Polarimeter LB-13POM

Polarimeter LB-13POM

Polarimeter LB-13POM offers a measurement range of ±89.99° for optical rotation and up to ±259°Z for sugar content, enabling precise analysis. It maintains a temperature control range of 15 to 45℃ for stable and reliable performance. It features a fully automated, highly integrated control system for easy and convenient operation. Our polarimeter is equipped with a 7-inch TFT true color touch screen for clear display and user-friendly control.

$ 17712.5

Download Catalog

Specifications

Measurement Range Optical rotation: ± 89.99°
Sugar content: ± 259°Z
Measurement Accuracy ± 0.01° (− 45° ≤ optical rotation ≤ + 45°)
±0.02° (optical rotation < −45° or > +45°)
Temperature Control Range 15℃ to 45℃
Minimum Reading 0.001° (optical rotation)
Working Wavelength 589.3 nm
Repeatability 0.002° (optical rotation)
Light Transmittance 0.10%
Light Source LED
Data Storage 1000 groups
Communication Interface USB, RS232
Display 7-inch TFT true color touch screen
Power Consumption 250W
Net Weight 24 kg

Features

  • Durable LED lamp

  • Peltier temperature control

  • Automatic Calibration

  • Wide measurement range

  • Multi-mode measurement 

Applications

Polarimeter LB-13POM is used to measure the optical rotation of substances to determine their concentration, purity, and specific rotation. It is widely used in pharmaceuticals, food and beverage, chemical industries, and research laboratories.

Get Quote

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Polarimeter

Polarimeter LB-10POM

Measurement Range Optical rotation: ± 89.99°
Sugar content: ± 257°Z
Accuracy ± 0.01° (− 45° ≤ optical rotation ≤ + 45°)
± 0.02° (at < −45° or > +45°)
Minimum Reading 0.001 (rotation)
Temperature Display Range 0 to 100°C
Working Wavelength 589.3 nm

$ 3237.5

Manual Polarimeter LB-20POM

Measuring Range ±180°
Optical Wavelength 589 nm
Resolution 0.05°
Magnifier 3X
Scale Value 1°

$ 1450

Polarimeter LB-11POM
Measurement Range Optical rotation: ±89.99°
Sugar content: ±259°Z
Accuracy ±0.01° (−45° ≤ optical rotation ≤ +45°)
±0.02° (optical rotation < −45° or > +45°)
Temperature Control Range 15℃ to 45℃
Temperature Control Accuracy ± 0.2℃
Minimum Reading 0.001° (optical rotation)

$ 8450

Polarimeter LB-12POM
Measurement Range Optical rotation: ± 89.99°
Sugar content: ± 259°Z
Measurement Accuracy ± 0.01° (– 45° ≤ optical rotation ≤ + 45°)
± 0.02° (optical rotation < – 45° or > + 45°)
Temperature Control Range 15℃ to 35℃
Temperature Control Accuracy ± 0.2℃
Minimum Reading 0.001° (optical rotation)

$ 8475