Ion Chromatography LB-15ICG handles analytical workflows under a maximum operating pressure of 42 MPa (6000 psi) for reliable ionic separation. Its monolithic chassis architecture integrates internal pipelines to reduce system volume and improve flow efficiency. Chemically resistant PEEK-based pathways support broad pH operation while maintaining solvent compatibility. Embedded eluent generation with multi-stage vacuum degassing stabilizes flow and enhances detection consistency. It is developed to deliver dependable analytical outcomes through compact construction and automated system control.
$ 29031.25
Download CatalogSpecifications
| Maximum pressure | 42 MPa / 6000 Psi |
| Flow range | 0.001 to 10.000 mL/min |
| Flow accuracy | ≤0.1% |
| Flow repeatability | RSD ≤0.01% |
| Pressure fluctuation | ≤0.5% |
| Flow increment | ≤0.001 mL/min |
| Materials | quartz plunger, high-pressure seals, PEEK pump head; acid/alkali/organic solvent resistant and durable. |
| Over pressure protection | automatic alarm and shutdown when pressure exceeds preset limit. |
| Electrically Controlled Auto Sampling Valve head material | PEEK |
| Lifetime | ≥100,000 switching cycles |
| Anion Column | High-capacity anion separation column capable of analyzing F⁻, Cl⁻, Br⁻, NO₂⁻, NO₃⁻, SO₄²⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻, dichloroacetic acid, trichloroacetic acid, formate, acetate, oxalate, etc. |
| Cation Column | High-capacity cation separation column capable of analyzing Li⁺, Na⁺, K⁺, NH₄⁺, Ca²⁺, Mg²⁺, methylamine, dimethylamine, trimethylamine, etc. |
| Maximum pressure of Anion and Cation Column | ≥3000 psi |
| Flow rate of Anion and Cation Column | ≥2.0 mL/min |
| Suppressor | Factory-produced electrolytic continuously regenerated suppressor, no external regenerant or pumps required. |
| Suppression capacity | ≥100 μeq/min |
| Dead volume | ≤50 μL |
| Conductivity Detector | high-sensitivity, large-capacity bipolar conductivity detector with wider detection range |
| Temperature compensation of Conductivity Detector | ambient +5°C to 80°C |
| Max pressure tolerance of Conductivity Detector | ≥8 MPa |
| Temperature control accuracy of Conductivity Detector | ±0.1°C |
| Baseline noise of Conductivity Detector | ≤0.5% FS |
| Baseline drift of Conductivity Detector | ≤10.0% FS / 30 min |
| Minimum detection limit of Conductivity Detector | Cl⁻ ≤0.0005 μg/mL; Li⁺ ≤0.0005 μg/mL |
| Qualitative repeatability of Conductivity Detector | ≤0.5% |
| Quantitative repeatability of Conductivity Detector | ≤1% |
| Temperature Control System | Dual-isolation, internal circulation, high-precision temperature control system with independent column oven and shared oven for detector and suppressor, ensuring high stability. |
| Power consumption | 1200 W |
| Power supply | 220 V 50 Hz |
| Dimension (W × D × H) | 518 × 422 × 768 mm |
| Packaging dimension (W × D × H) | 600 × 500 × 800 mm |
| Net weight | 52 kg |
| Gross weight | 62 kg |
Features
Programmable auto shutdown
Pump chamber rinsing
One-touch startup
Leak detection safety
Optional Accessories
| Accessory | Quantity |
| Anion column | 1 set |
| Cation Column | 1 set |
| Four-stage online degassing | 1 set |
| Autosampler 120 wells | 1 set |
| Anion eluent | 1 set |
| MSA Built-in Eluent Generator | 1 set |
Applications
Ion Chromatography LB-15ICG is used for simultaneous determination of anions and cations in environmental monitoring laboratories, pharmaceutical quality control, food and beverage testing facilities, chemical research institutes, and academic or industrial analytical laboratories requiring precise ionic measurement.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Dimensions (L x W x H) | 350 x 470 x 650 mm |
| Weight | 34 kgs |
| Whole plastic pipeline | Made of PEEK material |
| Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically |
| Dimensions (L x W x H) | 350 x 470 x 510 mm |
| Weight | 26 kgs |
| Whole plastic pipeline | Made of PEEK material |
| Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically. |
| Dimensions (L x W x H) | 325 x 400 x 500 mm |
| Weight | 21 kgs |
| Whole plastic pipeline | Made of PEEK material |
| Six way valve | PEEK material FLOM series of six way valve, pressure 5000 psi, a signal automatic collecting and flow function |
| Dimensions (L x W x H) | 500 x 570 x 510 mm |
| Weight | 40 kgs |
| Whole plastic pipeline | Made of PEEK material |
| Six way valve | Rheodyne electromagnetic six-way valve, compression resistance of 7000 psi, collect signals automatically. |
| IC Pump Type | High-pressure and low-pulse two-piston tandem advection pump |
| IC Pump Maximum Pressure | 35 MPa (PEEK) |
| IC Pump Pressure Display Accuracy | ≤ 0.1Mpa |
| IC Pump Flow Stability | (0.2 to 0.5) mL/min ≤3 % (0.5 to 1.0) mL/min ≤2 % >1.0mL/min ≤ 2 % |
| IC Pump Allowable Deviation of Flow | (0.2 to 0.5) mL/min , ±5% (0.5 to 1.0) mL/min, ±3% >1.0 mL/min, ±2% |