CO2 Incubator LB-12COI offers an 85L capacity and operates efficiently from 4°C to 60°C, ensuring precise incubation of sensitive cultures. It is equipped with HEPA filters, maintaining a clean and safe culture environment. It features an infrared (IR) CO2 sensor for accurate and stable CO2 monitoring. Our incubator has an LCD touchscreen for intuitive controls, enabling reliable management of operational and culture conditions.
$ 9400
Download CatalogSpecifications
| Capacity | 85 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Working Temperature Range | 10°C to 30°C |
| Relative Humidity | Up to 95% RH at 37°C |
| CO2 Control Range | 0 to 20% |
| CO2 Supply | 0.05 to 0.1 MPa |
| CO2 Concentration Recovery Time | ≤5 Min (door opened for 30 seconds, set value 5%) |
| CO2 Measurement Principle | Infrared (IR) detection |
| CO2 Display Resolution | 0.1% |
| Timing Function | 0 to 999.9 hours |
| Sterilization Method | 180°C High heat sterilization |
| Filtration | HEPA (ISO Class 5), effective within 5 minutes |
| Display | 5-Inch LCD Touchscreen |
| Scalability | Stackable up to 2 units |
| User Management | 3 levels of user access (Administrator / Tester / Operator) |
| Historical Data Storage | 250,000 messages |
| Data Export Interface | USB interface |
| Power Consumption | 500 W |
| Power Supply | 115/230V ±10%, 50/60Hz |
| Internal Dimension (W × D × H) | 440 × 400 × 500 mm |
| External Dimension (W × D × H) | 560 × 530 × 825 mm |
| Packaging Dimension (W × D × H) | 700 × 645 × 940 mm |
| Net Weight | 78 kg |
| Gross Weight | 98 kg |
Features
High-heat sterilization
Multi-directional heating
Detachable shelves and humidity pan
Historical data tracking
USB data export
User-friendly interface
Audible and visual alarms
Applications
CO2 Incubator LB-12COI is used for precise cultivation of cells, tissues, and microorganisms under controlled temperature and CO2 levels. It is widely used in biomedical research, clinical laboratories, pharmaceutical development, and biotechnology applications.
Frequently asked questions For CO2 Incubator
1. What makes the LB-12COI CO2 Incubator more suitable for cell culture than a standard incubator?
Labotronics' LB-12COI CO2 Incubator maintains precise temperature and CO? levels essential for mammalian cell growth. Unlike standard incubators, it creates a stable environment that mimics in vivo conditions, making it ideal for sensitive applications such as cell culture, IVF, and biomedical research.
2. Is the LB-12COI suitable for IVF or stem cell research?
Yes, the LB-12COI’s precise temperature and CO2 regulation, along with its sterile HEPA-filtered environment, make it suitable for sensitive applications like in vitro fertilization (IVF), stem cell culture, and regenerative medicine research.
3. What type of CO2 cylinder should be used with the LB-12COI CO? Incubator?
The LB-12COI CO2 Incubator requires a food-grade or medical-grade CO? cylinder with a pressure regulator that maintains a supply pressure between 0.05 to 0.1 MPa. Always use CO? cylinders fitted with two-stage regulators to ensure stable gas delivery.
4. How does the LB-12COI support good laboratory practice (GLP)?
Labotronics LB-12COI supports GLP through data traceability, user access levels, and USB export of stored logs. These features help labs maintain audit trails, manage access securely, and ensure reproducible results.
5. What is a CO2 incubator and why is it important in biological research?
A CO2incubator is a laboratory device used to cultivate cells under controlled environmental conditions. It maintains stable temperature, humidity, and carbon dioxide levels to create an optimal environment for cell growth.
6. How is a CO2 incubator different from a standard laboratory incubator?
Unlike standard incubators that only control temperature, CO2 incubators regulate CO2concentration and humidity, making them suitable for mammalian cells and pH-sensitive media.
7. What types of samples or cultures can be grown in a CO2 incubator?
CO? incubators are suitable for growing mammalian cells, stem cells, cancer cells, embryos (IVF), and engineered tissues. Our models are widely used in clinical labs, biotech companies, and academic research facilities due to their reliability and performance.
8. Why is HEPA filtration important in CO2 incubators?
A HEPA filter removes airborne contaminants such as bacteria, dust, and mold spores, ensuring a sterile culture environment. Labotronics incubators feature ISO Class 5 HEPA filtration, which effectively purifies chamber air within minutes, minimizing contamination risks in long-term cultures.
9. Can CO2 incubators support anaerobic or hypoxic environments?
Yes, Labotronics advanced CO2incubators allow oxygen control and nitrogen gas integration to create hypoxic or anaerobic conditions, ideal for cancer biology, hypoxia studies, and low-O2 stem cell cultures, where precise gas regulation is essential.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Capacity | 40 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 120 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 160 L |
| Temperature Range | RT+5℃ to 60℃ |
| CO2 Range | 0 to 20% |
| Convection Mode | Forced Convection |
| CO2 Sensor/Uniformity | IR sensor (±0.1%) |
| Capacity | 40 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Fluctuation | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 185L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 260 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.4 ℃ |
| Capacity | 248 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 185 L |
| Temperature Range | 4°C to 60°C |
| Temperature Uniformity | ±0.2°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 260 L |
| Temperature Range | 20 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.4 °C (at 37 °C / RT 20 °C) |
| Capacity | 120 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ (at 37 ℃ / RT 20 ℃) |
| Capacity | 80L |
| Temperature Range | 5℃ to 60℃ |
| Temperature Accuracy | 0.1℃ |
| Temperature Fluctuation | ±0.3℃ (at 37℃) |
| Temperature Uniformity (at 37℃) | ±0.5℃ (at 37℃) |
| Capacity | 180 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
| Capacity | 180 L |
| Temperature Range | 5 ℃ to 60 ℃ |
| Temperature Accuracy | 0.1 ℃ |
| Temperature Stability | ± 0.1 ℃ (at 37 ℃) |
| Temperature Uniformity | ± 0.3 ℃ |
| Capacity | 85 L |
| Temperature Range | 5°C to 60°C |
| Temperature Uniformity | ±0.3°C at 37°C |
| Temperature Resolution | 0.1°C |
| Temperature Recovery Time | ≤ 10 min (door opened for 30 seconds, room temperature 25°C, set value 37°C) |
| Capacity | 40 L |
| Temperature Range | 5 °C to 60 °C |
| Temperature Accuracy | 0.1 °C |
| Temperature Stability | ± 0.1 °C (at 37 °C) |
| Temperature Uniformity | ± 0.3 °C (at 37 °C / RT 20 °C) |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com