Cryostat Microtome LB-16CS

Cryostat Microtome LB-16CS

Cryostat Microtome LB-16CS offers a 0 to 60 μm slice thickness range for precise, accurate tissue sectioning. It provides 20 mm horizontal and 50 mm vertical specimen strokes for smooth, controlled slicing. Our microtome allows ±8° X/Y and 360° Z-axis adjustment for precise, high-quality sectioning. It features a top storage tray for easy access to blades, wax blocks, and consumables.

$ 4846.25

Download Catalog

Specifications

Slice Thickness Range 0μm to 60μm
Section Thickness Settings 0 to 2μm: 0.5μm increments
2 to 10μm: 1μm increments
10 to 20μm: 2μm increments
20 to 60μm: 5μm increments
Horizontal Specimen Stroke 20 mm
Vertical Specimen Stroke 50 mm
Slip Precision ±5%
Maximal Slice Section 50 × 45 mm
Specimen Adjustment Direction Horizontal: 8°, Vertical: 8°, Rotation: 360°
Blade Holder Base Movement Range Front/Back: ±25 mm
Left/Right: ±25 mm
Blade Holder Angle 0° to 10°
Dimension 500 × 480 × 280mm
Packing Dimension 520 × 520× 450mm
Net Weight 30kg
Gross Weight 41 kg

Features

  • Integrated Clipper-Built Case

  • Maintenance-Free Operation

  • 3-Axis Specimen Orientation

  • Advanced Blade Holder Design

  • Dual Safety Locking System

Standard Accessories

Accessory

Quantity

Disposable Blade Holder

1 pc

Specimen Cassette Clamp

1 pc

Hexagonal Wrench

1 set

Brush

1 pc

Optional Accessories

  • Base
  • Handwheel (Big)
  • Handwheel (Small)
  • Outshell
  • Pillar
  • Removable Part
  • Track
  • Bearing
  • Gear
  • Blade Holder
  • Specimen Clamp
  • Handwheel Bearing
  • Blade Holder Discreteness
  • Blade Holder Base
  • Dial
  • Adjust Pole
  • Steel Knife
     

Applications

Cryostat Microtome LB-16CS is used to prepare thin tissue sections at low temperatures and is widely used in Clinical Pathology Labs, Cancer Diagnosis Centers, Research Laboratories, Veterinary Clinics, Forensic Labs.

Cryostat Microtome LB-16CS Banner
Cryostat Microtome LB-16CS Banner

Get Quote

Still have questions?

If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!

Cryostat Microtome

Cryostat Microtome LB-12CS

Section Thickness Range 1 μm to 100 μm
Freezing Chamber Temp. Range -35℃ to 40℃ adjustable
Section Steps 1 to 20 μm: 1 μm step
20 to 50 μm: 2 μm step
50 to 100 μm: 5 μm step
Section Thickness Deviation ±20%
Trimming Thickness Range 1 to 600 μm

$ 16555

Cryostat Microtome LB-11CS

Section Thickness Range 0.5µm to 100µm adjustable
Section Thickness Increment Range 0.5µm to 5µm, in 0.5µm increment
5µm to 20µm, in 1µm increments
20µm to 50µm, in 2µm increments
50µm to 100µm, in 5µm increments
Trimming Thickness Range 1µm to 600µm adjustable
Trimming Thickness Increment Range 0µm to 50µm, in 5µm increments
50µm to 100µm, in 10µm increments
100µm to 600µm, in 50µm increments
Tissue Retraction Function 0µm to 100µm adjustable in 2µm increment

$ 17498.75

Cryostat Microtome LB-15CS
Slice Thickness Range 0.5μm to 100μm (Optimal: 3 to 5μm)
Section Thickness Setting 0.5 to 5μm in 0.5μm increments
5 to 20μm in 1μm increments
20 to 60μm in 5μm increments
60 to 100μm in 10μm increments
Trimming Section Range 1 to 600μm
Trimming Thickness Setting 1 to 10μm in 1μm increments
10 to 20μm in 2μm increments
20 to 50μm in 5μm increments
50 to 100μm in 10μm increments
100 to 600μm in 50μm increments
Maximal Slice Section 50 × 45 mm

$ 5362.5

Cryostat Microtome LB-10CS
Section thickness range (adjustable) 1 µm ~ 80 µm
Retraction range ( adjustable ) 0 µm ~ 80 µm ( 5 µm increment )
Horizontal specimen stroke 20 mm
Vertical specimen stroke 60 mm
Maximum specimen size 35 mm × 35 mm

$ 16987.5

Cryostat Microtome LB-14CS

Section Thickness Range 0.5 μm to 100 μm (3 to 5 μm is optimal)
Section Thickness Setting 0.5 to 5 μm, in 0.5 μm increments
5 to 20 μm, in 1 μm increments
20 to 60 μm, in 5 μm increments
60 to 100 μm, in 10 μm increments
Trimming Thickness 1 to 600 μm
Trimming Thickness Setting 1 to 10 μm, in 1 μm increments
10 to 20 μm, in 2 μm increments
20 to 50 μm, in 5 μm increments
50 to 100 μm, in 10 μm increments
100 to 600 μm, in 50 μm increments
Specimen Retraction 10 to 150 μm (can be disabled), in 1 μm increments

$ 8662.5

Cryostat Microtome LB-13CS

Temperature Range -5°C to -50°C, Default: -15°C
Sectioning Thickness Range 0.5 to 100 μm, Default: 6 µm
Section Thickness Setting 0.5 to 5 µm, Step: 0.5 µm
5 to 20 µm, Step: 1 µm
20 to 60 µm, Step: 5 µm
60 to 100 µm, Step: 10 µm
Trim Thickness Range 1 to 600 μm, Default: 20 µm
Trim Thickness Setting 1 to 600 µm, Default: 20 µm
1 to 600 µm, Step: 20 µm
20 to 50 µm, Step: 5 µm
50 to 100 µm, Step: 10 µm
100 to 600 µm, Step: 50 µm

$ 17307.5

0
×

Ask Quote

Need quick help? Chat with us on WhatsApp:

WhatsApp QR Code

OR

Copyright © Labotronics Scientific 2026