$ 17137.5
Download CatalogSpecifications
| Section thickness range (adjustable) | 1 µm ~ 80 µm |
| Retraction range ( adjustable ) | 0 µm ~ 80 µm ( 5 µm increment ) |
| Horizontal specimen stroke | 20 mm |
| Vertical specimen stroke | 60 mm |
| Maximum specimen size | 35 mm × 35 mm |
| Coarse feeding speed | 0.7 mm/s 0.35 mm/s |
| Chamber temperature range | -10 °C to -30 °C |
| Peltier lowest temperature | -55 °C |
| Peltier working time | 15 minutes |
| Freezing shelf minimum temperature | -45 °C |
| Cool down time (-30 °C) | 60 minutes |
| Setting values | 1 µm ~ 20 µm ( 1 µm increment ) 20 µm ~ 40 µm ( 2 µm increment ) 40 µm ~ 80 µm ( 5 µm increment ) |
| Trimming thickness range ( adjustable ) | 10 µm ~ 400 µm 10 µm ~ 50 µm ( 5 µm increment ) 50 µm ~ 100 µm ( 10 µm increment ) 100 µm ~ 400 µm ( 50 µm increment ) |
| Voltage | AC 220 V ± 10 % ; 50 Hz |
| Power | 850 W |
| Dimensions | 660 × 640 × 1130 mm |
| Weight | 130 kgs |
Features
Applications
Used in engineering, medicine, pathology, histology, botany laboratories, research institutes, etc.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Section Thickness Range | 0.5 μm to 100 μm (3 to 5 μm is optimal) |
| Section Thickness Setting | 0.5 to 5 μm, in 0.5 μm increments 5 to 20 μm, in 1 μm increments 20 to 60 μm, in 5 μm increments 60 to 100 μm, in 10 μm increments |
| Trimming Thickness | 1 to 600 μm |
| Trimming Thickness Setting | 1 to 10 μm, in 1 μm increments 10 to 20 μm, in 2 μm increments 20 to 50 μm, in 5 μm increments 50 to 100 μm, in 10 μm increments 100 to 600 μm, in 50 μm increments |
| Specimen Retraction | 10 to 150 μm (can be disabled), in 1 μm increments |
| Temperature Range | -5°C to -50°C, Default: -15°C |
| Sectioning Thickness Range | 0.5 to 100 μm, Default: 6 µm |
| Section Thickness Setting | 0.5 to 5 µm, Step: 0.5 µm 5 to 20 µm, Step: 1 µm 20 to 60 µm, Step: 5 µm 60 to 100 µm, Step: 10 µm |
| Trim Thickness Range | 1 to 600 μm, Default: 20 µm |
| Trim Thickness Setting | 1 to 600 µm, Default: 20 µm 1 to 600 µm, Step: 20 µm 20 to 50 µm, Step: 5 µm 50 to 100 µm, Step: 10 µm 100 to 600 µm, Step: 50 µm |
| Slice Thickness Range | 0.5μm to 100μm (Optimal: 3 to 5μm) |
| Section Thickness Setting | 0.5 to 5μm in 0.5μm increments 5 to 20μm in 1μm increments 20 to 60μm in 5μm increments 60 to 100μm in 10μm increments |
| Trimming Section Range | 1 to 600μm |
| Trimming Thickness Setting | 1 to 10μm in 1μm increments 10 to 20μm in 2μm increments 20 to 50μm in 5μm increments 50 to 100μm in 10μm increments 100 to 600μm in 50μm increments |
| Maximal Slice Section | 50 × 45 mm |
| Section Thickness Range | 0 µm – 999.9 µm, adjustable increment: 0.1 µm |
| Trimming Thickness Range | 0 µm – 999.9 µm, adjustable increment: 0.1 µm, can be turned off |
| Tissue Retraction Function | 0 µm – 999.9 µm, adjustable increment: 0.1 µm |
| Horizontal Stroke | 30 mm |
| Vertical Stroke | 70 mm |
| Section Thickness Range | 1 μm to 100 μm |
| Freezing Chamber Temp. Range | -35℃ to 40℃ adjustable |
| Section Steps | 1 to 20 μm: 1 μm step 20 to 50 μm: 2 μm step 50 to 100 μm: 5 μm step |
| Section Thickness Deviation | ±20% |
| Trimming Thickness Range | 1 to 600 μm |
| Slice Thickness Range | 0μm to 60μm |
| Section Thickness Settings | 0 to 2μm: 0.5μm increments 2 to 10μm: 1μm increments 10 to 20μm: 2μm increments 20 to 60μm: 5μm increments |
| Horizontal Specimen Stroke | 20 mm |
| Vertical Specimen Stroke | 50 mm |
| Slip Precision | ±5% |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534