Dry Bath Incubator LB-60DBI features a single-block capacity and operates within a temperature range of 5 °C to 160 °C. It is equipped with microprocessor control for precise temperature regulation. It uses a high-purity aluminium block, ensuring uniform and efficient heat conduction. Our dry bath incubator includes a clear digital display, providing real-time monitoring of operational parameters.
Get Quote Download Catalog Download ManualSpecifications
Block capacity | 1 block |
Temperature Range | 5 °C to 160 °C |
Temperature Accuracy | ± 0.5°C (at 40 °C) ±1°C (at 120 °C) |
Temperature Display Accuracy | 0.1℃ |
Block Temperature Uniformity | ± 0.5°C |
Heating Rate | ≤15min( 25℃ to 160℃) |
Time Range | 1 min to 99 hrs 59 mins / ∞ (continuous operation) |
Power Consumption | 300 W |
Power Supply | AC220/110V 50/60Hz |
Dimensions (W × D × H) | 260 × 220 × 100 mm |
Weight | 5 kg |
Features
Over-temperature protection
Automatic fault detection
Adjustable timer function
Interchangeable block system
Temperature deviation calibration
Applications
Dry Bath Incubator LB-60DBI is ideal for use in molecular biology, clinical, pharmaceutical and academic laboratories. It supports thermal processing of biological samples such as DNA amplification, enzyme reactions, protein denaturation, and serum incubation.
Block Selection
Block No | Block Capacity |
B1 | 6 mm Test Tube Block (48 wells) |
B2 | 7 mm Test Tube Block (48 wells) |
B3 | 10 mm Test Tube Block (24 wells) |
B4 | 12 mm Test Tube Block (24 wells) |
B5 | 13 mm Test Tube Block (24 wells) |
B6 | 15 mm Test Tube Block (16 wells) |
B7 | 16 mm Test Tube Block (16 wells) |
B8 | 19 mm Test Tube Block (12 wells) |
B9 | 20 mm Test Tube Block (12 wells) |
B10 | 26 mm Test Tube Block (8 wells) |
B11 | 28 mm Test Tube Block (4 wells) |
B12 | 40 mm Test Tube Block (3 wells) |
B13 | 0.2 ml Centrifuge Tube Block (48 wells) |
B14 | 0.5 ml Centrifuge Tube Block (48 wells) |
B15 | 1.5 ml Centrifuge Tube Block (24 wells) |
B16 | 2.0 ml Centrifuge Tube Block (24 wells) |
Frequently asked questions For
1. How can the process be monitored in the Dry Bath Incubator LB-60DBI?
Dry Bath Incubator LB-64DBI features a real-time LCD screen that displays temperature and time settings, allowing continuous monitoring throughout the incubation process.
2. What type of blocks can be used with the Dry Bath Incubator LB-60DBI?
Labotronics Dry Bath Incubator LB-60DBI can use different types of blocks, accommodating tubes of various sizes for easy and flexible sample processing.
3. What are the safety features included in the LB-60DBI?
Dry Bath Incubator LB-60DBI includes built-in over-temperature protection to prevent overheating and automatic fault detection that alerts users to any system errors, ensuring safe and reliable operation during experiments.
4. How fast does the Dry Bath Incubator LB-60DBI reach the set temperature?
Dry Bath Incubator LB-60DBI reaches its set temperature from 25°C to 160°C in 15 minutes or less, allowing for efficient and timely experiment preparation.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
Block Capacity | 1 block |
Temperature Range | -10 °C to 100 °C |
Temperature Control Range | RT-30 °C to 100 °C |
Temperature Accuracy | ≤ ± 0.3°C |
Block capacity | 2 blocks |
Temperature Range | 5 °C to 160 °C |
Temperature Accuracy | ± 0.5°C (at 40°C) ±1°C (at 120 °C) |
Temperature Display Accuracy | 0.1℃ |
Block Capacity | 1 block |
Temperature Range | 0 °C to 100 °C |
Temperature Control Range | RT+5°C to 100 °C |
Heating Lid Temperature Range | OFF to 10℃ |
Block Capacity | 2 blocks |
Temperature Range | 5 to 150 ℃ |
Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
Temperature Display Accuracy | 0.1℃ |
Block Capacity | 1 block |
Temperature Range | 0 °C to 100 °C |
Temperature Control Range | RT +5 °C to 100 °C |
Temperature Accuracy | ≤ ± 0.3°C |
Block Capacity | 4 blocks |
Temperature Range | 0 °C to 100 °C |
Temperature Control Range | RT+5°C to 100 °C |
Temperature Accuracy | ≤ ± 0.3°C |
Block Capacity | 4 blocks |
Temperature Range | 0 °C to 110 °C |
Temperature Control Range | RT +5 °C to 110 °C |
Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
Block Capacity | 4 blocks |
Temperature Range | 0 °C to 100 °C |
Temperature Control Range | RT+5°C to 100 °C |
Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
Block Capacity | 4 blocks |
Temperature Range | 0 °C to 100 °C |
Temperature Control Range | RT+5°C to 100 °C |
Temperature Accuracy | ≤ ± 0.3°C |
Block Capacity | 1 block |
Temperature Range | 5 ℃ to 150 ℃ |
Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
Temperature Display Accuracy | 0.1℃ |
Block Capacity | 4 blocks |
Temperature Range | 5 °C to 130 °C |
Temperature Accuracy | ± 0.5°C (at 40°C) ± 1°C (at 120°C) |
Temperature Display Accuracy | 0.1℃ |
Block Capacity | 1 block |
Temperature Range | -10 °C to 100 °C |
Temperature Control Range | RT -25°C to 100 °C |
Heating Lid Temperature Range | OFF to 10℃ |