Cryostat Microtome LB-12CS offers a section thickness range of 1 to 100 μm for high-precision tissue slicing. Its freezing chamber temperature is adjustable from -35℃ to 40℃, ensuring optimal sample preservation and cutting conditions. Our microtome features UV sterilization for enhanced safety and a hygienic work environment. It also features an intuitive color LCD touchscreen interface offering easy operation and precise parameter adjustments.
$ 16555
Download CatalogSpecifications
| Section Thickness Range | 1 μm to 100 μm |
| Freezing Chamber Temp. Range | -35℃ to 40℃ adjustable |
| Section Steps | 1 to 20 μm: 1 μm step 20 to 50 μm: 2 μm step 50 to 100 μm: 5 μm step |
| Section Thickness Deviation | ±20% |
| Trimming Thickness Range | 1 to 600 μm |
| Trimming Steps | 1 to 50 μm: 5 μm step 50 to 100 μm: 10 μm step 100 to 600 μm: 50 μm step |
| Defrost Mode | Manual / Auto |
| Refrigerating Capacity | 690 W |
| Refrigerant | R449A / 400g ±5g |
| Quick-Freeze Shelf Operating Temperature | -40℃ to 40℃ |
| Quick-Freeze Shelf Minimum Reaching Temperature | -60℃ (±5℃) |
| Specimen Holder Freezing Points | 18 |
| Semiconductor Freezing Points | 2 |
| Sample Retraction | 0 to 200 μm adjustable, 5 μm steps |
| Horizontal Stroke | 25 mm ±1 mm |
| Vertical Stroke | 59 mm ±0.5 mm |
| Max Specimen Size | 55 mm × 55 mm |
| Clamp Adjustment Angles | X and Y axis: ±12°, Z axis: 360° |
| Movement Speeds Slow Forward/Rewind | 300 μm/s |
| Movement Speeds Fast Forward/Rewind | 900 μm/s |
| Main Fuse | 4A |
| Power Supply | 220 to 240VAC, 50Hz / 60Hz; 110 to 127VAC, 60Hz |
| Power Consumption | 220 to 240VAC: 1400VA; 110 to 127VAC: 1200VA |
| Dimension (L×W×H) | 780 mm (650 mm without handwheel) × 700 mm × 1280 mm ±5% |
| Packing Dimension | 913 × 804 × 1467 mm |
| Net Weight | 120 kg |
| Gross Weight | 208±10kg |
Features
Automatic/manual hibernation mode
Semiconductor refrigeration system
Slice count and thickness calculation
Adjustable specimen clamp movement speed
One-piece injection-molded outer shell
Anti-fog heated viewing glass
Standard Accessories
Accessory | Quantity |
Specimen Disc | 10 pcs |
Fuse (4A) | 2 pcs |
Appliance Stand | 1 pc |
Power Line | 1 line |
Hexagonal Wrench | 1 set |
Brush | 1 pc |
Handle | 1 pc |
Applications
Cryostat Microtome LB-12CS is used to prepare thin tissue sections at low temperatures and is widely used in Clinical Pathology Labs, Cancer Diagnosis Centers, Research Laboratories, Veterinary Clinics, Forensic Labs.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Section thickness range (adjustable) | 1 µm ~ 80 µm |
| Retraction range ( adjustable ) | 0 µm ~ 80 µm ( 5 µm increment ) |
| Horizontal specimen stroke | 20 mm |
| Vertical specimen stroke | 60 mm |
| Maximum specimen size | 35 mm × 35 mm |
| Temperature Range | -5°C to -50°C, Default: -15°C |
| Sectioning Thickness Range | 0.5 to 100 μm, Default: 6 µm |
| Section Thickness Setting | 0.5 to 5 µm, Step: 0.5 µm 5 to 20 µm, Step: 1 µm 20 to 60 µm, Step: 5 µm 60 to 100 µm, Step: 10 µm |
| Trim Thickness Range | 1 to 600 μm, Default: 20 µm |
| Trim Thickness Setting | 1 to 600 µm, Default: 20 µm 1 to 600 µm, Step: 20 µm 20 to 50 µm, Step: 5 µm 50 to 100 µm, Step: 10 µm 100 to 600 µm, Step: 50 µm |
| Section Thickness Range | 0.5µm to 100µm adjustable |
| Section Thickness Increment Range | 0.5µm to 5µm, in 0.5µm increment 5µm to 20µm, in 1µm increments 20µm to 50µm, in 2µm increments 50µm to 100µm, in 5µm increments |
| Trimming Thickness Range | 1µm to 600µm adjustable |
| Trimming Thickness Increment Range | 0µm to 50µm, in 5µm increments 50µm to 100µm, in 10µm increments 100µm to 600µm, in 50µm increments |
| Tissue Retraction Function | 0µm to 100µm adjustable in 2µm increment |
| Slice Thickness Range | 0μm to 60μm |
| Section Thickness Settings | 0 to 2μm: 0.5μm increments 2 to 10μm: 1μm increments 10 to 20μm: 2μm increments 20 to 60μm: 5μm increments |
| Horizontal Specimen Stroke | 20 mm |
| Vertical Specimen Stroke | 50 mm |
| Slip Precision | ±5% |
| Section Thickness Range | 0.5 μm to 100 μm (3 to 5 μm is optimal) |
| Section Thickness Setting | 0.5 to 5 μm, in 0.5 μm increments 5 to 20 μm, in 1 μm increments 20 to 60 μm, in 5 μm increments 60 to 100 μm, in 10 μm increments |
| Trimming Thickness | 1 to 600 μm |
| Trimming Thickness Setting | 1 to 10 μm, in 1 μm increments 10 to 20 μm, in 2 μm increments 20 to 50 μm, in 5 μm increments 50 to 100 μm, in 10 μm increments 100 to 600 μm, in 50 μm increments |
| Specimen Retraction | 10 to 150 μm (can be disabled), in 1 μm increments |
| Slice Thickness Range | 0.5μm to 100μm (Optimal: 3 to 5μm) |
| Section Thickness Setting | 0.5 to 5μm in 0.5μm increments 5 to 20μm in 1μm increments 20 to 60μm in 5μm increments 60 to 100μm in 10μm increments |
| Trimming Section Range | 1 to 600μm |
| Trimming Thickness Setting | 1 to 10μm in 1μm increments 10 to 20μm in 2μm increments 20 to 50μm in 5μm increments 50 to 100μm in 10μm increments 100 to 600μm in 50μm increments |
| Maximal Slice Section | 50 × 45 mm |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com