High Performance Liquid Chromatography LB-10HPLC offers a precise solvent flow range of 0.001 to 10.000 mL/min. It features a UV detector with a wavelength range of 190 nm to 700 nm and a deuterium light source that provides high stability and intensity. It is integrated with a VFD screen for intuitive control and real-time monitoring. Our advanced HPLC is used for chemical analysis and in pharmaceutical testing, food safety assessments, and environmental monitoring.
$ 12275
Download CatalogSpecifications
| Flow Range | 0.001 to 10.000 mL/min |
| Flow Rate Increment | 0.001 mL/min |
| Flow Accuracy | ≤ ± 0.3% (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.1% (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 42 MPa |
| Display Pressure Error | ≤ ± 3.0% |
| Pressure Fluctuation | ≤ 1.0% |
| Power Dissipation (Pump) | 80 W |
| Wavelength Repeatability | ± 0.1 nm |
| Wavelength Accuracy | ≤ ± 1.0 nm |
| Spectrum Bandwidth | 8 nm |
| Response Time | 0.0 to 4.9 seconds |
| Linearity Range | 1.8 AU (5%) |
| Baseline Noise | ≤ ± 1 × 10-5 AU |
| Wavelength Range | 190 nm to 700 nm |
| Baseline Drift | ≤ 2.0 × 10-4 AU/h |
| Minimum Detectable Concentration | 4.0 × 10-9 g/mL (Naphthalene in Methanol) |
| Detector Cell Optical Path Length | 10 mm |
| Detector Cell Volume | 10 μl |
| Power Supply | AC 110 V-220 V ± 10%, 50-60 Hz |
| Dimensions | 600 × 440 × 380 mm |
| Packaging Dimensions | 600 × 410 × 300 mm × 2 |
| Weight | 54 kg |
Features
Optional Accessories
Sample injector HPLC column (5 µm, ID 6 × 200 mm) Workstation Value mounting frame Isocratic system kit
Applications
High Performance Liquid Chromatography is used for chemical analysis and in various applications, including pharmaceutical testing, food safety assessments, and environmental monitoring.
Frequently asked questions For High Performance Liquid Chromatography (HPLC)
1. What is an HPLC system used for?
Our HPLC systems are used to separate and analyze mixtures of substances. They are commonly used in pharmaceutical laboratories, food safety testing, medical diagnostics, and research institutions.
2. Does Labotronics offer HPLC systems for routine laboratory testing?
Yes, Labotronics offers HPLC systems that are suitable for both routine testing and more advanced applications. They are designed to deliver consistent and accurate results.
3. What makes Labotronics HPLC systems reliable?
Our systems are built with high-quality pumps and advanced flow control features to ensure stability and performance throughout testing.
4. What are the main applications of Labotronics HPLC?
Labotronics HPLC systems are ideal for analyzing pharmaceuticals, food products, environmental samples, and chemical formulations.
5. Can I use this for academic or research purposes?
Absolutely. Many academic institutions and research laboratories use Labotronics HPLC systems for experimental analysis and teaching purposes.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Pump Type | Double plunger reciprocating pump (Binary high-pressure gradient pump, 2 sets) |
| Flow Range | 0.001 mL/min to 10.000 mL/min |
| Setting Step Size | 0.001 mL/min |
| Flow Accuracy | ≤ ± 0.3 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.1 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Pump Type | Low-Pressure Quaternary Constant Flow Pump |
| Pump Flow Rate | 0.001 to 10.000 mL/min (step 0.001 mL/min) |
| Gradient Accuracy | ≤ ±1% |
| Retention Time Repeatability | ≤ 0.1% |
| Maximum Working Pressure | 63 MPa |
| Pump Type | Quaternary low-pressure pump |
| Flow Rate Range | 0.001 to 10.000 mL/min, in 0.001 mL increments |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.06 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 63 MPa |
| Flow Range | 0.001 to 10.000 mL/min (step: 0.001 mL/min) |
| Temperature Range | 0 to 40°C |
| Flow Accuracy | ± 0.2% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Flow Precision | RSD ≤ 0.075% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Maximum Pressure | 45 MPa (0.001 to 5.000 mL/min) 20 MPa (5.001 to 10.000 mL/min) |
| Flow Range | 0.001 to 10.000 mL/min |
| Flow Rate Increment | 0.001 mL |
| Flow Accuracy | ≤ ± 0.2% (1.00 mL/min, H₂O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.06% (1.00 mL/min, H₂O, R.T., 8.5 MPa) |
| Maximum Pressure | 70 MPa |
| Pump Type | Isocratic Pump (1 Set) |
| Flow Rate Range | 0.001 mL/min to 10.000 mL/min |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 45 MPa |
| Pump Type | Quaternary low-pressure gradient pump (1 Set) |
| Flow Rate Range | 0.001 mL/min to 10.000 mL/min |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 45 MPa |