Cryostat Microtome LB-15CS offers a slice thickness range of 0.5μm to 100 μm for high-precision sections. It also supports a trimming section range of 1 to 600μm, allowing flexible and efficient sample preparation across various tissue types. It features a large-capacity waste tray that is easy to remove, ensuring a clean and hygienic workspace. Its user-friendly LCD interface with an English menu allows easy and precise slicing and trimming adjustments.
$ 5362.5
Download CatalogSpecifications
| Slice Thickness Range | 0.5μm to 100μm (Optimal: 3 to 5μm) |
| Section Thickness Setting | 0.5 to 5μm in 0.5μm increments 5 to 20μm in 1μm increments 20 to 60μm in 5μm increments 60 to 100μm in 10μm increments |
| Trimming Section Range | 1 to 600μm |
| Trimming Thickness Setting | 1 to 10μm in 1μm increments 10 to 20μm in 2μm increments 20 to 50μm in 5μm increments 50 to 100μm in 10μm increments 100 to 600μm in 50μm increments |
| Maximal Slice Section | 50 × 45 mm |
| Horizontal Specimen Stroke | 20 mm |
| Vertical Specimen Stroke | 55 mm |
| Specimen Retraction | 20 μm |
| Slip Precision | ± 5% |
| Dimension (L × W × H) | 500 × 450 × 300 mm |
| Dimensions | 520 × 520 × 450mm |
| Net Weight | 32 kg |
| Gross Weight | 43 kg |
Features
Precision stepper motor drive
Smart specimen retraction
Auto trimming with half-cut detection
Dual trimming options
Versatile two-in-one knife holder
Handwheel safety lock
Automatic reset function
Standard Accessories
Accessory | Quantity |
Disposable Blade Holder | 1 pc |
Specimen Cassette | 1 pc |
Fuse (2A) | 2 pcs |
Power Line | 1 line |
Hexagonal Wrench | 1 set |
Brush | 1 pc |
Optional Accessories
Applications
Cryostat Microtome LB-15CS is used to prepare thin tissue sections at low temperatures and is widely used in Clinical Pathology Labs, Cancer Diagnosis Centers, Research Laboratories, Veterinary Clinics, Forensic Labs.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Slice Thickness Range | 0μm to 60μm |
| Section Thickness Settings | 0 to 2μm: 0.5μm increments 2 to 10μm: 1μm increments 10 to 20μm: 2μm increments 20 to 60μm: 5μm increments |
| Horizontal Specimen Stroke | 20 mm |
| Vertical Specimen Stroke | 50 mm |
| Slip Precision | ±5% |
| Section Thickness Range | 0.5µm to 100µm adjustable |
| Section Thickness Increment Range | 0.5µm to 5µm, in 0.5µm increment 5µm to 20µm, in 1µm increments 20µm to 50µm, in 2µm increments 50µm to 100µm, in 5µm increments |
| Trimming Thickness Range | 1µm to 600µm adjustable |
| Trimming Thickness Increment Range | 0µm to 50µm, in 5µm increments 50µm to 100µm, in 10µm increments 100µm to 600µm, in 50µm increments |
| Tissue Retraction Function | 0µm to 100µm adjustable in 2µm increment |
| Section Thickness Range | 1 μm to 100 μm |
| Freezing Chamber Temp. Range | -35℃ to 40℃ adjustable |
| Section Steps | 1 to 20 μm: 1 μm step 20 to 50 μm: 2 μm step 50 to 100 μm: 5 μm step |
| Section Thickness Deviation | ±20% |
| Trimming Thickness Range | 1 to 600 μm |
| Section thickness range (adjustable) | 1 µm ~ 80 µm |
| Retraction range ( adjustable ) | 0 µm ~ 80 µm ( 5 µm increment ) |
| Horizontal specimen stroke | 20 mm |
| Vertical specimen stroke | 60 mm |
| Maximum specimen size | 35 mm × 35 mm |
| Temperature Range | -5°C to -50°C, Default: -15°C |
| Sectioning Thickness Range | 0.5 to 100 μm, Default: 6 µm |
| Section Thickness Setting | 0.5 to 5 µm, Step: 0.5 µm 5 to 20 µm, Step: 1 µm 20 to 60 µm, Step: 5 µm 60 to 100 µm, Step: 10 µm |
| Trim Thickness Range | 1 to 600 μm, Default: 20 µm |
| Trim Thickness Setting | 1 to 600 µm, Default: 20 µm 1 to 600 µm, Step: 20 µm 20 to 50 µm, Step: 5 µm 50 to 100 µm, Step: 10 µm 100 to 600 µm, Step: 50 µm |
| Section Thickness Range | 0.5 μm to 100 μm (3 to 5 μm is optimal) |
| Section Thickness Setting | 0.5 to 5 μm, in 0.5 μm increments 5 to 20 μm, in 1 μm increments 20 to 60 μm, in 5 μm increments 60 to 100 μm, in 10 μm increments |
| Trimming Thickness | 1 to 600 μm |
| Trimming Thickness Setting | 1 to 10 μm, in 1 μm increments 10 to 20 μm, in 2 μm increments 20 to 50 μm, in 5 μm increments 50 to 100 μm, in 10 μm increments 100 to 600 μm, in 50 μm increments |
| Specimen Retraction | 10 to 150 μm (can be disabled), in 1 μm increments |