Dry Bath Incubator LB-67DBI operates within a temperature range of 0 °C to 100 °C for precise sample incubation. It uses interchangeable blocks, enhancing flexibility for various tube sizes. It features an adjustable heating lid with temperature control for preserving sample integrity. Our dry bath incubator is equipped with a semiconductor-based heating and cooling system, ensuring uniform heat distribution for reliable thermal processing.
$ 1675
Download CatalogSpecifications
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Heating Lid Temperature Accuracy | ≤±0.5℃ |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ≤ ± 0.3°C (at 37°C) |
| Heating Rate | ≤12min (25℃ to 100℃) |
| Heating Lid Heating Rate | ≤10min (25℃ to 100℃) |
| Time Range | 1 sec to 99 hrs 59 mins / ∞ (continuous operation) |
| Fuse | 250V 3A Ф5×20 |
| Power Consumption | 150 W |
| Power Supply | AC110/220V 50/60Hz |
| Dimensions (W × D × H) | 300 × 200 × 210 mm |
| Weight | 4 kg |
Features
Auto restart function
Over-temperature protection
LCD screen with real-time display
Adjustable timer
Multi-point operation mode
Integrated block sensor
Applications
Dry Bath Incubator LB-67DBI is ideal for clinical, research, pharmaceutical, and molecular biology laboratories. It is used for sample incubation, nucleic acid denaturation, serum coagulation, and other temperature-sensitive processes.
Block Selection
Block No. | Block Capacity (RT – 25 ℃ to 100 ℃) |
B1 | 2.0 ml centrifuge tubes × 35 |
B2 | 1.5 ml centrifuge tubes × 35 |
B3 | 0.5 ml centrifuge tubes × 54 |
B4 | 0.2 ml PCR centrifuge tubes × 96 |
B5 | 0.2 ml Elisa plate × 96 |
Frequently asked questions For Dry Bath Incubator
1. Can the Dry Bath Incubator LB-67DBI maintain uniform heating across the block?
Yes, the Dry Bath Incubator LB-67DBI delivers consistent temperature across the entire block with a uniformity of ±0.3 °C at 37 °C, minimizing variations between sample positions.
2. What is the purpose of the heating lid in Dry Bath Incubator LB-67DBI?
Dry Bath Incubator LB-67DBI uses a heating lid to prevent condensation on tube surfaces and stabilize the internal environment, supporting consistent thermal performance.
3. What safety features are integrated into the Dry Bath Incubator LB-67DBI?
Dry Bath Incubator LB-67DBI includes built-in over-temperature protection and an auto-restart function, ensuring safe and uninterrupted operation.
4. Is the Dry Bath Incubator LB-67DBI suitable for portable bench-top applications?
Dry Bath Incubator LB-67DBI is designed with a compact footprint and weighs only 4 kg, allowing easy placement and portability for bench-top laboratory use.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT -25°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block Capacity | 4 blocks |
| Temperature Range | 5 °C to 130 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ± 1°C (at 120°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature uniformity | ± 0.5°C |
| Block capacity | 1 block |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40 °C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5°C |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 110 °C |
| Temperature Control Range | RT +5 °C to 110 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 2 blocks |
| Temperature Range | 5 to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5 ℃ (40 to 100℃) |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block capacity | 2 blocks |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5 °C |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT-30 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | 5 ℃ to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5℃ (40 to 100℃) ±1℃ (>100℃) |