Dry Bath Incubator LB-69DBI holds up to 4 blocks and operates from 0 °C to 100 °C temperature range. It is equipped with a user-friendly LCD interface for real-time display of temperature and time settings. It includes interchangeable aluminium blocks, accommodating various sample sizes. Our dry bath incubator features dual independent temperature modes, providing flexible and efficient sample processing.
$ 1300
Download CatalogSpecifications
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ≤ ± 0.3°C (at 37°C) |
| Heating Rate | ≤15min (25℃ to 100℃) |
| Time Range | 1 min to 99 hrs 59 mins / ∞ (continuous operation) |
| Fuse | 250V 3A Ф5×20 |
| Power Consumption | 240 W |
| Power Supply | AC110/220V 50/60Hz |
| Dimensions (W × D × H) | 370 × 254 × 217 mm |
| Weight | 5 kg |
Features
Overheating protection system
Continuous or timed operation
Uniform block temperature
Fast heating rate
High temperature accuracy
Energy-efficient performance
Applications
Dry Bath Incubator LB-69DBI is ideal for use in research labs, clinical settings, and industrial laboratories for sample incubation, enzyme reactions, nucleic acid denaturation, and other temperature-sensitive operations.
Optional Blocks
Block No. | Block Capacity |
B1 | 2.0 ml centrifuge tubes × 15 |
B2 | 1.5 ml centrifuge tubes × 15 |
B3 | 0.5 ml centrifuge tubes × 24 |
B4 | 0.2 ml PCR centrifuge tubes × 32 |
B5 | Φ10 mm tubes × 15 |
B6 | Φ12 mm tubes × 12 |
B7 | Φ15 mm tubes × 8 |
B8 | Φ16 mm tubes × 8 |
Frequently asked questions For Dry Bath Incubator
1. Is the Dry Bath Incubator LB-69DBI capable of continuous heating cycles?
Yes, the Dry Bath Incubator LB-69DBI supports both continuous and pre-timed heating modes depending on experimental requirements.
2. How quickly does the Dry Bath Incubator LB-69DBI reach its maximum temperature?
Dry Bath Incubator LB-69DBI heats from 25 °C to 100 °C in 15 minutes or less, enabling quick setup and efficient progress of temperature-sensitive laboratory procedures.
3. What type of heating technology is used in the Dry Bath Incubator LB-69DBI?
Dry Bath Incubator LB-69DBI uses advanced thermal block heating with aluminium blocks to ensure uniform and accurate temperature distribution.
4. Can the Dry Bath Incubator LB-69DBI operate in multiple thermal zones?
Labotronics Dry Bath Incubator LB-69DBI offers dual independent temperature control for separate blocks, enhancing workflow flexibility.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 5 °C to 130 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ± 1°C (at 120°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature uniformity | ± 0.5°C |
| Block capacity | 1 block |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40 °C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5°C |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT-30 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 2 blocks |
| Temperature Range | 5 to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5 ℃ (40 to 100℃) |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 110 °C |
| Temperature Control Range | RT +5 °C to 110 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block capacity | 2 blocks |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5 °C |
| Block Capacity | 1 block |
| Temperature Range | 5 ℃ to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5℃ (40 to 100℃) ±1℃ (>100℃) |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT -25°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |