$ 22325
Download CatalogSpecifications
| Pump Type | Low-Pressure Quaternary Constant Flow Pump |
| Pump Flow Rate | 0.001 to 10.000 mL/min (step 0.001 mL/min) |
| Gradient Accuracy | ≤ ±1% |
| Retention Time Repeatability | ≤ 0.1% |
| Maximum Working Pressure | 63 MPa |
| Communication Method | UDP Network Communication |
| Mixed Volume | 7500 µL |
| Detector | Diode Array Detector |
| Detector Linear | 2.0 AU |
| Wavelength Range | 190 to 700 nm |
| Noise | ≤ ± 0.5×10-5 AU |
| Drift | ≤ 1.0 × 10-4 AU/h |
| Analytical Cell | Optical path 10 mm Volume of 11µL |
| Semi-Prep Scale Cell | Optical path 2 mm Volume of 6 µL |
| Sampler Injector | Rheodyne 7725i |
| Column | Supersil ODS2 5µm ID 4.6 × 200mm |
| Workstation | Kromstation |
| Pump Power Consumption | 100 W |
| Detector Power Consumption | 100 W |
| Pump Power Supply | AC 220 V ± 10%, 50 Hz |
| Detector Power Supply | AC 220V ± 10%, 50 Hz |
| Power Supply | AC220V ± 10%, 50 Hz |
| Pump Dimensions (L × W × H) | 400 × 300 × 180 mm |
| Detector Dimensions (L × W × H) | 420 × 300 × 175 mm |
| Packaging Dimensions (W×D×H) | 600 × 440 × 380mm (2) 320 × 190 × 230 mm (1) |
| Pump Net Weight | 15 kg |
| Detector Net Weight | 16 kg |
| Gross Weight | 34 kg |
Features
Standard Accessories
Pump With MixerOptional Accessories
Column OvenApplications
High Performance Liquid Chromatography is widely used for the precise separation and analysis of compounds in various fields such as pharmaceuticals, environmental monitoring, food safety, and clinical diagnostics.
Frequently asked questions For High Performance Liquid Chromatography (HPLC)
1. What is an HPLC system used for?
Our HPLC systems are used to separate and analyze mixtures of substances. They are commonly used in pharmaceutical laboratories, food safety testing, medical diagnostics, and research institutions.
2. Does Labotronics offer HPLC systems for routine laboratory testing?
Yes, Labotronics offers HPLC systems that are suitable for both routine testing and more advanced applications. They are designed to deliver consistent and accurate results.
3. What makes Labotronics HPLC systems reliable?
Our systems are built with high-quality pumps and advanced flow control features to ensure stability and performance throughout testing.
4. What are the main applications of Labotronics HPLC?
Labotronics HPLC systems are ideal for analyzing pharmaceuticals, food products, environmental samples, and chemical formulations.
5. Can I use this for academic or research purposes?
Absolutely. Many academic institutions and research laboratories use Labotronics HPLC systems for experimental analysis and teaching purposes.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Pump Type | Quaternary low-pressure pump |
| Flow Rate Range | 0.001 to 10.000 mL/min, in 0.001 mL increments |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.06 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 63 MPa |
| Pump Type | Quaternary Low-Pressure Constant Flow Pump |
| Flow Rate Range | 0.001 to 10.0 mL/min (0.001 mL/min increments) |
| Flow Accuracy | ≤ ±0.3% |
| Flow Precision | ≤ 0.06% RSD |
| Maximum Pressure | 70 MPa (10,150 psi) |
| Flow Range | 0.001 to 10.000 mL/min |
| Flow Rate Increment | 0.001 mL/min |
| Flow Accuracy | ≤ ± 0.3% (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.1% (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 42 MPa |
| Pump Type | Quaternary low-pressure gradient pump (1 Set) |
| Flow Rate Range | 0.001 mL/min to 10.000 mL/min |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 45 MPa |
| Flow Range | 0.001 to 10.000 mL/min (step: 0.001 mL/min) |
| Temperature Range | 0 to 40°C |
| Flow Accuracy | ± 0.2% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Flow Precision | RSD ≤ 0.075% (1.0 mL/min, 8 ± 2 MPa, water, ambient temperature) |
| Maximum Pressure | 45 MPa (0.001 to 5.000 mL/min) 20 MPa (5.001 to 10.000 mL/min) |
| Pump Type | Double plunger reciprocating pump (Binary high-pressure gradient pump, 2 sets) |
| Flow Range | 0.001 mL/min to 10.000 mL/min |
| Setting Step Size | 0.001 mL/min |
| Flow Accuracy | ≤ ± 0.3 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.1 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Range | 0.001 to 10.000 mL/min |
| Flow Rate Increment | 0.001 mL |
| Flow Accuracy | ≤ ± 0.2% (1.00 mL/min, H₂O, R.T., 8.5 MPa) |
| Flow Stability | RSD ≤ 0.06% (1.00 mL/min, H₂O, R.T., 8.5 MPa) |
| Maximum Pressure | 70 MPa |
| Pump Type | Isocratic Pump (1 Set) |
| Flow Rate Range | 0.001 mL/min to 10.000 mL/min |
| Flow Accuracy | ≤ ± 0.2 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Flow Precision | RSD ≤ 0.075 % (1.00 mL/min, H2O, R.T., 8.5 MPa) |
| Maximum Pressure | 45 MPa |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534