Gas Chromatography LB-51GC is equipped with a 16-phase temperature programme with a temperature range of RT to 450 °C. Features an APC controlled Flame Ionization Detector (FID) with high sensitivity for a range of analyses. Dual column compensation function effectively restrains baseline drift. Built-in provision to connect to the internet for data transfer and automated programme upgradation. Packed and capillary column can be installed at the same time.
Buy Now Download CatalogSpecifications
Power supply | AC 110 V / 220 V ± 10 % ; 50 Hz / 60 Hz |
Dimensions ( W x D x H ) | 800 x 570 x 650 mm |
Gross weight | 75 kgs |
Features
Standard Accessories
Accessory No | Accessory |
1. | FID detector |
2. | Chromatography workstation software |
Optional Accessories
Accessory No | Accessory |
1. | Sample Injection System |
2. | TCD detector |
3. | ECD detector |
4. | FPD detector |
5. | NPD detector |
6. | Chromatographic Column |
Applications
Used in the analysis of oil extraction and refining industry, petrochemical analysis, gas industry, quality control of medicines, food and chemicals, in quality supervision of medicines, foods and chemicals and scientific research institutesDetector Specifications
Hydrogen flame Ionization Detector ( FID ) | Detection limit : ≤ 3 x 10-12 g/s ( Sample : N-hexadecane ) |
Baseline drift : ≤ 1 x 10-13 A/30 min | |
Linear range : ≥ 107 | |
Thermal Conductivity Detector ( TCD ) ( Optional ) | Sensitivity : ˃ 10000 mv.ml/mg ( Sample : N-hexadecane ) |
Linear range : ≥ 105 | |
Electron Capture Detector ( ECD ) ( Optional ) | Detection limit : ≤ 1 x 10-14 g/ml ( Sample : N-hexadecane ) |
Linear range : ≥ 103 | |
Flame Photometric Detector ( FPD ) ( Optional ) | Detection limit : ≤ 2 x 10-11 g/s ( S of Thiophene ) |
Detection limit : ≤ 1 x 10-12 g/s ( P of Methyl parathion ) | |
Linear range : ≥ 102 | |
Linear range : ≥ 103 | |
Nitrogen and Phosphorous Detector ( NPD ) ( Optional ) | Detection limit : ≤ 1 x 10-12 g/s ( Azobenzene ) |
Detection limit : ≤ 1 x 10-12 g/s ( Marla Sulphur Phosphorous ) | |
Linear range : ≥ 103 |
Oven Specifications
Temperature range | RT ~ 400 °C |
Temperature accuracy | ± 0.02 °8 |
Temperature programme | 16 phase |
Temperature heating rate | 40 °C / min |
Sample injector temperature range | RT +7 °C ~ 420 °C |
Power supply | AC 220 V ± 10 % ; 50 Hz / 60 Hz |
Dimensions ( W x D x H ) | 1020 x 660 x 740 mm |
Gross weight | 82 kgs |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com