Dry Bath Incubator LB-64DBI holds up to 4 blocks and offers precise dry heating from 0 °C to 110 °C. It features a real-time LCD screen for clear monitoring of temperature and time during incubation. It includes four independently controlled heating zones, providing flexible and efficient operation. Our dry bath incubator is equipped with a built-in calibration function, ensuring temperature accuracy.
$ 1350
Download CatalogSpecifications
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 110 °C |
| Temperature Control Range | RT +5 °C to 110 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ≤ ± 0.3°C (at 37°C) |
| Heating Rate | ≤20min( 25℃ to 110℃) |
| Time Range | 1 min to 99 hrs 59 mins / ∞ (continuous operation) |
| Fuse | 250V 3A Φ5×20 |
| Power Consumption | 500 W |
| Power Supply | AC220/110V 50/60Hz |
| Dimensions (W × D × H) | 370 × 254 × 228 mm |
| Weight | 8 kg |
Features
Overheating protection
Adjustable timer
Easy block replacement
Protective transparent lid
Automatic and programmable heating
Applications
Dry Bath Incubator LB-64DBI is used in research labs, clinical diagnostics, biotechnology, and pharmaceutical facilities. It supports sample incubation, enzyme reactions, DNA amplification, serum coagulation, and nucleic acid denaturation.
Block Selection
Block No | Block Capacity |
B1 | 6 mm Test Tube Block (48 wells) |
B2 | 7 mm Test Tube Block (48 wells) |
B3 | 10 mm Test Tube Block (24 wells) |
B4 | 12 mm Test Tube Block (24 wells) |
B5 | 13 mm Test Tube Block (24 wells) |
B6 | 15 mm Test Tube Block (16 wells) |
B7 | 16 mm Test Tube Block (16 wells) |
B8 | 19 mm Test Tube Block (12 wells) |
B9 | 20 mm Test Tube Block (12 wells) |
B10 | 26 mm Test Tube Block (8 wells) |
B11 | 28 mm Test Tube Block (4 wells) |
B12 | 40 mm Test Tube Block (3 wells) |
B13 | 0.2 ml Centrifuge Tube Block (48 wells) |
B14 | 0.5 ml Centrifuge Tube Block (48 wells) |
B15 | 1.5 ml Centrifuge Tube Block (24 wells) |
B16 | 2.0 ml Centrifuge Tube Block (24 wells) |
B17 | 0.2 ml PCR plate (96 wells) |
B18 | 0.2 ml Elisa plate (96 wells) |
Frequently asked questions For Dry Bath Incubator
1. Can the Dry Bath Incubator LB-64DBI perform heating based on preset conditions?
Yes, the Dry Bath Incubator LB-64DBI supports both automatic and programmable heating functions for flexible operation.
2. What are the safety features included in the LB-64DBI?
Dry Bath Incubator LB-64DBI includes built-in over-temperature protection to prevent overheating and automatic fault detection that alerts users to any system errors, ensuring safe and reliable operation during experiments.
3. Does the Dry Bath Incubator LB-64DBI allow separate temperature control for each block?
Yes, the Dry Bath Incubator LB-64DBI features four independently controlled heating zones, allowing simultaneous incubation of different samples under separate conditions.
4. Does the Dry Bath Incubator LB-64DBI support incubation of serum samples?
Yes, the Dry Bath Incubator LB-64DBI supports incubation of serum and other biological samples such as enzymes, nucleic acids, and proteins requiring precise temperature control.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT-30 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 5 °C to 130 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ± 1°C (at 120°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature uniformity | ± 0.5°C |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block capacity | 1 block |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40 °C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5°C |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 1 block |
| Temperature Range | 5 ℃ to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5℃ (40 to 100℃) ±1℃ (>100℃) |
| Block Capacity | 2 blocks |
| Temperature Range | 5 to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Temperature Stability | ±0.5 ℃ (40 to 100℃) |
| Block capacity | 2 blocks |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ± 0.5 °C |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT -25°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Temperature Display Accuracy | 0.1℃ |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.com
WhatsApp: +1 579 401 0534