humidity Range | < 10% RH Automatic |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
| Capacity | 540L |
| Humidity Range | 10 to 20% RH (Adjustable) |
| Number of Shelves | 3pcs |
| Maximum Load Capacity | 80 kg/shelf |
| Recovery Time | Maximum 30 min recovery after a 30-sec door opening (Ambient 25℃, 60%RH) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com